Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 204 CORPORATE TOWERS 2ND FLOOR 85 A ZAMRUDPUR NEW DELHI SOUTH DELHI DELHI 110048 | SOUTH DELHI | DELHI | 110048 | Admitted-Finance |
| 5 | Rejected-Technical F PRABENDRA KUMAR F 275 SECT 36 GREATER NOIDA GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | Rejected-Technical Not Suitbale |
Tender Value
Refer Docs
Closing Date
19 Feb 2025, 2:00 pmClosed
DGM Purchase
BHARAT ELECTRONICS LIMITED JALAHALLI POST BENGALURU 560 013
Supply Installation, Testing andCommissioning of Air Washer System at EW and A Building
2025_BEL_96601_1
BG/ES9/2600814117
Open Tender
Miscellaneous Goods
Supply
BEL Banglore
AS Per Tender
5 documents required · 5 mandatory
₹0
Exempted
11 Mar 2025
30 Jan 2025
20 Feb 2025
30 Jan 2025
19 Feb 2025
30 Jan 2025
Amount
SUPPLY OF AIR WASHER SYSTEM AT EW&A BUILDING
Supply of Double skinned package type Air Washers of 15000 CFM and external static pressure not less than 50 mm made of hollow aluminium section , PUF insulation ,complete with inlet filters, cel-dek/cellulose based media,distribution system consists of PVC pipes, FRP distributor, PVC mist eliminator, centrifugal blower & motor,drive, stainless steel tank, brass screen, GI casing, etc. all as specified and/or directed etc., complete. Note: The existing mono block pump set with isolation valves in suction and discharge lines, NRV in pump discharge lines, Y strainer in pump common suction lines, shall be used for the commissioning of the system
Supply of volume control dampers (VCD) for ducts made of GI sheet of thickness not less than 18 G including fittings, gaskets, nuts, bolts etc.,all as specified and / or directed etc., complete
Supply of Fusible link fire dampers of minimum 120 minute rating made of GI sheet of thickness not less than 16 G complete with GI casing, GI Blades 150mm, spindles, bushes including fittings, gaskets, nuts.bolts etc.,all as specified and / or directed etc., complete.
INSTALLATION, TESTING & COMMISSIONING OF AIR WASHER SYSTEM AT EW&A BUILDING
Erection, Testing and Commissioning of Double skinned package type Air Washers of 15000 CFM and external static pressure not less than 50 mm made of hollow aluminium section , PUF insulation ,complete with inlet filters, cel-dek/cellulose based media,distribution system consists of PVC pipes, FRP distributor, PVC mist eliminator, centrifugal blower & motor,drive, stainless steel tank, brass screen, GI casing, etc. all as specified and/or directed etc., complete. Note: The existing mono block pump set with isolation valves in suction and discharge lines, NRV in pump discharge lines, Y strainer in pump common suction lines, shall be used for the commissioning of the system
Erection, Testing and Commissioning of volume control dampers (VCD) for ducts made of GI sheet of thickness not less than 18 G including fittings, gaskets, nuts, bolts etc.,all as specified and / or directed etc., complete
Erection, Testing and Commissioning of Fusible link fire dampers of minimum 120 minute rating made of GI sheet of thickness not less than 16 G complete with GI casing, GI Blades 150mm, spindles, bushes including fittings, gaskets, nuts.bolts etc.,all as specified and / or directed etc., complete.
AIRCON REF PVT. LTD. (BID ID -414375)
LAKSHMI MEP INFRAH P LTD (BID ID -414185)
COASTAL SALES AND SERVICE (BID ID -414336)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .