Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99,000Accepted-Finance | ₹99,000 | L1 | Accepted-Finance L1 |
| 2 | L2₹1.2 LRejected-Finance 123 716 GADARIAN PURWA KANPUR NAGAR UTTAR PRADESH 208023 UDYAM UP 43 0039845 | KANPUR NAGAR | UTTAR PRADESH | 208023 | ₹1.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹1.3 LRejected-Finance | ₹1.3 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | M/S SUPER TRADING COMPANY L2 | RAJEEV TIWARI L1 | M/s Radha Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantalling of old Control Panel and Relay Panel instailed in BCU room by opening of cable connections. earthing M.S. flats, nut-bolts etc. Including safe disconnection of 132 KV Itwa-Shohrathgarh TSS Bay and cable loop panel to panel cables connection ete. & making of new loop connection (temporary) for other healthyness of running control panels as required. The work also includes indentification of the control cables by providing suitable ferrules etc. | 2 | No | 20,000 ₹40,000 | 15,000 ₹30,000 | 18,000 ₹36,000 |
| 2.00 | Shifting of duplex type 132 KV Feeder C&R panel from Store to BCU room of 132 KV S/S Itwa by Crane with all cost of men. T&P Consumables etc. | 1 | No | 15,000 ₹15,000 | 4,000 ₹4,000 | 4,500 ₹4,500 |
| 3.00 | Installation of new Control & Relay Panel in BCU room. Its grouting & earthing and termination of control cables in control & relay panel as per cable schedule plan including providing & fixing of cable gland of appropriate sizes and ferrules etc, with all other associated works as per technical specification including safe reconnection of 132 KV Itwa-Shohrathgarh TSS Bay and panel to panel cables connection etc. The work also includes control cables connections as required between control panels looping the commissioning of the Control & Relay Panel shall be done jointly with T&C wing including troubleshooting as needed/necessary. Also inter connection diagram as per new C&R Panel shall be submitted and got approved by the concerned supervising engineer/incharge before start of the work. After completion of work schedule shall be provided as executed mentioning Cable Tag. TBNo. & ferrules for C&R Panel. | 1 | No | 20,000 ₹20,000 | 21,000 ₹21,000 | 21,000 ₹21,000 |
| 4.00 | Shifting of 132 KV Feeder control & relay panel (Old & Used) from BCU room to Store of 132 KV S/S Itwa with the help of labour, rope, crane with cost of men, T&P consumable etc. | 2 | No | 16,000 ₹32,000 | 2,000 ₹4,000 | 4,500 ₹9,000 |
| 5.00 | Commissioning, configuration and testing of new installed numarical relay. Testing must necessarily be carried out with the help of electronic secondary relay testing kit. All the required tests related to above Distance protection relay should be done exactly in accordence with the electrical norms and standardand as per the guidance of'T&C wing. | 1 | No | 10,000 ₹10,000 | 40,000 ₹40,000 | 57,000 ₹57,000 |
Tender Value
Refer Docs
EMD Value
₹1,500
Closing Date
21 May 2026, 4:00 pmClosed
EXECUTIVE ENGINEER
132 KV SUB STATION NAUGARH
REPLACEMENT OF 02 NO. CONTROL PANEL AND RELAY PANEL FOR 132 KV ITWA-SHOHRATHGARH TSS LINE AT 132 KV SUB STATION ITWA
2026_UPTCL_1147543_1
E-tender no.04-2026-27
Open Tender
Electrical Works
30 days
132 KV SUB STATION ITWA
AS PER TENDER
2 documents required · 2 mandatory
₹590
ELECTRICITY TRANSMISSION DIVISION II BASTI
₹1,500
4 Jul 2026
12 May 2026
22 May 2026
12 May 2026
21 May 2026
12 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantalling of old Control Panel and Relay Panel instailed in BCU room by opening of cable connections. earthing M.S. flats, nut-bolts etc. Including safe disconnection of 132 KV Itwa-Shohrathgarh TSS Bay and cable loop panel to panel cables connection ete. & making of new loop connection (temporary) for other healthyness of running control panels as required. The work also includes indentification of the control cables by providing suitable ferrules etc. | 2 | No | - | - |
| 2 | Shifting of duplex type 132 KV Feeder C&R panel from Store to BCU room of 132 KV S/S Itwa by Crane with all cost of men. T&P Consumables etc. | 1 | No | - | - |
| 3 | Installation of new Control & Relay Panel in BCU room. Its grouting & earthing and termination of control cables in control & relay panel as per cable schedule plan including providing & fixing of cable gland of appropriate sizes and ferrules etc, with all other associated works as per technical specification including safe reconnection of 132 KV Itwa-Shohrathgarh TSS Bay and panel to panel cables connection etc. The work also includes control cables connections as required between control panels looping the commissioning of the Control & Relay Panel shall be done jointly with T&C wing including troubleshooting as needed/necessary. Also inter connection diagram as per new C&R Panel shall be submitted and got approved by the concerned supervising engineer/incharge before start of the work. After completion of work schedule shall be provided as executed mentioning Cable Tag. TBNo. & ferrules for C&R Panel. | 1 | No | - | - |
| 4 | Shifting of 132 KV Feeder control & relay panel (Old & Used) from BCU room to Store of 132 KV S/S Itwa with the help of labour, rope, crane with cost of men, T&P consumable etc. | 2 | No | - | - |
| 5 | Commissioning, configuration and testing of new installed numarical relay. Testing must necessarily be carried out with the help of electronic secondary relay testing kit. All the required tests related to above Distance protection relay should be done exactly in accordence with the electrical norms and standardand as per the guidance of'T&C wing. | 1 | No | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
TECHNICALDOC04.pdf
Tender Documents • 5.31 MB
BOQ_2146860.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid