Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 90 A 2ND FLOOR MAIN ROAD AMRIT PURI B REGD EAST OF KAILASH SOUTH DELHI 110065 | DELHI | SOUTH DELHI | DELHI | 110065 | L1 | Accepted-AOC As per NIT | |
| 2 | L2₹24.8 L+₹6.9 L (38.7%)Rejected-Finance B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L2 | Rejected-Finance As per NIT | |
| 3 | Rejected-Technical | - | Rejected-Technical As per NIT | |
| 4 | Rejected-Technical 111 A POCKET IV DDA FLATS MAYUR VIHAR PHASE 1 DELHI 110091 | EAST | DELHI | 110091 | - | Rejected-Technical As per NIT |
Tender Value
₹28.3 L
EMD Value
₹56,611
Closing Date
18 Mar 2024, 11:00 amClosed
Sh. Sudhhir Kumar
Old Zonal MCD Office, Vishal Enclave, Rajouri Garden, West Delhi-110027.
SITC of Online Monitoring System (OLMS) for STP/ETP in Mata Gujri Hospital, Tilak Nagar under West Zone.
2024_MCD_190901_2
EE/Elect/WZ/2023-24/106
Open Tender
Electrical Works
Item Rate
60 days
West Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹56,611
24 Dec 2024
12 Mar 2024
18 Mar 2024
12 Mar 2024
18 Mar 2024
12 Mar 2024
Amount
Approved RAte
OD28194/2023-2024:S.I.T.C of the Online Continuous Effluent Quality Monitoring Analyzer to measure continuous COD, BOD, TSS & pH with single analyzer with ss304/ 316 housing type sensors. System must Operates &analyzes every minute without any need of hazardous reagents, chemicals, maintenance, consumables and low calibration requirements. USEPA, TUV, CEPA approved and consented for use in waste-water applications. Direct measurement for each parameter with direct parameter calibration, validation & analysis. IP68 submersible sensors for real time analysis & no sample pumping and sample conditioning required. No interference from high chloride, in organics, colour, TSS & Turbidity. Operates in full spectrum with UV & Visible double beam spectrophotometry. Multi-point calibration with automatic matrix change adaptability featured onboard. measuring principle: UV-Vis spectrometry over the total range (200-750 nm). web server on board - IoT enabled, no user software is needed to configure the probe. Communicates directly with your mobile device via Bluetooth or WLAN. 8 GB onboard memory - capacity for logging data for 5 years i.e., during AMC / CMC service. System should have fast measurement interval - every 10 seconds possible. It also should be power efficient - sleep mode for low energy consumption. Sensors should be factory pre calibrated, local multi-point calibration possible with facility of automatic cleaning with compressed air with Hardware for Data Transmission, IOT Device to connect Modbus signal of OCEMS: High-end IoT (Internet of Things) terminal based on an PC, IP65 with widescreen colour graphical display (9”) and touch screen. sensor and station management of up to 64 parameters: automatic cleaning, data logging, sample & calibration including history and multipoint calibration, sensor function check, user management and easy data transfer via USB stick. (a) Multi parameter measuring Sensor and Terminal for connecting up to 18 intelligent sensors scope including 8 analog input/outputs (4 inputs & 4 outputs) (0/4 – 20 Ma), wide range power supply optical COD, BOD & TSS probes with spectral processing of the uv-vis range, for the measurement of outlet / effluent of STP/ETP of Mata Gujri Hospital with integrated and automatic with self-cleaning etc. complete as required. (b) Supply of robust digital pH / ORP Sensor measuring principle: unique, non-porous / non-leaking combined reference electrode for technically unrivalled and consistent pH performance. plug & measure, ideal for waste water; pH sensor to monitors pH; factory pre calibrated; mounting and measurement directly in the media (InSite) or in a flow cell, operation via asked data terminals & OEM software. (c) Sensor Adapter cable for all intelligent sensors with IP 68 water poof connection with intelligent sensor Net System, Cable length 100 meters (minimum) etc. complete as required (d) A Compliance report should be submitted after successful completion of work by DPCC authorised person
OD28193/2023-2024:Comprehensive maintenance with all material and accessories of online Continuous Effluent Measurement analyzer and provide services of data transmission to CPCB and DPCC server during 5 years after commissioning of work and also agency provide 3 months trail period (Including fortnightly reports will be submitted by agency during 5 years of service period). By Providing GSM 3G / 4G / 5G or other available communication mobile network with modem compatible at relevant time. Including network charges for 1 + 5 years after commissioning of work free three months trial months
Aaxis Nano technologies Pvt. Ltd.
Bidder Name
Nevco Engineers Pvt. Ltd.
Aaxis Nano technologies Pvt. Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .