Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-Finance | L1 | Accepted-Finance As per financial evaluation | |
| 2 | L2₹9.0 L+₹2.1 L (29.5%)Rejected-Finance | L2 | Rejected-Finance As per financial evaluation | |
| 3 | Rejected-Technical | - | Rejected-Technical As per technical Evaluation | |
| 4 | Rejected-Technical | - | Rejected-Technical As per technical Evaluation |
Tender Value
₹8.2 L
EMD Value
₹20,555
Closing Date
25 Jul 2022, 3:00 pmClosed
Superintending Archaeologist
J C road anta ghat
As per tender document
2022_ASI_698622_1
T-1/100/Jun/22/13176817/Con
Open Tender
Job Works
Works
180 days
patna
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
SA ASI
₹20,555
Yes
3 Oct 2022
4 Jul 2022
26 Jul 2022
5 Jul 2022
25 Jul 2022
5 Jul 2022
Amount
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of Rubbish to the dumping ground within 50 meters lead.
12 mm Plastering with 1:6 Cement Sand Mortar mix with all complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. Complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade compete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge etc.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt- 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mmouter diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm center to center& 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizeDerived from natural sources).
Provision for Providing steel in R.C.C work with all works. total work 0.765x7800 kg= 5967kg steel required for in RCC work 5969x0.0125= 74.58 kg.
Providing and fixing Panelled or Panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding Panelling which will be paid for separately, all complete as per direction of Engineer-in charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters.
Provision for fiber door for Kitchen & Bathroom including all fitting charges and repair of 4 no. doors and 4 no. chockeths and 2 no. windows
Provision for sanitary fitting with all completed (Wash Basin)
Indian Pan
Urinal Pan
European W.C (Jaguar/Somany)
West Pipe
Piller cock
Urinal WT Pipe
Angle Stop Cock
Connection Pipe
C.P Base
Angle Cock
Towel stand and Hanger
Fitting Charges (Drinking water, Toilet Block and baby care room )
Electrical work in Rest Room, Dining Room, Kitchen and Toilet Block including wiring and fitting charges with all completed. [Copper Wire (1.5 mm)]
Copper Wire (2.5 mm)
Copper Wire (4 mm)
PVC Pipe ¾
PVC Pipe 1”
15 amp switch
5 amp switch
15 amp socket
5 amp socket
Juction
PVC Board (4”× 4”)
PVC Board (6”× 8”)
PVC Board (10”× 12”)
LED and Tube Light
Electrician and labor fitting charges
RADHA MOHAN SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .