Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.9 LAccepted-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹95.1 L+₹97,684.35 (1.04%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹97.7 L+₹3.7 L (3.90%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹98.1 L+₹4.0 L (4.24%)Rejected-AOC 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹98.3 L+₹4.2 L (4.48%)Rejected-AOC 1798 SECTOR 60 SAS NAGAR MOHALI 144102 PB | MOHALI | MOHALI | PUNJAB | 144102 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
Closing Date
28 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
ADDITION/ALTERATION TO AVOINICS LAB AT AF STATION ADAMPUR
2022_MES_514167_1
CWE/AF CHD/ADM/T-38/2021-2022
Open Tender
Civil Works
Item Rate
120 days
Adampur
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Adampur
Exempted
4 Apr 2022
17 Mar 2022
30 Mar 2022
17 Mar 2022
28 Mar 2022
22 Mar 2022
60 days
Amount
Building Work
Taking down chowkhats or frames, exceeding 1.5 Sqm but not exceeding 4.0 Sqm each and removal, including making good the disturbed surface in CM(1:4) and finishing as per existing specifications and removal of debris outside MOD land, complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame), not exceeding 1.5 Sqm each and removal, including making good the disturbed surface in CM(1:4) and finishing as per existing specifications and removal of debris outside MOD land, complete all as specified and directed.
Surface excavation in soft/loose soil not exceeding 30 Cm deep and averaging 15 Cm and getting out complete, all as specified.
Material and labour for plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
Material and labour for RCC M-25 using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material and labour for RCC M-25 using 20 mm graded stone aggregate as in foundations including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
Taking down existing water proofing treatment (any no of layers) including cement mortar bedding layer, cleaning the surface and removing rubbish off the premises i.e MOD land, complete all specified and directed.
Material and labour for cleanig the new or old concrete surface and applying water proofing treatment to RCC roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30litre/Sqm including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60Kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps (100mm side lap and 150 mm end lap ) & joints with flame (by torch flame application) all as per manufacturer’s instructions, complete all as specified and directed.
Material and Labour for 40mm thick brick tiles laid over and including 15mm thick cement screed bed in CM (1:6) using grey cement and grouted and pointed flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, laid on concrete roof, complete all specified and directed.
Material and labour for RCC M-25 using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Material and labour for RCC M-25 using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
Material and Labour for TMT steel bars, 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Material and Labour for mild steel TMT bars 8 mm dia and over upto 10 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified.
Material and labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc., flat rough finished concrete surfaces, complete all as specified and directed.
Material and labour for Formwork to concrete foundations, footings, bases of columns, raft & raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work, vertical or to batter, flat rough finished concrete surfaces complete all as specified and directed.
Material and Labour for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, also splays between floors and beams, etc for rough finish flat surface, complete all as specified and as directed
Material and labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; flat rough finished concrete surfaces, not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed.
Material and labour for brickwork with using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
Material and labour for rendering 15 mm thick in cement mortar (1:4), on brick/concrete surfaces of walls, finished even smooth without using extra cement , complete all as specified and directed.
Material and labour for rendering 10 mm thick in ceiling in cement mortar (1:3), on fair faces of brick/concrete surfaces of walls, finished even smooth without using extra cement , complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of 1st quality oil bound distemper (oil emulsion) over and including a coat of alkali resistance primer, complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of ceiling/ ceiling boards and applying two coats of 1st quality oil bound distemper (oil emulsion) over and including a coat of alkali resistance primer, complete all as specified and directed.
Removing of surplus soil / excavated material to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed complete all as specified.
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including removal of debries out of defence land complete all as specified and directed.
Material and labour for first quality joint less vitrified ceramic Ivory coloured tiles, 10 mm thick, (square/rectangular), of approved shade and pattern, of size 600 mm x 600 mm, as in floors etc, set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white cement mixed with pigment or coloured cement to match the shade of tiles, including screed bed or bedding layer of cement mortar 1:6, 15 mm thick, over 25 mm thick PCC 1:2:4 type B-0, complete all as specified and directed.
Material and labour for 75 mm thick Plain cement concrete (1:3:6), Type C-1, using 20 mm graded stone aggregate as in plinth protection, finished the surface even and fair, with joints at corners and @ 3 metres c/c filled with mastic mortar, complete all as specified.
Supply and fixing asbestos cement decorative type building boards, 4 mm thick of size 60 cm x 60 cm as in ceiling, including anodised aluminium snap grid frame work 605 mm x 605 mm for false ceiling and hangers 6 mm dia GI (upto 1200 mm length) with level adjusting mechanism, fixed to roof slabs by means of ceilling cleats made out of GI flat 40 mm x 3 mm, 60 mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed.
Supply and fixing Powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc., with minimum thickness of powder coating 50 micron, complete shall as specified.
Supply and fixing Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m, with minimum thickness of powder coating 50 micron, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos), suitable handle (2 Nos.) complete shall as specified and directed.
Supply and fixing Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m, with minimum thickness of powder coating 50 micron, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos), suitable handle (2 Nos.) complete shall as specified and directed.
Supply and fixing plain sheet glass 4.5 mm thick, ordinary quality, not exceeding 0.50 Sqm each pane, and glazing with oil putty and securing pins, complete all as specified and directed.
Supply and fixing Aluminium anodized grills of type DG 117 of make Deco-grill, fixed to window opening, complete shall as specified and directed.
Supply and fixing solar control film 25 micron thick, reflective type, sticked to glass panes as per instructions of manufacturer, complete shall as specified and directed.
Supply and fixing Solid PVC Wall Lining consisting of 5 mm thick printed colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and as shown in drawing in SSR Part I.
Material and labour for mild steel as in framed work of doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing similar work conforming to Fe-290 Grade E-165, complete all as specified and directed.
Material and Labour for collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
Supply and Fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
Material and labour, applying two coats of synthetic enamel paint over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Material and labour for complete removal of existing treatment of old decorated plastered surfaces of walls, pillars, cornices and applying two coats of Acrylic weather coat emulsion paint on walls/ceiling/facias/ramp surfaces etc in disruptive/camouflaging pattern in four shades, as per sample approved by GE, for building of height upto 7.50 metre, over and including a coat of water based primer complete all as specified and directed. Note- (i) The rate quoted by contractor is deemed to include preparation of surfaces and necessary scaffolding for painting upto required height.
Supply and fixing steel rolling shutter, gear operated type with bevel gear box and crank handle, 1.00 mm thick, without ball bearing, including top cover, anchoring rod, hasp and staple and one shop coat primer, erected in position as indicated, complete all as specified and directed.
Material and labour for 50 mm thick PCC flooring with cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate finished surface even and smooth without using extra cement complete all as specified and directed
Material and Labour for Endura vitrified Paving tiles 10 mm thick (coloured), area not exceeding 0.18 sqm in each tile, set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white cement mixed with pigment or coloured cement to match the shade of tiles, including 15 mm thick screed bed in cement mortar (1:4) with neat cement and pointed in grey cement mixed with pigment to match the shade of tiles, complete all as specified and directed.
Removing of dismantled materials/debries etc to a distance exceeding 2.00 Kilometre but not exceeding 5.00 Kilometre and depositing where directed complete all as specified.
Excavating in post holes ( or similar holes) in soft/loose soil each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 metres and making good surface, complete all as specified and directed.
Supply and fixing roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. with rolled mild steel FE-290 Gde E-165, complete all as specified and directed.
Supply and fixing pre-painted plain galvalume aluminium zinc coating GI based corrugated sheets 0.50 mm thick of approved colour, having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws, complete all as specified and directed.
Material and Labour for PCC (1:2:4) type B-1, using 20 mm graded crushed stone aggregates, as in bed block of hold fast, coping, including weathering, slightly rounded or chamfered angle and throating, including necessary form work, complete all as specified and directed.
Material and labour for Factory Made Machine pressed precast concrete interlocking paver block any shape and size as approved confirming to IS 15658-2006 of 80 mm thickess, M-40 grade, with grey cement and pigment laid over,complete all as specified and directed.
Material and labour for fine sand filling under floor in layers not exceeding 25 cm in each layer, including watering and well ramming complete all as specified.
Supply and fixing Towel rail 600 mm long, 20 mm dia, of PTMT (Minimum weight 190 gms) fixed with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed.
Supply and fixing in repair vitreous china wash down water closet (pedestal pattern) white pedestal pan and trap, including connection to drain ( or out going pipe ) and to flushing pipe, antisyphonage pipe, with jet, plastic water closet seat cover white , closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device etc complete all as specified.
Supply and fixing in repair, vitereous china half stall type white urinal including providing fixing plugs, bedding urinals against wall in cement mortar 1:2, securing urinal to plug with and including 60 mm long brass screws, pointing arround urinal back in cement, including waste coupling (PTMT) half or full threaded suitable for urinals, grating, union for discharge pipe, spreader, 40 mm dia PVC waste pipe upto floor trap, 5 ltr capacity automatic flushing cistern with brackets, flush pipe, union for discharge pipe complete all as specified and as directed.
Supply and fixing Solid PVC Door Frame of size 50 mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with M.S. Square tube, as per specification & drawing in SSR Part-II, in opening, complete all as specified and directed.
Supply and fixing factory made pre-laminated PVC door shutter (conforming to IS-4020) 30 mm thick consisting of frame made out of M.S. tubes of 19 gauge thickness & size of stiles, top rail, bottom rails & lock rail all as per shown on drawings in SSR 2010 Pt II, M.S. frame shall have a coat of steel primer of approved make & manufacturer, MS frame covered with 5mm thick heat moulded pre-laminated PVC ‘C’ channel of size 30mm thick, 70mm width out of which 50mm shall be flat & 20mm shall be tapered in 45degree on the either side forming stiles and 5mm thick, 95mm wide pre-laminated PVC sheet out of which 75mm shall be flat and 20mm shall be tapered at 45 degree on the inner side to form top rail & bottom rail and 155mm pre-laminated sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom & lock rail shall be provided on either side of panel. 10mm (5mmx2mm) thick, 20mm wide cross PVC sheet shall be provided as gap inserted to top rail and bottom rail; Paneling of 5mm thick prelam PVC sheet to be fitted with M.S. frame welded/sealed to the stiles & rails with 5mm+2mm thickx15mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of "C" channel using PVC solvent adhesive, complete all as specified and directed.
Material and labour for cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and debris outside MOD land, complete all as specified and directed
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
Material and labour for 300 mm thick ready mixed concrete (RMC) pavement quality concrete (PQC) as per design mix (as per IRC 44 specifications) using graded crushed stone aggregate, having minimum field flexural strength of 45 Kg/Sq cm in pavement, ( min cement content shall be 400 Kg / cum using OPC 43 gde) and super-plastisizer, if required, laid to level, gradient and camber, spread, paved, campacted & finished including belting & brooming complete all as specified and directed. Note:- (i) In the event of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same. (ii) All expansion joints to be deducted and all dummy/construction joints to be considered for measurement purpose.
Material and labour for laying 400 micron thick HDPE polythene film including all necessary cutting, with overlaps not less than 300 mm on side and ends, including applying tack coat with bitumen VG-10 grade @ 2.5 Kg/10 Sqm, complete all as specified and directed.
Material and labour for forming contraction (Dummy) joints ( using dimond cutter ) upto 1/3 of depth of slab (100 x 8 mm) and top 25 mm x 8 mm wide to receive polyurethane joint sealing compound and leaving 3 mm at top, providing polethene backup rod of suitable dia and sealed with polyurethane sealent, priming the sides with approved primer complete all as specified and directed.
Material and labour for forming construction joints 25 mm deep x 8 mm wide, providing polythene backup rod of suitable dia and sealed with polyurethane sealent compound (min depth of sealent compound 12 mm) , priming the sides with approved primer, complete all as specified and directed.
Material and labour for rendering 15 mm thick in cement mortar (1:6), on brick/concrete surfaces of walls, finished even and smooth, complete all as specified and directed.
INTERNAL ELECRIFICATION WORK
Supply and laying Cable Bridge straight type, 2 channel, 1000 mm x 250 mm x 48 mm, for cable size 10/2.5 sq.mm, 3 core with following features:- 1.MOC: SBR/NBR rubber material. 2.Dimension: 1000 mm x250 mm x48 mm (LxWxH). 3.Channel: 2 Channel of size 28 mm x30mm. 4.Load carrying capacity: 9 Tonne. 5.Surface: Non-slip surface. 6.Color: Black/yellow warning colors 7.Type: Straight. 8.Max speed withstand capability: 10km/Hr. 9.High self-weight, very stable coating. 10.Dielectric strength: Non conductive and up to 110 KV of dielectric strength. 11.Chemical property: Resistant to acids and alkalis. 12.Environmental property: UV and heat resistant. 13.Make: Hensel Cat No. 39870020 or equivalent in Rittal. 14.Warranty and test certificates shall be supplied with the material, complete all as specified and directed. Make :Hensel/Rittal or equivalent
Supply, installation, commissioning and testing polycarbonate ASTA CPRI approved OEM made MCCB DB. The MCCB DB shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES with transparant door. The DB which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4. The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE only and also share panel assembling details by OEM, channel partner or sister concered assembly shall not be accepted. DEGREE OF INGRESS PROTECTION shall be IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of ployurethane. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of plycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satsifactory:- temperature rise, dielectric properties , short circuit withstand current- rated peak & short time withstand current and rated conditional short circuit current, effectiveness of protective circuits. Each board shall have individual routine test report of the manufacturer. The DB shall pass glow wire test at 960ºC in accordance with IEC 60695-2-11 (flame retardant and self-extinguishing, complete all as specified and directed. Make Hensel/Rittal/Emitter/Schneider/Abb. Incomer :- Main MCCB 63 A, 4 pole, breaking capacity 10KA, thermal and magnetic released spreader links & extended rotary handle -01 No.
Supply, Installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made SPN DB. MCB DB shall be with Transparant Door. The SPN DB shall be Extandable with detachable provision. The SPN DB shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES. SPN distribution board shall be shock proof, safe, IP66 according to IEC 60529 (EN 60529), weather proof, Corrosion free, Acid & Chemical Resistant, Impact resistant, Ultra Violet resistant according to IEC 61439-1 , made of halogen & Silicone free recyclable material, internally embedded gasket with provision for cable entry through integrated flanges top and bottom with removable side walls, Impact strength Ik 08 (5 joules) in accordance with DIN EN 50102, shall withstand Glow wire test IEC60695-2-11-960°C, shall be flame retardant, Self Extinguishing, UL subject 94, V2 , totally insulated, type tested according to IEC 61439, flame retardant and self-extinguishing. SPN DB shall be provided with 10 Nos MCB SP 32 Amp 10 KA with Incomer MCB SPN 63Amp 10KA. DB Suppiler shall submit all cerification as mentioned above,complete all as specified and directed.
Supply, Installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made SPN DB. MCB DB shall be with Transparant Door. The SPN DB shall have Extandable with detachable provision. The SPN DB shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES. SPN distribution board shall be shock proof, safe, IP66 according to IEC 60529 (EN 60529), weather proof, Corrosion free, Acid & Chemical Resistant, Impact resistant, Ultra Violet resistant according to IEC 61439-1 , made of halogen & Silicone free recyclable material, internally embedded gasket with provision for cable entry through integrated flanges top and bottom with removable side walls, Impact strength Ik 08 (5 joules) in accordance with DINEN 50102, shall withstand Glow wire test IEC60695-2-11-960°C, shall be flame retardant, Self Extinguishing, UL subject 94, V2 , totally insulated, type tested according to IEC 61439. flame retardant and self-extinguishing. SPN DB shall be provided with with 4 Nos MCB SP 32 Amp 10 KA with Incomer MCB SPN 63 Amp 10KA. DB Suppiler sall submit all cerification as mentioned above complete all as specified and directed. Make- Hensel/Rittal/L&T/Abb.
Supply & Fixing Power Supply Board box made out of Polycarbonate reinforced with glass fiber , Asta , CPRI Aproved OEM. The Enclosure shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Power Supply Box shall be rated for Degree of ingress Protection IP 66/67 in accordance with IEC 60529. weatherproof UV-resistant, rainwater-proof, temperature-resistant. The gasket material of enclouser shall be Polyurethane and the gasket shall be internally embedded. The Power Supply Board Box shall be complied with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5 and certificates for the same shall be submitted. The manufacturer of Enclosure shall submit a copy of IEC Certificate and the Enclouser as per approved make in MES List. For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It shall be tested at Glow Wire test for 960 degree Centigrade .The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08. The Power Supply Board shall be provided with 1No Suhcko Plug/Sockets 16/20Amp 3 Pin, 1 Nos MCB SP 16 Amp 10 KA with Flap Cover for out door protection and complete with all internal connections . The Enclosure shall be supplied with nut bolts as required, complete all as per manufacturer’s instructions, complete all as specified and directed. Make : Hensel/Siemens/GE Power/Rittal. Manufacturer should submit above test certificate of CJB/PJB
Supply and fixing MCBs Distribution board sheet metal enclosures, SPN 240 Volts, 04 ways with 200 amps rated bus bar, double door, with IP 43 protection, complete all as specified and directed.
Supply and fixing 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) single pole and current carrying capacity 5 to 32 Amp, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed.
Material and labour for Sub Main Wiring (in replacement) with two single core 10 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 10 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 10 Sqmm main cable + one run of 10 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver with three core flexible copper conductor, with cases of suitable size, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including GI earth wire on batten or in PVC conduit or in MS Conduit including fixtures and fittings such as switches, ceiling roses, pendants, fan regulators, sockets etc, removing materials to store for keeping in safe custody for reuse or for credit (credit for above items shall be made as per conditions separately) and making good disturbed surface of walls, floors, etc., complete all as specified and directed.
Material and labour for point wiring with single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including including modular cover plate and boxes for housing switches, fan regulators etc, including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100 volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii). Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 2.11 here-in-before but for 3 pin socket outlet 5 Amps on independent board.
All as per item No 2.11 here-in-before but for 3 pin socket outlet 5 Amps on same board.
Material and labour for point wiring complete with two single core multi stranded Copper conductor of size 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed 1100 volt grade colour code cable, drawn in and including non metalic rigid PVC conduit medium grade of suitable size including standard fittings such as Tee junction, bends etc, conduit concealed in wall & fixed on ceiling including modular cover plate and boxes for housing switches, sockets etc, including one 2.5 Sqmm size (nominal area) multi stranded copper conductor FRLS PVC insulated unsheathed colour code cable for earth continuity, for one multi purpose socket outlet 6 pin, 15 Amps & 5 Amps on independent board, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii) Switches etc. shall be measured and paid separately. Circuit wiring from distribution board to switch board shall be deemed included in the quoted rate of point wiring.
Supply and fixing switch modular type, single pole, one module, 5 Amps, 230 volts, complete all as specified and directed.
Supply and fixing socket outlet, modular type, multi purpose, 2/3 pin, 5 Amps, two module, 230 volts, complete all as specified and directed.
Supply and fixing socket outlet, modular type, multi purpose, 2/3 pin, 15 Amps, two module, 230volts, complete all as specified and directed.
Supply and fixing modular type fan regulator, step type (4/5 steps),120 W, two module, suitable for 1200/1400 mm sweep ceiling fans including necessary connections, complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
External Electrification Work
Supply, laying, jointing, testing and commissioning Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 300 Sqmm 3.5 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned thickness of 18 cm (overall) shall be measured for payment purpose.
Supply and laying well burnt sub class 'B' bricks for cable protection laid flat ,length wise, perpendicular to the axis of cable, complete all as specified.
Supply and laying / fixing , GI pipe light grade 100 mm dia for cable protection fixed to pole/wall or laid under floor/ road/ pavement, including MS clamp/nuts & bolts etc complete all as specified and directed.
Material and labour for boring holes under road / Pavement / hard standing by trenches technology for inserting 100 mm bore HDPE pipe, including provision of 100 mm bore HDPE pipe, complete all all as specified and directed.
Material and labour for providing earthing of advance chemical earthing system of Copper pipe Chemrode 3 mtrs long 50mm dia filled with highly conducting metallic compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip/wire to the load. To ensure the moisture content and electrical conductivity, each earthing pit shall be provided with minimum 02 bags of 20 kgs chemical compound. An arrangement for connection of copper strip (25x3mm) to rod to be made with given Terminal point with SS Nut Bolts, provision of polymer chamber with cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil complete all as specified and as directed Make : JK CHEM RODE / LPI /Alltec/True Power
Note(s) :- The qouted rates shall deem to include the following:- (i) Pit cover chamber of polymer chamber with cover, including necessary excavation in any type of soil. (ii) Copper strip with necessary brazing and GI protection pipe upto a length of 7.5m (iii) Earth resistance shall be less than 1Ohm. In case the test results are not found below 1Ohm, complete earthing will be redone without any extra cost to Govt. (iv) For effective visibility identification and traceability of earth pit (EP) with corresponding earth of eqpt and bldg, markers in metal (Mild Steel) shall be provided. Earth test of earth pit shall be provided with a colour code. The direction regarding the size, shape and colour of the Mild steel identification board etc., shall be given by the Engineer-in-Charge. (v) All joints of strip are to be brazed on both sides (over lapping) except test point.
Material and labour for earth continuity conductor or main earthing lead 20 mmx 3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
Refrigeration And Air Conditioning Work
Supply installation, testing and commissioning, High wall split type AC unit of capacity 2 TR, with cooling and heating function, with copper piping and condenser, dual inverter, with minimum 5 star rating, electric driven, single phase, indoor and outdoor unit, with cordless remote control and with in-built air ionizer and plasma filter for better indoor air quality, necessary suction and discharge copper pipelines from inner units duly insulated, including welding/ brazing to make leak proof, 15 mm bore PVC pipe of superior quality for drainage of condensed water, including cutting chases for refrigeration piping, connection cable, drain pipe etc in brick wall, necessory brackets/suitable stand for mounting outdoor /indooor units as per manufacturer's instructions and providing electrical connections and electric cable from inner to outer unit complete all as specified and directed. Make- ONIDA (S243FLT-N) or equivalant in Hitachi, Voltas, Blue star, Carrier Daikin.
Supply, installation and testing automatic voltage stabilizer of capacity 5 KVA, single phase, 230 Volts, naturally air cooled, indoor type, designed for input variation between 170 Volts to 250 Volts, having copper winding, with output voltage stabilized at 230 Volts with accuracy +-2.5%, complete all as specified and directed
Supply and fixing sheet metal enclosure, SPN, with a two pin socket and earth plug, with one MCB single pole, 240 Volts, 20 Amps, complete all as specified and directed.
Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.
Fire Alarm System Work
Supply and fixing Fire alarm control panel complying with BSEN 54, double loop panel of capacity 99 detectors & 99 modules & upto 200 detectors and module (per each loop), complete all as specified and directed
Supply and fixing Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination with self built intelligence as per IS: 11360, complete all as specified and directed
Supply and fixing addressable manual call point resetable type, complete all as specified and directed
Supply and fixing addressable electronic sounder cum strobe, complete all as specified and directed
Supply and fixing DC Power Supply 24 Volts 10 Amp, complete all as specified and directed
Supply and fixing Supply of Battery 7.2 mah, 12 Volts, complete all as specified and directed
Supply and fixing SITC of armoured cable 2 core 1.5 sqmm laying on surface along wirh required accessories, complete all as specified and directed .
Supply and fixing SITC of armoured cable 4 core 1.5 sqmm laying on surface along wirh required accessories, complete all as specified and directed .
Supply and fixing SITC of PVC conduit pipe 25 mm heavy duty pipe, complete all as specified and directed
Supply and fixing Addressable control module, complete all as specified and directed
Supply and fixing 6 Watt ceiling Speaker, complete all as specified and directed
Supply and fixing 250 Watt Amplifier, complete all as specified and directed
Supply and fixing Fire Alarm sounders / Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5 metres with sound output Variation of + 5 db 1500 metres range, complete all as specified and directed.
COMMON ITEMS FOR BUILDING WORK AND EXTERNAL ELECTRIFICATION WORK
Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth; for foundations, laying of cables etc or for cesspits, manholes,not exceeding 10 Sqm on plan, trimming and getting out complete, all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each as in soft/loose soil, complete all as specified.
Removal of surplus soil to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point including spreading levelling in layers not exceeding 25 cm thick, complete all as specified and directed.
Note: The Total amount shall be subject to adjustment of credit of Rs. 12966.75.00 for old Materials as per Schedule of Credit
ELECTRA ENGINEERS
R D Bansal
J.K & Company
MASTER CONSTRUCTION CO
R K ENTERPRISES
M/s Sahib and Company
AAR KAY BEE ENTERPRISES
NEW GURBINDER INDUSTRIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .