Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC NETAJI ROAD NICHUPATTY BOLPUR BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC Work Completed | |
| 2 | L2₹5.0 L+₹1,805 (0.36%)Rejected-Finance BOLPUR NICHUPATTY BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹5.0 L+₹5,956 (1.20%)Rejected-Finance 25 RAJKUMAR CHATTERJEE STREET KOLKATA 700057 | KOLKATA | KOLKATA | WEST BENGAL | 700057 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹5.1 L+₹11,968 (2.42%)Rejected-Finance KALIKAPUR BOLPUR BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | L4 | Rejected-Finance BEING L4 BIDDER |
Tender Value
Refer Docs
EMD Value
₹9,941
Closing Date
5 Jan 2024, 12:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
Ofc of The EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri, Dist Birbhum, Pin 731101.
Renovation of Electrical Installation, Light Fittings etc. fo Female ward and Female Cell Block of Bolpur Subsidiary Correctional Home.
2023_WBPWD_628768_1
BIRED/54/e-NIQ (1st call) of 2023-2024
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
BOLPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,941
OFC OF THE E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
22 Nov 2024
21 Dec 2023
8 Jan 2024
21 Dec 2023
5 Jan 2024
26 Dec 2023
26 Dec 2023
Amount
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ( Make : Finolex/Polycab,/ KEI/ Havells) partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall] to light / Fan / Call bell point as per GS withfollowing average run 9 Mtr.
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire ( Make : Finolex/Polycab,/ KEI/ Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS, On Board
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 2 nos 6A, plug socket with separate 2 nos 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. 6 Way ( Make - Legrand)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. i) 2+10 way [ Legrand ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] i) 40 A DP
ii) 63 A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] i) 6-32 A SP
ii) 40 A DP
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way.
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / havells / Fort Gloster/KEI] i) 2 Core 10 Sq mm
ii) 4 Core 25 Sq mm
iii) 4 Core 35 Sq. mm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of cable upto 35 sqmm through floor/pavment/wall as per GS for the following numbers of Cables.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.(TATA-M/Bansal/Jindal) i) 50 mm dia
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. i) 2 Core 10 Sq mm
ii) 4 Core 25 Sq mm
iii) 4 Core 35 sq. mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. i) 2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug)
ii) 2x (6 sqmm) + 1x (4 sqmm) (For TPNDB to SPNDB)
iii) 3 X 1.5 Sqmm
Cutting Channel of size (31 mm x 31 mm)/(40 mm x 40 mm)/(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS. i) 19 mm dia 3 mm thick
ii) 25 mm dia 3 mm thick
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works i) 100 mm x 100 mm x 65 mm
ii) 150 mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required i) 100 mm x 100 mm x 65 mm
ii) 150 mm x 100 mm x 65 mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 1.5 sqmm
ii) 2.5sqmm
iii) 4 sqmm
iv) 6 sqmm
Fixing only single/twin fluorescent light/2 ft light/surface type round light fitting/ small type Street light complete with all accessories directly on wall /ceiling by screws as per GS
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one endand thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Fixing only single/twin fluorescent/ Street light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp as per GS
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
Fixing only 90 Watt LED street light on existing arm bracket by ladder compleat with all accessories
Removing of luminaries with lamps from the pole/column and keeping them ready for despatch as per direction of EIC.
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
Supply of 4ft LED T-8 Industrial box type single batten with end cap complete with all accessories [CROMPTON (IGP161LT8-16) /Havells/Philips].
Supply of 20W LED Polycarbonet bodyT-8 lamp with in built driver with metal heat sink [CROMPTON (LT8-8-565-2) /Havells/Philips] on fittings.
Supply of 40 Watt,240 volt, street light with thermal management IP66/IP65 protection robust die cast housing with toughened glass with all accessories.(Make-Crompton (Model No-LSTS-40-CDL) or Philips or Havells)
Supply of 240 volt, 90 watt street light made up pf pressure die cast aluminium housing with toughened glass and high power LED with option of secondary optics, Efficacy-110 Lm/W with all accessories. (Make Crompton-(Model No- LSTP-90-CDL-M) or Philips or Havells)
Supply of 240 volt, 180 watt flood light made up pf pressure die cast aluminium housing with toughened glass and high power LED with option of secondary lens, Efficacy-110 Lm/W min 10 KV SPD included with all accessories. (Make Crompton-(Model No- LFLN-180-CDL/60-M) or Philips or Havells)
Supply of 240 Volt,10 watt high energy savings bulkhead light fittings.(make-Crompton (Model no- LBHP-10-CDL) or Philips or Havells)
Supply and Fixing of angular batten holder as per GS.( Make-Anchor/Pritam)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [New-3 Nos, Existing-5 Nos]
Fixing only 9" exhaust fan after making holes in wall as per GS
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) i) For GI 230 mm (9")
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) i) 1400 mm Sweep ( Aura Metallic/ USHA/Crompton )
Supply of 9"( 230 mm ) Speed 920 RPM Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC / Crompton)
S & F of digital Timer for exhaust fan with 2 pole enclosure.(Make-L&T)
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. (Upto 9.0 mtr. long pole). (i) 1st coat of aluminium paint over 1 coat of RO priming
(ii) 2nd coat of aluminium paint over 1st coat
Supplying & fixing 40 mm dia x 1.2 metre long (incl. L type bends) GI pipe vertical type service bracket on wall for carrying 3 wires and an earth wire complete with Galv. MS clamps for fixing on wall with necessary screw incl. painting, as per direction of EIC
Supply and fixing of (250 X 200X 105)mm polycarbonet loop box(Make- Sintex) fixed on existing pole by 2 nos GI Band and Screw,nut and bolts, which contais 16 Amp SP MCB,1 nos 4 way terminal making all connection complete with proper locking arrangemant by keys and mending good the damages.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required i) 40 mm dia.
S & F GI water proofing type looping cable box size 250 X 200X 100 mm deep having 4 mm thick comprising of one 250 volt,15 Amp kit-kat fuse unit, One NL on porcelain insulator, one compression type brass cable gland for upto 3 core 1.5 Sq mm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc, earthing terminal with lug, on steel tubular pole near base, including supply and fixing 40 X 6mm thick, MS clamps with bolts, nuts etc, including painting with anti corrosive paint.
MOON LIGHT
NIRMAN ENTERPRISE
PAL ELECTRICAL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .