Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹89,080Accepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹1.0 L+₹13,050 (14.6%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹1.5 L+₹57,330 (64.4%)Rejected-Finance | L-3 | Rejected-Finance L-3 |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
31 Jul 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE
400KV S/S Sarnath Varanasi
Shifting of ETD-Ghazipur office from Talwal, hydel colony, 220KV Ghazipur to new allotted ETD Ghazipur Office (Old T AND C Division Office Ghazipur) under ETD-Ghazipur
2023_UPTCL_822105_1
E-Tender No. 18 ETC-II(VNS)/2023-24
Open Tender
Electrical Works
Lump-sum
60 days
Ghazipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD Ghazipur
₹2,000
15 Sept 2023
19 Jul 2023
1 Aug 2023
19 Jul 2023
31 Jul 2023
19 Jul 2023
Amount
Shifting of ETD-Ghazipur office material from Talwal Hydel colony ,220KV S/S Ghazipur to New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) approx distance 1.5 Km. The work includes proper packing of material, loading at Talwal Hydel colony ,220KV S/S Ghazipur office then carriage and unloading at New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) office including arrangement of private vehicle, labour, T&P and other required material for packing. The detail of material is as below. (i) Wooden table of various size-10Nos, (ii) Wooden / Steel chair of various size-12 Nos, (iii) Steel rack open type of various size-03 Nos, (iv) Steel almirah of various size-11 Nos, (v) Air cooler (fiber) -01 Nos, (VI) Air cooler (Steel) -01 Nos.
Shifting of 3No. steel Almerah & record files from 132KV S/S Ghazipur Andhau to New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) approx distance 12 Km. The work includes proper packing of material at 132KV S/S Ghazipur Andhau office then carriage and unloading at New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) office including arrangement of private vehicle, labour, T&P and other required material for packing.
Shifting of ETD-Ghazipur office Desktop computer set with complete accessories from Talwal Hydel colony ,220KV S/S Ghazipur to New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) approx distance 1.5 Km. The work includes proper packing of Computer with its complete accessories, loading at Talwal Hydel colony ,220KV S/S Ghazipur office then carriage , unloading & stacking at New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) office including arrangement of private vehicle, labour, T&P and other required material for packing.
Shifting of complete ETD-Ghazipur office records files/folders from Talwal Hydel colony ,220KV S/S Ghazipur to New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) approx distance 1.5 Km. The work includes proper packing of records, files/ folders, loading at Talwal Hydel colony ,220KV S/S Ghazipur office then carriage , unloading & stacking at New alloted ETD Ghazipur office (Old T&C Division office Ghazipur) office including arrangement of private vehicle, labour, T&P and other required material for packing.
Removing of deffective & damaged electrical wiring and installation by new wiring at its place for lighting system on fall cealling & side wall of ETD-Ghazipur building with 1.0 Sq. mm. FR PVC insulated multi strand single core copper cunductor cable for light point and 1.5 Sq. mm. FR PVC insulated multi strand copper conductor cable as earth wire drawn inside the conduit with piano type switch, ceiling rose & holder on 3 mm thick phenolic laminated backelite sheet ETD.including the cost material, labour and T&P charges ETD. required for proper completion of work as per direction and satisfaction of engineer in charge.
Removing of deffective & damaged electrical wiring and installation by new wiring at its place for Fan/exhaust fan of new alloted ETD-Ghazipur building with 1.5 Sq. mm. FR PVC insulated multi strand single core copper cunductor cable for Fan point and 1.5 Sq. mm. FR PVC insulated multi strand copper conductor cable as earth wire drawn inside the conduit with piano type switch, ceiling rose on 3 mm thick phenolic laminated backelite sheet ETD.including the cost material, labour and T&P charges ETD. required for proper completion of work as per direction and satisfaction of engineer in charge.
Removing of deffective & damaged electrical wiring and installation by new wiring at its place for Plug point of new alloted ETD-Ghazipur office building with 1.5 Sq. mm. FR PVC insulated multi strand single core copper cunductor cable for light point and 1.5 Sq. mm. FR PVC insulated multi strand copper conductor cable as earth wire drawn inside the conduit with 01 No piano type switch and 5 pin socket 6A/250V flush type universal socket on 3 mm thick phenolic laminated backelite sheet ETD.including the cost material, labour and T&P charges ETD. required for proper completion of work as per direction and satisfaction of engineer in charge.
Removing of deffective & damaged electrical wiring and installation by new wiring at its place for Power Plug point of new alloted ETD-Ghazipur building with 1.5 Sq. mm. FR PVC insulated multi strand single core copper cunductor cable for Power point and 1.5 Sq. mm. FR PVC insulated multi strand copper conductor cable as earth wire drawn inside the conduit with 01 No piano type switch and 5 pin socket 15A/250V flush type universal socket on 3 mm thick phenolic laminated backelite sheet ETD.including the cost material, labour and T&P charges ETD. required for proper completion of work as per direction and satisfaction of engineer in charge.
Removing of deffective & damaged electrical wiring and installation by new wiring at its place for Call bell of new alloted ETD-Ghazipur office building with 1.0 Sq. mm. FR PVC insulated multi strand single core copper cunductor cable drawn inside the conduit with 01 No piano type bell push switch.including the cost material, labour and T&P charges ETD. required for proper completion of work as per direction and satisfaction of engineer in charge.
Supply & fixing of 32 Amp. MCB (10 KA)
Supply & fixing of 20 watt tube light with complet set
Supply & fixing of 9 watt CFL
Supply and fixing of CFL gate light Pamma door on gate of new alloted ETD-Ghazipur office building including all cost of materials required for fixing the same. Laying and termination of 2x2.5 mm square. Control cable is required from control room to main gate of switchyard. Control cable will be provided by the department free of cost.
Providing & fixing of Division Name plate board of size 5Feet x4feet made of iron sheeet along with stand of height 1.5 metre of iron angle. The work includes cutting of iron sheet & iron angle & then welding 7 other associated work to complete job satisfactorily.Iron sheet will be provided by contractor & iron angle for stand will be provided by department free of cost.
Cleaning and removing of old, dusted wall surface of office building with the help wire brush then one coat painting on wall surface with weather proof paint of APEX brand .including the cost material, labour and T&P charges ETD. required for proper completion of work as per direction and satisfaction of engineer in charge.
M/S SANDEEP TRADERS
M/S PRABHATT ENGINEERING WORKS
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .