Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC 16 18 2ND SURTI CHEMBER DHOBI TALAO LANE MUMBAI MUMBAI MAHARASHTRA 400002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹39.7 L+₹8.4 L (26.8%)Rejected-AOC | L2 | Rejected-AOC Being other than Lowest Tenderer | |
| 3 | L3₹43.4 L+₹12.1 L (38.6%)Rejected-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L3 | Rejected-AOC Being other than Lowest Tenderer | |
| 4 | L4₹48.7 L+₹17.4 L (55.6%)Rejected-AOC B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L4 | Rejected-AOC Being other than Lowest Tenderer | |
| 5 | L5₹49.0 L+₹17.7 L (56.6%)Rejected-AOC | L5 | Rejected-AOC Being other than Lowest Tenderer |
Tender Value
₹44.7 L
EMD Value
₹90,000
Closing Date
18 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8464 REPAIR MAINT TO ELECTRIC SUPPLY NETWORK COMPONENTS INCLUDING CABLE DUCT AND CABLE TRAYS AT VARIOUS JETTY AT ND MBI
2022_MES_539859_1
8464/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender document
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹90,000
Yes
31 Oct 2022
21 Jul 2022
20 Aug 2022
28 Jul 2022
18 Aug 2022
4 Aug 2022
21 Jul 2022 - 28 Jul 2022
Amount
Supply and fixing in repair Framed work such as grills,gratings, etc.. with ends of bar shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walkways; railings; framework of water tanks, cable trays and similar work conforming to Fe.290.Gde-E-165
S & F in repair, Mild steel, plain, blacksheet in wall cladding,steel gates and similar work, cut to size, holes punched; including ground headed screws,clout nails or rivetsand fixed to wood orsteel framing withplain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required but of thickness not less than 1.00mm all as specified and directed .
S&F in repair of MS/ GI hot dip/ powder coated perforated GI cable tray sheet thickness not less than 1.6mm ,50 mm height of tray and width not less than 450mm to be fixed on any wall (brick/stone) vertically/horizontally ,including tray cover of thickness not less than 2.00mm,including all accessories complete bending, shaping, drilling, welding, cutting and including all fixing arrangement such as suitable size of nuts, bolts, coupler plates etc complete all as specified and directed by Engr-in-charge.
S&F in repair of GI hot dip/ powder coated GI cable ladder sheet thickness not less than 1.6mm ,75 mm height of tray and width not less than 500mm to be fixed on any wall (brick/stone) vertically/horizontally ,including tray cover of thickness not less than 2.00mm,including all accessories complete bending, shaping, drilling, welding, cutting and including all fixing arrangement such as suitable size of nuts, bolts, coupler plates etc complete all as specified and directed by Engr-in-charge.
S&F in repair of GI hot dip/ powder coated GI cable ladder sheet thickness not less than 2.0 mm ,75 mm height of tray and width not less than 1000mm to be fixed on any wall (brick/stone) vertically/horizontally ,including tray cover of thickness not less than 2.00mm,including all accessories complete bending, shaping, drilling, welding, cutting and including all fixing arrangement such as suitable size of nuts, bolts, coupler plates etc complete all as specified and directed by Engr-in-charge.
S & F in repair MS plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk) forming holes, without any attachment and similar work conforming to Fe 410-W(Gde-E- 250) quality A all as directed and specified.
Taking down and refixing exisitng LT Cable aluminium/copper any size laid on wall/floor , including all accessories all as directed and specified
Supply and fixing in replacement of galvanised pipe light grade 100 mm dia for passing of cables under the road cutting
Supply and fixing in replacement of galvanised pipe light grade 80 mm dia for passing of cables under the road cutting
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded ALUMINIUM conductor of size 95 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza/ Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded ALUMINIUM conductor of size 185 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza/ Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded ALUMINIUM conductor of size 240 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza/ Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded ALUMINIUM conductor of size 400 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 1.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete for One light/fan/bell point controlled by one 5A switch complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
One light point controlled by one 5A switch
One fan point controlled by one 5A switch
One Bell point controlled by one bell push
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring (Work station for computer)complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete necessary electric connection for each workstation point comprising of 03 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/ Plaza
S & F in replacement of Bell push, 5/6 Amps, 240 volts SP complete all as directed.
S & F modular switch 1 way 6A all as specified and directed by EIC.
S & F modular switch 1 way 16A all as specified and directed by EIC.
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC.
S & F modular socket, 16A - 2/3 pin combined 2 modules all as specified and directed by EIC.
S & F in replacement of fan regulator electronic step type socket size and making all necessary connections complete all as directed.
S & F in replacement of bell, DINGDONG type, 6 Amps, 240 volts, SP complete all as directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 teRunning Metreinal, 240 volts, 5 Amps complete all as directed.
S & F in replacement of lamp holder PVC/polycarbonate insulated body type complete all as directed.
S & F in repair 4 feet, 20W LED tube rod having high quality cross linking glass material T8 retrofit type all as specified directed. Make -C&S cat part No-LT4F20WLEDT8/WDI (TARA-i SERIES) or equivalent Cat part in Bajaj / Philips
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .