Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.3 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹54.2 L+₹3.9 L (7.72%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC REJECTED | |
| 3 | Rejected-Technical | - | Rejected-Technical No Remark in WLR | |
| 4 | Rejected-Technical | - | Rejected-Technical TENDER FEE NOT RECEIVED |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
4 Feb 2022, 6:00 pmClosed
GE NW BHANDUP
GE(NW) BAHDNUP, MUMBAI
Repairs/ Replacement of Street Lights and LT cable at Ghatkopar firefighting , DG set Water supply at NAE Santacruze UNDER GE(NW) BHANDUP
2022_MES_499249_1
8173E8
Open Tender
Civil Works
Item Rate
180 days
GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹99,000
4 Apr 2022
4 Jan 2022
7 Feb 2022
4 Jan 2022
4 Feb 2022
19 Jan 2022
Amount
Comprehensive maintenance of electrically operated travelling (EOT) crane of 05 MT, Span -44900 mm, SWL-5000 Kgs capacity, floor operated comprising of hoist motor, micro motor, long travel motor, cross travel motor, gear box, control panel and other connected accessories installed at NAE Santacruz Make- Dinesh Enterprises Ser No- 1215 The following spares replacement :-
M & L for painting 5 ton crane completely with two coats of golden yellow paint including preparation of existing surface by scrapping detoritied paint etc. all as directed by Engr-in-charge.
To carry out load Test of 5 MT Crane as per Manufacturer norms and provide a load test certificate by manufacturer all as specified.
Repair, Maintenance & Servicing of DG Set 500 KVA Make- Crompton Greaves Model No 12V14TAG complete including with B Check through OEM as per direction of Manufacturer as directed. Spares replacement of the following :-
Supply and replacement of Greaves Max Therm Lub Oil
Supply and replacement of Oil filter
Supply and replacement of Fuel filter
Supply and replacement of K Kool additive oil
Comprehensive /Annual maintenance of CCTV System installed at NAE Santacruz and comprising of the following items as under :- Mini PTZ Dome cameras-4 Nos 16 Ch digital video recorder (DVR) - 01 No KBD digital keyboard/Joystick 24 Volt 2.1 Amp power supply -03 Nos Professiona CCTV Bosch monitor 21.5"-01 No Panasonic 22" LED TV -01 Nos 2 TB Survelliance harddisk Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
Comprehensive Annual maintenance of fire alarm system installed at NAE Santacruz comprising of following items Main control panel -02 Nos Heat and smoke detector-150 Nos Mannual call point -12 Nos Hooter cum strobe- 20 Nos Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
Supply and fix in repair Smoke and Heat Multisensor detector complete all as specified and directed. Make- Apollo XP95 Model 55000-885
Repair and maintenance of 75 HP fire service main pump multi stage having 2280 LPM at 80 Mtr head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100 HP diesel engine including servicing by replacing unserviceable items of gland packing , bearing and charging lubricants for smooth running including servicing of 75 HP diesel engine by replacing filters, lubricant oil including defective parts like coupling , oil air filters, servicing of radiator, replacement exhaust gasket, replacement of diesel supply and return pipes from tank to engine, battery leads and checking of charging circuit complete including base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed.
Takig down unserviceable Fire fighting motor pump set of capacity 3 phase 100 HP disconnecting the all necessary electrical connections and dismantlng the pump side and replacing the worn out winding and connected items like bearings, bush and coupling and rubber coupling etc; and rewinding with super enameled copper wire of suitable guage including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete all as specified.
Repair and maintenance of 7.5 hp fire service jockey / booster pump multi stage having 180 LPM at 56 mtrs head multi stage pump of horizontal split casing running at 2900 RPM coupled with 7.5 hp AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed.
Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 02 ton of any make /type after disconnecting refrigerant pipes , drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda , checking and replacing the spares like relay, capacitors, thermostat, fan motor blades & blower and including servicing, overhauling and connecting of refrigerant pipe, drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed.
Repair/Replacement of fire fighting hose reel of 20mm dia & 30 mtrs long confirming to IS-5132 complete all as specified and directed
Repair/Replacement of fire fighting branch pipe & nozzle for 20 mm dia hose reel confirming to IS 8090 complete all as specified and directed
Repair/Replacement of fire fighting fire hydrant stand post with provn of single outlet confirming to IS 908 complete all as specified and directed
Repair /Replacement of fire fighting branch pipe & nozzle gun metal short branch pipes 63mm dia with male instantaneous inlet with Gun metal, hexagonal, detachable outlets nozzles bearing IS-903 complete all as specified and directed
Repair /Repalcement of Hydrant valves Female oblique type gun metal hydrant valve bearing IS 5290 type A 63 mm dia with flanged inlet and female instantaneous spring back outlet connection and complete with male blank cap & chain single hydrant valve
Supply and fixing blower drum for split type air conditioner 2.0 ton capacity complete all as specified
Supply and fixing outdoor fan blade for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fixing outdoor fan motor for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fixing running capacitor 45 mfd for split type air conditioner 2.0 ton capacity complete all as specified
Supply and fixing starting capacitor 100 mfd for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fixing fan capacitor 4 mfd for outdoor unit for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fix new hermetically sealed compressor in existing split type air conditioner 2.0 ton capacity including initial filling of refrigerant gas to the required pressure , brazing making electric/piping connection etc complete all as specified and directed Make – Voltas / Shriram / Tecumesh /Kirloskar / Hitachi/LG / Bluestar
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
M&L for river washed sand and screened dry for caushioning to ug cables in trenches below and around under ground cable for coushioning of cable in ducts including spreading and levelling complete.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 10 Sqmm, 3 core complete all as specified.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 25 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 35 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 120 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 150 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 240 Sqmm, 3.5 core complete all as specified.
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and laying HDPE pipes of pressure rating 6 kgf/cm2 (PE-63 grade) of size 32 mm bore laid in trenches for passing of cable complete all as specified and directed.
Supply and laying HDPE pipes of pressure rating 6 kgf/cm2 (PE-63 grade) of size 40 mm bore laid in trenches for passing of cable complete all as specified and directed.
Material and labour for GI tubes "Medium Grade" 50 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection complete all as specified and directed.
Material and labour for GI tubes "Medium Grade" 80 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection complete all as specified and directed.
Supply and fixing in repairs LED bollards light fitting 10 to 15 watt mushroom shaped made in cast aluminium spigot housing with decorative clear acrylic diffuser for pleasant light output and weather proof and IP65 protection complete all as specified and directed. Make :Shakti Model No. SZPGMMX010
Supply and fixing in repairs LED post top lanterns fitting made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection 12/15 watt complete all as specified and directed. Make :Philips/Luckar/CG/Havells
Supply and fixing in repairs highly efficient high power multi LED flood fitting 100/120 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Philips/Luckar/CG
Supply and fix in repairs highly efficient high power LED street light fitting 100/120 W with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP65 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting. Make:Philips/Luckar/CG
Supply and fix in repairs highly efficient high power 45/50 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting. Make: CG/Luker/Havells/Shakti
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall complete all as specified and directed. Note : Clamps nuts bolts etc will be measured and paid seprately under relevant items.
Supply and fixing in replacement pole mounting box FRP type of size 250mm x 175mm x 100 mm, 3 phase with locking arrangements including necessary nut, bolt and clamps of the flat iron of size 25mm x 4 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'C' series and 3 phase connector 100Amp for incoming/outgoing cables with proper fixing arrangements on pole / wall complete all as specified and directed. Make: National/ Sintex
Supply and fixing in replacement pole mounting box FRP type of size 140mm x 140mm x 100 mm, 3 phase with locking arrangements including necessary nut, bolt and clamps of the flat iron of size 20mm x 3 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'C' series and 3 phase connector 100Amp for incoming/outgoing cables with proper fixing arrangements on pole / wall complete all as specified and directed. Make: National/ Sintex
M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (03 Run of 2.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified.
Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, "J" type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a) MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b) 4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes: (a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) .quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling. Make : BAJAJ Model BOP-7030 or its equivalent in Crompton/Philips / Wipro as approved by the GE.
M&L for mild steel TMT bars 6 mm to 8mm dia cut to length, bent to shape required, stirrups, spaces and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed
M&L for RCC type B-1, 1:2:4 (nominal mix) using 20 mm graded stone aggregate as in footing, columns, post, pillars, piers, wall of culverts, suspended slabs, edges and struts etc complete all as specified and directed
M&L for farm work to sides of concrete footings, columns, posts, pillars, piers, edges and struts of rectangular or triangular shape for rough finished flat concretesurface complete all as specified and directed
Supply & fix of Street light control console made out of 2mm thick MH Sheet and paineted with powder coated paint suitable for and including the following items prewired complete, dimantling of existing unserviceable MCCB/MCB and reconnecting the UG cables in new control console by replacing cable glands and lugs all as specified and directed. a. Programmable electronic timer with one change over of capacity 16 Amps- 1 No b. Three pole contactor 70 Amps, 415 Volt - 1 No c. Surface mounted 16 Amps modular type 2 Way switch with box complete - 1 No d. MCCB 4 pole 100 Amps with breaking capacity 25 KA adjustable type with extended terminals - 1 No
Supply and fixing in repairs high bay LED light fittings with highly efficient LED baylight made of pressure die cast aluminium housing extraded aluminium heat sink & enclosed with toughended glass IP 66 of capacity 100W , power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on truss with MS Clamps made out of 25x5mm flat iron with nuts, bolts etc complete painting with two coats synthetic enamel paint over a coat of red oxide complete dismantling existing unserviceable high bay fittings all as specified and directed. Make Philips/CG/Luckar
M & L prepration of old exposed surface of garden light pole 1.5/ 2.5/5 meter long applying two coats of aluminium paint over a coat of anticorrosive paint including painting to bottom of pole complete all as specified and directed.
Servicing of complete solar battery 100AH 12V including cleaning the terminals and replacing unserviceable brass battery clamps and toping up of distilled water including cleaning of solar pannels on 5 mtr height pole/roof top - 29 Nos solar light fittings/pole complete all as specified and directed.
Manning & operation for electric supply installations 11/0.433 KV sub Station & stand by diesel Generator Sets comprising of transformer, AMF panels, APFC panels, HT VCBs, ACBs, LT Panels/FP Boxes, LT/HT UG Cables, lightning Arrestor, Earthing,metering equipments & batteries etc including routine maintenance, cleaning of equipments, Maintaining of daily records of electric supply and log books of DG sets with all parameters with stationery and including atending of electrical break downs and electrical repairs as directed with necessary expendable items and providing all types of tools and clamp meter, IR/ER tester, Earth rod, Hand Gloves, ladders etc and adopting necessary safety precautions in attending break downs, and electrical repairs, switching on/off street lights, top up of fuel as provided/stored by department and cleaning of equipments and surrounding area of installations in neat and presentable position by deploying Electrician (ITI Holder) - 01 in each shift of 08 hours duration required in two shifts in a day in all the days including sundays and holidays with arrangement of reliever duty at NAE Santacruz comprising of following shifts complete all as specified and directed :- Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs NOTE : Arrangement for deposition of necessary documents for issue of passes from MIAL/CISF/GVK authority for the trademen will be contractor's responsibility in consultation with MES/ users.
Outsourcing of services for watersupply and fir fighting installations with pump sets 03 phase, 415 Volts, AC 50Hz comprising of pumping panel boards, control cables, metering equipment, earthings, star delta/DOL starters, etc including operating of valves, NRVs and connected pipe lines and routine maintenance, maintaining of dailyrecords of pumping installations with all parameters with stationery and including attending of water supply break downs as directed with necessary expendable items and providing of tools and clap meter IR/ER tester etc and adopting necessary safety precautions in attending break downs and cleaning of equipment and surrounding area of installations in neat and presentable position by deploying Fitter General Mechanic(FGM) ITI Holder - 01 No in each shift of 08 hours duration required in three shifts in a day round the clock(24 Hours ) in all the days including Sundays and Holidays with arrangement of reliever duty with following equipments/installations at NAE Santacruz comprising of following shifts complete all as specified and directed (a) Centrifugal pump set of make Kirloskar 05HP - 02 Nos (b) Fire fighting pump (AC driven) 2850 LPM (c) fire fighting pump ( diesel engine driven) 2280 LPM (d) Jockey pump 180 LPM (e) Fire Fighting piping network with hydrants and valves. Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs Note : Arrangement for deposition of necessary documents for issue of passes from MIAL/CASF/GVK authority for the tradesmen will be contractor's responsiblity in consultation with MES/ users.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 93890.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
cooltech engineering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .