SE PURANIA, LUCKNOW
SE PURANIA, 33/11KV SUB STATION PURANIA, LUCKNOW
Installation of 11 No 250 KVA New DT at Different Places in the work area of Sub Division Purania under the jurisdiction of EUDD-Daliganj, Lucknow
2025_MVVNL_1071491_1
28/EUDC-PURANIA/2025-26
Open Tender
Electrical Works
Item Wise
365 days
EUDD DALIGANJ
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE.EDD BKT, LUCKNOW
₹43,100
20 Sept 2025
5 Sept 2025
12 Sept 2025
5 Sept 2025
12 Sept 2025
5 Sept 2025
Amount
Loading, carriage & unloading of following materials from centre store daliganj to work site and its stacking. Distance approx (0-35) kms.
250 KVA T/F
LT PVC Cable 1X400/3.5X240/1X70 SQMM
ABC (3x120/95/70/25/16) Sqmm.
ST Pole 11 Mtr long
11 KV Cable XLPE
11 KV CJ KIT O/D,I/D/ST
OTHER LINE MATERIAL
Erection, Fabrication reaction of sub-station type double pole on 8.5 mtr long PCC/11 mtr long ST pole along with fixing of necessary clamps. Accessories required including supply & fixing of straight MS 100x50mm top channel (2240 mm long) one no. dropper channel/Angle 100x50 mm 2 Nos. with arrangement of fixing 3 Nos pin insulator as per RESPO specification and direction of E/I. Only pole & insulator supplied by the dept.
Construction of T/F Plinth of size 2x2x1.2 meters with help of 1st class bricks and missionary in the ratio 1:4 cement & sand coarse, filling the structure completely as per norms with RCC top 1:2:2 cement, sand coarse, stone grit with MS bar and MS channel for resting T/F. All material shall be arranged by the contractor.
Wiremess fencing of 11/0.4 KV shall be made of rectangular of size per site requirement not exceeding 3 meter fabrication 45x45x5 mm angle the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mess. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with MS flat of size 25x3mm to supports as per RESPO specification & direction of E/I. .
Grouting and wielding of fencing, grouting will be done all surrounding of fencing and welding for proper support to fencing in between fencing there will be an extra vertical angle for proper grouting support for each corner and in middle including painting of fencing with two coat of primer and two coat of enamel paint.
Construction of Masonry type Distribution pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and MS round bar of 10 mm dia including supply and mounting of 02 nos. Straight MS angle 50x50x6x750 mm-2 nos.
Supply and fixing of Henley type tailless fuse units 500 Amps, 650 Volts one no. for incoming and other for outgoing, Copper bus bar 4 nos. 1000x50x6 mm with locking arrangement made of 18 SWG BP Sheet.
Erection & commissioning of (3x120/95/70/25/16 Sq.mm) Aerial Bunched Conductor.
Laying of LT PVC Cable 1x400/3.5x240 SQMM as RESPO specification & direction of E/I.
Earthling of T/F Pipe type with 80 fit deep boring and providing GI Pipe 1.5" dia (80 fit GI Pipe) and GI strip 50x5 mmx6 meter long attached with clamps. L piece, nut & bolts and GI pipe Cap. All material shall be supplied by the contractor.
80 feet Boring for earthling of transformer with machine or manual and after pipe fixing grouting and fixing with Cement and Morang and making chamber for proper watering in summer season all material like machinery for boring and water tanker will be supplied by contractor
Safe Installation of 250 KVA T/F on double pole by providing and fixing of all accessories along with making HT/LT connection and its commissioning.
Providing and fixing of 11 KV DO fuse set along with clamps & nut bolts on new/existing of double pole.
Providing and fixing of channel of DO FUSE SET AS PER RESPO NORMS.
Ordinary earthling by MS earth Rod 2500 mm long as per RESPO Schedule. All material like GI wire & Earth Rod shall be supplied by the Contractor.
Ordinary earthling by MS earth Rod 2500 mm long as per RESPO Schedule. Only GI wire & Earth Rod shall be supplied by the department.
Laying of cable double circuit 11 KV XLPE cable (3x35/70/120/170/185) sqmm in kaccha road by digging of trench laying cable with first class brick bixinh and sand,/HDD METHOD /DRILLING METHOD single ckt as RESPO specification & direction of E/I.
Laying of cable double circuit 11 KV XLPE cable (3x35/70/120/170/185) sqmm in pakka road by digging of trench laying cable with first class brick bixinh and sand,/HDD/DRILLING METHOD as RESPO specification & direction of E/I.
Laying of cable single circuit 11 KV XLPE cable (3x35/70/120/170/185) sqmm in pakka road by bore type method as RESPO specification & direction of E/I.
Laying of cable double circuit 11 KV XLPE cable (3x35/70/120/170/185) sqmm in pakka road by bore type method as RESPO specification & direction of E/I.
Laying of cable single circuit 11 KV XLPE cable (3x35/70/120/170/185) sqmm in air pole to pole by using proper clamp and GI wire as RESPO specification & direction of E/I.
Supply and laying OF HDPE PIPE
Supply and laying of interlocking tiles inside T/F Fencing
Grouting and plinthing bof support PCC/STP as per RESSPO Specification
Painting of pole as per RESPO Specification with two coat of primer and two coat of enamel paint.
Hosting of 11 KV Cable on pole including supply of G.I. Pipe and clamps.
Divination of Load from existing 400 kva transformer to new 250 KVA transformer
Supply & fixing
CJ KIT OD/ID 3X70/120/185 sqmm
CJ KIT ST 3X70/120/185 sqmm
AlU LUG 70/250/400/630 KVA
DANGER BOARD with clamp
BARBED WIRE
CLAMP FOR LT ABC/pole
LT CONNECTOR
COPPER L-PIECE
Number plate
Stone pad
Root marker
PRACHI ENTERPRISES (BID ID -5529118)
MEEMANSA ENTERPRISES (BID ID -5529223)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .