| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.6 LAccepted-AOC VILL PO BARKHOPA TAMULPUR PS TAMULPUR DISTT BAKSA ASSAM 781367 | BAKSA | ASSAM | 781367 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹43.8 L+₹1.4 L (3.29%)Rejected-Finance VILL BAREGAON PO CHAK CHAKA BAZAR DIST BARPE | BARPETA | ASSAM | 781301 | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹44.3 L+₹1.9 L (4.40%)Rejected-Finance P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L-4₹44.4 L+₹2.0 L (4.72%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L-4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L-5₹45.0 L+₹2.6 L (6.10%)Rejected-Finance | L-5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
10 Jul 2025, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
SPL REP TO BLDG NO ET-66 AND PROVN OF HARD STANDING WITH PAVER BLOCK AND PATHWAY WITH CHEQUERED TILES AT CERTAIN UNIT IN DARRANGA MIL STN UNDER GE RANGIA
2025_MES_715884_1
8935/RNG/E8
Open Tender
Civil Works
Item Rate
180 days
DARRANGA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹85,200
Yes
25 Jul 2025
20 Jun 2025
12 Jul 2025
20 Jun 2025
10 Jul 2025
5 Jul 2025
20 Jun 2025 - 28 Jun 2025
Amount
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge.
M&L for taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge.
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
Demolition of Reinforced Cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete including necessary formwork, complete all as per specified and as directed by Engineer-in-charge.
M&L for Providing precast cement concrete louvres and jallies, 35mm thick (measured solid), including all mouldings but excluding frame of Type B-0, 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced Cement Concrete, M-20 (Nominal Mix), 1:1½:3, type A-1 (20mm graded stone aggregate) in Beams, cantilevers, chajjas, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Formwork to sides and soffits of floor or roof beams, chajjas, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 21 here-in-above, but for erection & febrication only, complete all as per specified and as directed by Engineer-in-charge.
S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames for double shutter doors of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, and filling in frame with Cement Concrete 1:2:4, type B-0 (12.5mm graded aggregate) including necessary Formwork as required at Site(s), complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engineer-in-charge.
S&F of 30mm thick factory made second class hard wood Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and both faces are covered with decorative face veneer with lipping/frame to match; complete all as specified and as directed by Engineer-in-charge.
S&F of 30mm thick factory made second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); complete all as specified and as directed by Engineer-in-charge.
S&F of 100 mm long Butt hinges, medium weight, stainless steel, complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm long Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S&F of 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
S&F of Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with Sub-class 'B' bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L for Brickwork with Sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:6 on other than fair faces of brick work or concrete surfaces/ other side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 on fair faces Brick Walls/Concrete Surfaces/ one side of lathing, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor finish or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor/ path/ hardstanding or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing glossy finished Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Machine pressed precast concrete interlocking paver block any shape and size onfirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with grey cement and pigment, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 38mm wide glass dividing strips, 3mm thick, inserted in position, conform to design, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats with and including supplying & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based semi-corrugated (trapizoidal profile) steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 2.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl concealed (on wall only) PVC conduit (medium grade) with fittings of adequate dia and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and modular metal flush boxes of suitable size for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred), complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 56 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 56 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 56 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F Modular Switch, One Module, 1-Way, 10 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Switch, One Module, 1-Way, 20 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Socket, 2/3 Pin, combined, Two Module, 10 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Socket, 2/3 Pin, combined, Two Module, 20 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of Modular stepped type electronic fan regulator, 120W, Two module, 240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 3-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 4-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 6-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 12-module, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body with back plate, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 12 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Single Pole & Neutral (SPN), 'C' Curve, 63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, metal body, heavy duty, AC single Phase, 230V, 50 Hz, RPM 1200, Copper winding of size 380mm sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED tube light fitting (separate Batten and rod shall be measured as single unit) 1x 20W, (4 Feet) with decorative aluminium housing batten & 6500K, 220-240 Volts, AC with and including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with and including necessary mounting arrangements of bracket made out of 1.2m long 32mm dia light grade GI pipe bend to required shape with necessary fixing clamps (MS flat iron clamp 25x4mm) nut-bolts and applying two coats of aluminium paints on the MS surfaces, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including PVC conduit (medium grade) ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC conduit (medium grade) with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC conduit with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured as length of PVC conduit only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing and taking down existing old damaged cable, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & Laying Sub-class 'B' Bricks, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old damaged earthing, complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire.
M/s DEBOJIT ROY (BID ID -3354246)
MUKUL CHOUDHURY (BID ID -3353278)
M/S Rajkamal Enterprise (BID ID -3352365)
R K Enterprises (BID ID -3353900)
M/S S.S. Construction (BID ID -3351913)
M/S KIRAN ENTERPRISE (BID ID -3351945)
MR KULEN HAZARIKA (BID ID -3352874)
M/s Narzary Enterprise (BID ID -3352140)
LONDON SWARGIARY (BID ID -3352180)
M/S NARAYAN ENTERPRISE (BID ID -3352347)
KAKWANI BUILDERS (BID ID -3350873)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .