Loading…
Loading…
Tender Value
₹84.5 L
EMD Value
₹1.7 L
Closing Date
23 Dec 2025, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
17 conditions · 5 needing a document upload
Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE-I/CT/GCC- 2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
35 conditions · 5 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. tenderer shall submit GST certificate along with the offer.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
Tender involves rewiring of mainly occupied staff quarters. Therefore, availability of quarters for re-wiring will be limited in numbers and in gradual manner. Contractor cannot demand availability of all staff quarters (proportional to tendered qty) simultaneously and cannot claim any type of relaxation on this account.
The plastering work after cutting of grooves shall be finished properly in the level of original wall with painting/white wash to the satisfaction of Railways.
The contractor has to submit drawing/plan showing route diagram to consignee for signature of concerned SSEs of other departments. It required geological survey to be conducted at his own cost to avoid damage of any other cable/Pipe etc.
Contractor has to depute sufficient number of efficient manpower to carry out the work in parallel at different sites under scope of instant tender. No any excuses regarding non- availability of material and manpower for carrying out the work concurrently/parallelly at various sites shall be admissible.
Electrical work in connection with:- 1) Replacement of 20 Type-I over aged dangerous and substandard quarters with Type-II qtrs at TKD Railway colony. 2) Replacement of old condemned type-I quarters with type-II Railway quarters at Palwal station (Total 25 units) on NDLS-PWL section. 3) Construction of Ward and Cabin at EYE OPD building . 4) Renovation of Auditorium at NRCH .
16-SRDEE-G-DLI-2025-26~NR
16-SRDEE-G-DLI-2025-26
Open
Works - General
3 Months
Delhi, Delhi
₹0
₹1.7 L
23 Dec 2025
1 Dec 2025
9 Dec 2025
114 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 32,08,691 | ||
| — | 315.00 | — | — | ||
| Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required. CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.10.1 and as per explanatory note. Group A | — | — | — | 3,19,725 | |
| — | 315.00 | — | — | ||
| Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required. CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.10.2 and as per explanatory note. Group B | — | — | — | 3,72,330 | |
| — | 45.00 | — | — | ||
| Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel, conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required of reputed make complete conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.4 and as per explanatory note. | — | — | — | 89,145 | |
| — | 225.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6A modular switch, connections etc as required. as per IS, IE rule & site requirement of reputed make conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.31 and as per explanatory note. | — | — | — | 1,07,325 | |
| — | 360.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections etc as required. as per IS, IE rule & site requirement conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.32 and as per explanatory note. | — | — | — | 2,10,960 | |
| — | 180.00 | — | — | ||
| Supply, fixing, testing and commissioning of surface mounted / flush type power unit complete with suitable modular plate, 25A MCB, starter, plug & socket for A.C. & Geyser as per IS & IE rules and as per site requirement conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.57 and as per explanatory note. | — | — | — | 1,30,860 | |
| — | 45.00 | — | — | ||
| Supply, fixing, testing and commissioning of call bell/buzzer suitable for single phase 230V. make Legrand, Crabtree, Philips, Anchor or equivalent complete as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.38 and as per explanatory note. | — | — | — | 4,455 | |
| — | 75.00 | — | — | ||
| Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. of reputed make complete as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.25 and as per explanatory note. | — | — | — | 27,675 | |
| — | 180.00 | — | — | ||
| Supplying and fixing brass batten/angle holder including connection etc of reputed make complete as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part- I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.34 and as per explanatory note. | — | — | — | 23,580 | |
| — | 410.00 | — | — | ||
| Supplying and fixing 3pin,5A ceiling rose on the existing junction box/wooden block including connection etc of reputed make complete as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.33 and as per explanatory note. | — | — | — | 35,670 | |
| — | 320.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.2 and as per explanatory note. Size : 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | — | — | 88,000 | |
| — | 205.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.3 and as per explanatory note. Size : 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | — | — | 68,470 | |
| — | 160.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.4 and as per explanatory note. Size : 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 70,240 | |
| — | 11.00 | — | — | ||
| Earthing arrangement by providing earth electrode of GI pipe 40 mm dia (B-class) 4.5 Meter long with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch board to distribution board/poles etc. as per site requirement including masonry enclosure cover plate with locking arrangement & watering pipe etc. with charcoal/coke and salt as per IS, IE rules and site requirement conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 5.2 and as per explanatory note. | — | — | — | 75,405 | |
| — | 100.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No. 7.1.1. and as per explanatory note. Upto 35 sq. mm | — | — | — | 38,700 | |
| — | 115.00 | — | — | ||
| — | — | — | 75,440 | ||
| — | 45.00 | — | — | ||
| — | — | — | 1,83,330 | ||
| — | 45.00 | — | — | ||
| — | — | — | 1,12,950 | ||
| — | 45.00 | — | — | ||
| — | — | — | 1,21,050 | ||
| — | 45.00 | — | — | ||
| — | — | — | 5,65,380 | ||
| — | 1.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of outdoor type front operated double door weather proof feeder pillar (confirming to IS/IEC 61439 latest) having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to IS/IEC 60947 or latest with digital measuring instrument & bus-bar arrangement and confirming to PCEE/NR's spec. No. PCEE/NR/126-Elect/PS/2019 at Tech Spec-III attached or latest and as per IS, IE rules and site requirement and as per explanatory note. It should be rodent entry proof. It should also include well dressing and coding of circuit. a) 160A Microprocessor MCCB 4P 36 KA = 01 No. (Incoming) b) 63A Microprocessor MCCB 4P 36 KA = 05 Nos. (Outgoing) | — | — | — | 2,48,691 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .