Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC A SECTOR BHAGWATI BHAVAN VIJAY NAGAR LAL GHATI BHOPAL M P 462030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹14.7 L+₹1.3 L (9.37%)Rejected-Finance 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹15.0 L+₹1.6 L (11.6%)Rejected-Finance WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance HIGHER RATE | |
| 4 | L4₹15.4 L+₹2.0 L (14.8%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance HIGHER RATE | |
| 5 | L5₹16.0 L+₹2.6 L (19.1%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L5 | Rejected-Finance HIGHER RATE |
Tender Value
Refer Docs
EMD Value
₹37,864
Closing Date
21 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
PROVN OF STORAGE ACCN AT IHQ OF MOD (ARMY) TPT UNIT ASC UNDER GE NEW DELHI
2024_MES_644123_1
NIT No GE/ND-80/2023-24
Open Tender
Civil Works
Item Rate
210 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹37,864
Yes
4 Jun 2024
26 Feb 2024
23 Mar 2024
26 Feb 2024
21 Mar 2024
8 Mar 2024
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc and getting out in soft/loose soil complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) Type A1 of 1:1.5:3 (20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret and the like complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) Type A1 of 1:1.5:3 (20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) Type A1 of 1:1.5:3 (20mm graded crushed stone aggregate) as in beams, cantilevers, bressumm ers, lintels over 1.5m span complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) Type A1 of 1:1.5:3 (20mm graded crushed stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces complete all as specified and directed.
M&L for Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces complete all as specified and directed.
M&L for Use & Waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces complete all as specified and directed.
M&L for Use & Waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces complete all as specified and directed.
S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F of TMT bars 5 mm dia and over upto and including 10 mm dia, as in stirrups, spacers and binders, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan to any radius, built in CM 1:4 as in half brick thick wall complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-0 as in damp proof course to horizontal or vertical surfaces including necessary formwork over 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m. complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Treating the top surface of filled earth at floor at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M& L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base or sub floors finishing the surfaces even and rough to receive the topping layer complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in leveling layer and finishing the top surface even and rough to receive the topping layer or tiling complete all as specified & directed.
M & L for Machine cut Kota Stone slab flooring 18-20 mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing and nosing including 15mm thick scred bed in CM 1:6 complete all as specified and directed.
M & L for Machine cut Kota Stone slab 18-20 mm thick in riser of step, skriting, dado, and pillar and jointed with gray cement slurry mixed with pigment to shade os slab incl rubbing and polishing and rounding to edge of stone slab includig 210 mm thick back coat in CM 1:4 complete all as specified and directed.
Rounding to edges of stone slabs on edge such as in steps,coocking plateform and other similar situations complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:6 on fair faces of concrete /brick surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick cement plastering in cement mortar 1:4 with WPC mixed with cement @200ml/50 kg of cement on fair faces of brick work or concrete surfaces finished even & fair without using extra cement complete all as specified and directed. Note: WPC will be measured and paid seperately
M&L for 5mm thick cement plastering in cement mortar 1:3 as on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquie water proofing compound as per manufacture instruction complete all as specified and directed.
M&L for Preparation of new plastered surface and applying one & more coat of white putty min 1 mm thick on wall surfaces over a coat of chalk whiting priming over tow coat of disteemper oil emulsion complete all as specified and directed.
M & L for prepapation of new plaster serface of walls and applying two coats of acrylic emultion weather coat paint over a coat of primer complete all as specified and directed.
M&L for Preparation of new plastered or unplastered surfaces of ceilinh and applying three coats of white wash on ceiling surfaces complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection laid to slope of 1 in 12 complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded crushed stone aggregate) Slabs supported on walls, beams and columns in canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for: (a) Cleaning the roof surface, remove dust, dirt, loose particles and unsound substrate and grading with cement mortar (1:4), 10 mm thick, as in slab surfaces, beams, columns, parapet, and junction of walls etc., grading with a slope of 1 in 120 mixed with liquid/integral water proofing compound as per manugacturer's instruction as approved by GE (water proofing compound to be measured separately). (b) Applying evenly a tack coat of water proofing shield primer @ 0.50 Kg/ Sqm as a bonding layer over finished plaster surface including cleaning the surface. (c) Over the coat of bitumen bonding layer as above APP modified polymeric membrane (weight not less than 3.0 Kg/Sqm and minimum 3 mm thick einforced with polyester non wove fabric (weight not less than 150 gms/sqm), unrolled and bonded completely to the substrate with side over lap of 5 mm or end over lap of 100 mm. The overlaps are then sealed/ fused by flam technology method as per manufacture instruction. (d) Sealing edges well into grooves & protect with CM 1:2 complete all as specified and directed.
Material & labour cement concrete tiles of size 25 cm x 25 cm x 22 mm thick, machine pressed, set, jointed and pointed in neat cement slurry with grey cement and no pigment in roofs, floors over and including screed bed or bedding layer of cement mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L providing cement concrete as in roof kerbs, levelling courses for making proper gradient/slope or mud stops rounded or chamfered on edges with B-1, 1:2:4 using stone aggregate mixed with water proofing compound as per manufacture instruction including necessary form work complete all as specified & directed. Note: water proofing compound to be measured separately
S&F pressed steel frames for doors of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specefied and as directed.
S & F 30 mm Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F steel window/ventilator Z sec with side hug shutter factory made including projecting type hinge with steel handle and steel peg stay etc. complete with glazing bars complete confirming to Fe 410-0 and making good complete all as specified and directed.
S&F Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
S&F mild steel frame work as in tubular pipes including necessary welding or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width & girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxid primer complete all as specified and directed.
Preparation of New wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 150 mm Stainless steel butt hinges, with stainless steel hinge pin, complete all as specified and directed
S&F 250 mm long Stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixibng Stainless steel bolts and sliding bolts of extruded sections or fixing with stainless steel bolts complete all as specified and directed.
S & F Floor door stopper of stainless steel body and tongue, anodized, with hand drawn steel spring fixed in door, overall length of cover plate 100 mm complete all as specified and directed.
S&F Stainless steel barrel tower bolts of extruded section and fixed 150 mm long complete all as specified and directed.
S&F Stainless steel decorative handles of extruded section and fixed 150 mm long complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil to a distance not exc 50 Mtr & depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed.
S&F PVC pipes single socketed in any length with rubber ring joints and fixing clamps using solvent adhesives fixed to walls with brackets etc of 110mm dia complete all as specified and directed.
S&F PVC (SWR) bends/shoes any radius of 110mm dia complete all as specified and directed.
Surface dressing in soft/loose soil n exc 15cm deep complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base or sub floors or path complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in path, hardstanding complete all as specified and directed.
M&L Sand filling under floors or path or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine vibrated precast concrete interlocking paver/ tiles (glazed finish) with grey cement and pigment any shape, any size, confirming to IS 15658-2006 of 60 mm thick and M-35 grade complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating, as directed and necessary form work complete all as specified and directed.
M&L for Point wiring with 1.5 sqmm, single core ,PVC insulated, sheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/neutral and connected to common earth dolly drawn through and including rigid PVC casing capping of suitable size alongwith fittings and accessories, fixed in walls/ceilings including incl suitable bottom sunk type procced steel terminal box and hylum sheet of suitable modules complete all as specified and directed by Engr-in- charge for the following :-
One light/fan point controlled by one, one way switch complete all as specified and directed.
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board complete all as specified and directed.
All as per item No 61.00 here-in-before but point wiring with 4.0 Sqmm single core copper cable and earth continuity wire with4.0 Sqmm single core cable for one three pin 15 amp socket outlet point on independent board complete all as specified and directed.
S & F Piano flush type switch 6 Amp single pole one way 230V complete all as specified and directed.
S & F Socket outlet flush type 2 in 1, 3 pin, 6A, 230V complete all as specified and directed.
S & F Piano flush type switch 16 Amp single pole one way 230V complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type 230V complete all as specified and directed.
S & F Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
M&LSupply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps to 10 KA rupturing capacity, IS-8828 marked complete all as specified and directed.
S&F MCB DBs single pole with neutral sheet metal enclosures double door type, 240 Volts, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete with out MCB and with enclosures blank plate for unused way suitable fo 8 way including cutting chases and making good to walls complete all as specified and directed.
S&F MCB SPN 240 Volt of capacity 32 to 63 Amp rating, "B" Series complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular size 6 Sqmm complete all as specified and directed.
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI galvanised earth lead wire 4.0mm dia (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc. complete all as specified and directed.
J S CONSTRUCTION CO
M/S MSD & Associate
HANUMAN BUILDERS
A N BUILDERS
BEHAL TRADERS
friends associeates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .