Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹46.5 L+₹3.8 L (8.88%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹47.2 L+₹4.5 L (10.6%)Rejected-AOC | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹48.6 L+₹5.9 L (13.9%)Rejected-AOC | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹48.8 L+₹6.1 L (14.4%)Rejected-AOC | L5 | Rejected-AOC Higher bid value |
Tender Value
₹42.7 L
EMD Value
₹85,360
Closing Date
23 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
PROVN OF SEPTIC TANK AND CONNECTED WORKS UNDER AGE BR I AT RMS
2024_MES_669646_1
8789/C/E8
Open Tender
Civil Works
Item Rate
120 days
RANGAPAHAR
Class D
category a (i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹85,360
13 Nov 2024
2 Sept 2024
25 Sept 2024
2 Sept 2024
23 Sept 2024
16 Sept 2024
2 Sept 2024 - 9 Sept 2024
Amount
M&L for excavation in trenches n.exc 1.5m wide and n.exc 1.5m in deepth; for foundation etc or for shafts, wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and directed.
Excavation over areas n.exc 1.5m deep & getting out soft/loose soil etc complete all as specified and directed.
Excavation over areas exc 1.5m deep but n.exc 3 m deep & getting out soft/loose soil etc complete all as specified and directed.
Excavation over areas exc 3m deep but n.exc 4.5 m deep & getting out soft/loose soil etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering & well ramming in layer s not exc 25 cm etc complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
M & L PCC (1:3:6) type C-2s(using 40mm graded stone aggregate) as in foundation etc and mass concrete etc complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells etc complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells etc complete all as specified and directed.
S&F PVC (SWR) 110mm dia junction single T equal or un equal with an floor etc complete all as specified and directed.
S&F PVC (SWR) 110mm dia bends in any radius etc complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor etc complete all as specified and directed.
S&F of PVC (SWR) 75 mm dia vent cowl pipe as per specification etc complete all as specified and directed.
M & L for brick work in cement mortar 1:4 with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius with old size bricks etc complete all as specified and directed.
Material and labour for brickwork in cement mortar 1:3 with sub class `B' bricks in one brick thick honey comb walling,etc complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
15mm thick cement plaster in cement mortar (1:6) on other than fair face of brick surface finished even and smooth without using extra cement etc complete all as specified and directed.
Supply only integral water proofing compound (ISI marked) etc complete all as specified and directed.
M&L for precast factory made manhole cover/drain covers with plain faces using RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) and set in CM (1:4) including necessary formwork etc of required sizes etc complete all as specified and directed.
M&L for TMT bars 10 mm dia and above, as in reinforcement for concrete, cut to length, bent to shape required including cranking , bending , hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm etc complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia , cut to length, bent to shape required including cranking , bending spirally for hooping for columns, hooking ends as in stirrups, spacers, binders etc and binding with and including mild steel wire(annealed) not less than 0.9 mm or securing with clips etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc complete all as specified and directed.
M&L for RCC nominal mix (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in slabs supported on wall etc complete all as specified and directed.
Cutting into existing manhole/soakwell/septic tank making good to pipe and benching cutting out existing benching for and forming branch channel (half round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for internal dia size 150mm etc complete all as specified and directed.
M & L for PCC type B0 1:2:4 (12.5 mm graded aggregate) as in haunching including weathering, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed.
Supply & fix DWCPE 180 (OD)/150 (ID)mm diameter pipes laid in trenches complete all as specified and directed
M&L for PCC 1:3:6 type C-2 (40mm grade stone aggregate) as in bed to 180 mm dia DWCPE/SWR /PVC pipes including packing under and haunching against the sides of pipes after they are laid and tested.
Supply & fix 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, laid in trenches or in floors and jointed as specified.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in bed to 110 mm dia PVC pipe including packing under and haunching against sides of pipes after they are laid and tested all as specified and directed.
S&F for mild steel conforming to Fe 290-0 Gde-165 in bands, straps, supports or stays for rain water, including bolts, if required, hook and pintle hinges; hand made sliding bolts; clamps; hold fasts; hooks for hanging fans and similar small articles etc complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (40mm graded stone agg) 100mm thick as in sub base etc complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid, jointed with grey cement and no pigment complete all as specified including preperation of formation bed over 25 mm thick sand cusion and pointed in colour cement mortar 1:3 etc complete all as specified and directed.
M&L for chequered cement concrete tiles 200x200x25mm thick with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cement mortar 1:6, etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed.
SHRI RAJNATH SINGH (BID ID -3105867)
MS SADHNA RAHUL (BID ID -3107269)
VIHUTO YEPTHO (BID ID -3106804)
TOSHIKA SUMI (BID ID -3107712)
Kalim sons (BID ID -3107781)
M/S RAHUL TRADING CO. (BID ID -3105819)
awomi enterprises (BID ID -3108641)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .