Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.8 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹64.2 L+₹9.4 L (17.1%)Rejected-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-AOC Other than L1 Bidder | |
| 3 | L3₹65.9 L+₹11.1 L (20.3%)Rejected-AOC | L3 | Rejected-AOC Other than L1 Bidder | |
| 4 | L4₹67.7 L+₹12.9 L (23.6%)Rejected-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L4 | Rejected-AOC Other than L1 Bidder |
| Sl No | Description | Qty | Unit | M/s Trade Linker Associates L3 | M/S PARSHOTAM KUMAR GUPTA L1 | Vijaypower Generators Limited L2 | Roy and Sons Infrastructures L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:-
(a) Capacity 300 KVA
(b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage -360V-480V, Input frequency 50 Hz
(d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1%
(e) Rated frequency - 50 Hz
(f) Wave form distortion - Nil
(g) Response time - not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%
(j) Rate of correction - Not less than 6 Volt/second between phase and neutral
(k) Efficiency - more than 95%
(l) Type of load - three phase, unbalanced type
(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter
(n) Operating temperature - For indoor use upto max ambient temp + 55°C
(o) Dimmer rating - 450 Amp
(p) Dimension of tanks - as per OEM design
(q) Oil capacity- as per OEM design | 1 | Each | 11,30,000 ₹11,30,000 | 5,84,000 ₹5,84,000 | 8,18,100 ₹8,18,100 | 4,40,000 ₹4,40,000 Lowest |
| 1.01(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed. | |||||||
| 2.00 | Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:-
(a) Capacity 100 KVA
(b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage -360V-480V, Input frequency 50 Hz
(d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1%
(e) Rated frequency - 50 Hz
(f) Wave form distortion - Nil
(g) Response time - not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%
(j) Rate of correction - Not less than 6 Volt/second between phase and neutral
(k) Efficiency - more than 95%
(l) Type of load - three phase, unbalanced type
(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter
(n) Operating temperature - For indoor use upto max ambient temp + 55°C
(o) Dimmer rating - 150 Amp
(p) Dimension of tanks - as per OEM design
(q) Oil capacity- as per OEM design | 2 | Each | 4,75,000 ₹9,50,000 | 2,94,000 ₹5,88,000 | 4,66,200 ₹9,32,400 | 2,30,000 ₹4,60,000 Lowest |
| 2.01(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed. | |||||||
| 3.00 | Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:-
(a) Capacity 10 KVA
(b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage -360V-480V, Input frequency 50 Hz
(d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1%
(e) Rated frequency - 50 Hz
(f) Wave form distortion - Nil
(g) Response time - not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%
(j) Rate of correction - Not less than 6 Volt/second between phase and neutral
(k) Efficiency - more than 95%
(l) Type of load - three phase, unbalanced type
(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter
(n) Operating temperature - For indoor use upto max ambient temp + 55°C
(o) Dimmer rating - 32 Amp
(p) Dimension of tanks - as per OEM design
(q) Oil capacity- as per OEM design | 1 | Each | 1,25,000 ₹1,25,000 | 76,500 ₹76,500 | 70,200 ₹70,200 Lowest | 1,00,000 ₹1,00,000 |
| 3.01(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed. | |||||||
| 4.00 | Supply, installation, testing and commissioning of Transformer double copper wound, step down, 11000/433 volts, oil type, minimum 100 KVA capacity or next nearest higher capacity as per OEM design, ONAN, Dyn 11, core type with copper conductor. Transformer shall be provided with Off circuit Rotary type tap switch so as to provided for a voltage adjustment on H.V, from +5% to -5% (in step of 2.5%) of rated voltage of 11000 volts in 4 equal steps (5 position) to obtain rated voltage of 433 volts on LV side including cable box on LT and HT side, with 12 KV system highest voltage at HV side, 28 KV (rms) HV power frequency, 75 kVp HV impulse withstand voltage, trasnformer shall be designed for losses as per IS 1180 (Part-3) : 2021 Efficiency level - II and for 110% continuous overfluxing withstand capaibility, complete with first fill of new transformer oil having dielectric strength not less than 60 KV, suitable mounting arrangement complete and other standard accesssories :
(a) 12KV off circuit tapping switch.
(b) Oil conservator tank with drain plug and filling cap.
(c) Silica gel dehydrating breather charged with silica gel
(d) Oil level gauge.
(e) Oil filter valve.
(f) Oil drain valve.
(g) Thermometer pocket (with oil temp. indicator)
(h) Diagram and rating plate. 1) Two earthing arrangements.)
(j) Lifting lugs.
(k) Four bidirectional plain roller
(l) Air vent plug. | 13 | Each | 3,35,000 ₹43,55,000 | 3,24,851 ₹42,23,063 Lowest | 3,47,100 ₹45,12,300 | 4,31,765 ₹56,12,945 |
| 4.01(m) Explosion vent. (n) Cable box on H.V side. ( 0) Cable box on L.V side. (p) Additional neutral terminal brought outside the LV cable box for earthing. (q) HV&LV cable boxes. (r) Buchholz relay. (s) Radiator valves. ( t) Oil temp. indicator. ( u) Winding temp. indicator ( v) Magnetic oil level gauge. (w) Inspection Cover. (x) marshalling box. all as per IS:1180 (Part 3) : 2014-2021 all as specified and directed. | |||||||
| 5.00 | Disconnecting of LT and HT connection carefully from the existing Transformer of capacity 50 KVA to 100 KVA , 11KV/433 volts of any make/type, taking down/remove from existing site.and shifting by transporting to the MES yard or as directed place by the Engineer-in-Charge.
Note :The quoted rates shall also be deemed to include for all type of tools crane and man power to dismanting and shifting of transformer at palce directed by the Engineer-in-Charge. | 13 | Each | 2,000 ₹26,000 | 500 ₹6,500 Lowest | 5,100 ₹66,300 | 10,000 ₹1,30,000 |
| 6.00 | Disconnecting of incomimg and outgoing connection carefully from the existing servo voltage stabilizer (outdoor/indoor type) of capacity 100 KVA to 300 KVA of any make/type, taking down/remove from existing site.and shifting by transporting to the MES yard or as directed place by the Engineer-in-Charge.
Note : The quoted rates shall also be deemed to include for all type of tools crane and man power to dismanting and shifting of transformer at palce directed by the Engineer-in-Charge. | 3 | Each | 2,000 ₹6,000 | 1,000 ₹3,000 Lowest | 5,100 ₹15,300 | 8,000 ₹24,000 |
Tender Value
₹61.9 L
EMD Value
₹1.2 L
Closing Date
26 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Rajouri
HQ CWE RAJOURI, C/O 56 APO
PROVISIONING OF E and M EQPT AGAINST BER UNDER GE 862 EWS
2025_MES_741800_1
CWE/RAJ-73/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862EWS
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE 862EWS
₹1.2 L
Yes
5 Feb 2026
27 Nov 2025
2 Jan 2026
27 Nov 2025
26 Dec 2025
19 Dec 2025
Amount
Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a) Capacity 300 KVA (b) Type - Suitable for unbalanced load and unbalanced input (c) Input voltage -360V-480V, Input frequency 50 Hz (d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) Rated frequency - 50 Hz (f) Wave form distortion - Nil (g) Response time - not to exceed 20 milli seconds (h) Sensitivity - (+/-) 1% (j) Rate of correction - Not less than 6 Volt/second between phase and neutral (k) Efficiency - more than 95% (l) Type of load - three phase, unbalanced type (m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter (n) Operating temperature - For indoor use upto max ambient temp + 55°C (o) Dimmer rating - 450 Amp (p) Dimension of tanks - as per OEM design (q) Oil capacity- as per OEM design
(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed.
Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a) Capacity 100 KVA (b) Type - Suitable for unbalanced load and unbalanced input (c) Input voltage -360V-480V, Input frequency 50 Hz (d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) Rated frequency - 50 Hz (f) Wave form distortion - Nil (g) Response time - not to exceed 20 milli seconds (h) Sensitivity - (+/-) 1% (j) Rate of correction - Not less than 6 Volt/second between phase and neutral (k) Efficiency - more than 95% (l) Type of load - three phase, unbalanced type (m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter (n) Operating temperature - For indoor use upto max ambient temp + 55°C (o) Dimmer rating - 150 Amp (p) Dimension of tanks - as per OEM design (q) Oil capacity- as per OEM design
(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed.
Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a) Capacity 10 KVA (b) Type - Suitable for unbalanced load and unbalanced input (c) Input voltage -360V-480V, Input frequency 50 Hz (d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) Rated frequency - 50 Hz (f) Wave form distortion - Nil (g) Response time - not to exceed 20 milli seconds (h) Sensitivity - (+/-) 1% (j) Rate of correction - Not less than 6 Volt/second between phase and neutral (k) Efficiency - more than 95% (l) Type of load - three phase, unbalanced type (m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter (n) Operating temperature - For indoor use upto max ambient temp + 55°C (o) Dimmer rating - 32 Amp (p) Dimension of tanks - as per OEM design (q) Oil capacity- as per OEM design
(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed.
Supply, installation, testing and commissioning of Transformer double copper wound, step down, 11000/433 volts, oil type, minimum 100 KVA capacity or next nearest higher capacity as per OEM design, ONAN, Dyn 11, core type with copper conductor. Transformer shall be provided with Off circuit Rotary type tap switch so as to provided for a voltage adjustment on H.V, from +5% to -5% (in step of 2.5%) of rated voltage of 11000 volts in 4 equal steps (5 position) to obtain rated voltage of 433 volts on LV side including cable box on LT and HT side, with 12 KV system highest voltage at HV side, 28 KV (rms) HV power frequency, 75 kVp HV impulse withstand voltage, trasnformer shall be designed for losses as per IS 1180 (Part-3) : 2021 Efficiency level - II and for 110% continuous overfluxing withstand capaibility, complete with first fill of new transformer oil having dielectric strength not less than 60 KV, suitable mounting arrangement complete and other standard accesssories : (a) 12KV off circuit tapping switch. (b) Oil conservator tank with drain plug and filling cap. (c) Silica gel dehydrating breather charged with silica gel (d) Oil level gauge. (e) Oil filter valve. (f) Oil drain valve. (g) Thermometer pocket (with oil temp. indicator) (h) Diagram and rating plate. 1) Two earthing arrangements.) (j) Lifting lugs. (k) Four bidirectional plain roller (l) Air vent plug.
(m) Explosion vent. (n) Cable box on H.V side. ( 0) Cable box on L.V side. (p) Additional neutral terminal brought outside the LV cable box for earthing. (q) HV&LV cable boxes. (r) Buchholz relay. (s) Radiator valves. ( t) Oil temp. indicator. ( u) Winding temp. indicator ( v) Magnetic oil level gauge. (w) Inspection Cover. (x) marshalling box. all as per IS:1180 (Part 3) : 2014-2021 all as specified and directed.
Disconnecting of LT and HT connection carefully from the existing Transformer of capacity 50 KVA to 100 KVA , 11KV/433 volts of any make/type, taking down/remove from existing site.and shifting by transporting to the MES yard or as directed place by the Engineer-in-Charge. Note :The quoted rates shall also be deemed to include for all type of tools crane and man power to dismanting and shifting of transformer at palce directed by the Engineer-in-Charge.
Disconnecting of incomimg and outgoing connection carefully from the existing servo voltage stabilizer (outdoor/indoor type) of capacity 100 KVA to 300 KVA of any make/type, taking down/remove from existing site.and shifting by transporting to the MES yard or as directed place by the Engineer-in-Charge. Note : The quoted rates shall also be deemed to include for all type of tools crane and man power to dismanting and shifting of transformer at palce directed by the Engineer-in-Charge.
Disconnecting of incomimg and outgoing connection carefully from the existing servo voltage stabilizer (outdoor/indoor type) of capacity 10 KVA of any make/type, taking down/remove from existing site.and shifting by transporting to the MES yard or as directed place by the Engineer-in-Charge. Note : The quoted rates shall also be deemed to include for all type of tools crane and man power to dismanting and shifting of transformer at palce directed by the Engineer-in-Charge.
Vijaypower Generators Limited (BID ID -3508859)
M/s Trade Linker Associates (BID ID -3507734)
Roy and Sons Infrastructures (BID ID -3508897)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_830657.xls
BOQ • 0.24 MB
Tender.pdf
Tender Documents • 1.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .