Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹71.4 L+₹1.9 L (2.70%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹82.8 L+₹13.3 L (19.1%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | L4₹87.0 L+₹17.4 L (25.1%)Rejected-Finance | L4 | Rejected-Finance Being not lowest tenderer | |
| 5 | L5₹94.0 L+₹24.5 L (35.2%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L5 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹72.8 L
EMD Value
₹1.3 L
Closing Date
2 Nov 2023, 6:00 pmClosed
HQ CWE AF TUGHLAKABAD
HQ CWE AF TUGHLAKABAD AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
PROVN OF PU FLOORING IN CERTAIN BUILDINGS AT AF STN UNDER GE (AF) TUGHLAKABAD
2023_MES_621078_1
CWE/TKD-50 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Tughlakabad
As per NIT condition
8 documents required · 8 mandatory
₹1,000
GE (AF) Tughlakbad
₹1.3 L
Yes
27 Dec 2023
29 Sept 2023
4 Nov 2023
29 Sept 2023
2 Nov 2023
19 Oct 2023
Amount
M & L for 6 mm thick EPU floor coating system including surface preparation by preparing the concrete surface by shot blasting or scarifying or diamond grinding equipment to remove any loose materials, contaminants and laitance to provide a sound, fine gripping surface, and then opening the cracks above 1mm and cold joints and filling with epoxy mortar and cleaning the floor area using a powerful industrial vacuum cleaner. Over the prepared surface, solvent free epoxy primer of Cipoxy 16/17 or equivalent is applied as a high build moisture tolerant epoxy primer for a thickness of 200 microns. A self-levelling epoxy screed using Cipoxy 17/15 with graded aggregates with a thickness of 3700 microns shall be applied. On the screed surface, self-adhesive copper tape of conductive grade, of thickness 100 microns and 25mm in width shall be positioned in a grid form 10.0M C/C in both directions, are stuck and connected to a permanent earth ground such as for every 300 sqm one Earthing point. Conductive coat of Aquoxy ESD of Cipy, which forms the electrical plane through which static charges are dissipated, shall be applied at a thickness of 100 microns, followed by a conductive grade Epoxy self-levelling flooring, Statguard ESD 104 of Cipy or equivalent, shall be applied at a thickness of 2000 microns. The coated layer is deaerated by using a spike roller evenly and smoothly, so that carbon fibres are equally distributed across the area. Note:- (i) The quoted rate shall be inclusive of all the works. (ii) Work to be carried out as directed by Engr-in-charge (iii) The contractor shall submit purchase voucher from the approved manufacture. The Engr-in-Charge shall verify the same and fwd to E-8 section of GE duly defaced for claiming payment by the contractor. Non-submission may lead to non-payment. (iv) All demolished material removed from MOD land completely distance exe 5 km. (v) The prepared area shall be neatly cleaned. The work shall be carried out through authorised applicatot. The approval of Authorised applicator shall be approved by GE under the intimation of Accepting Officer.
Providing and fixing 4.5 mm thick (minimum) heterogeneous Linoleum vinyl flooring of approved make including skirting, in required colour, profile and pattern of specified approved make of required size as per the site conditions, etc. all complete. The flooring to be fixed and jointed by using approved adhesive as per manufacturer's specifications and as per direction of Engineer-in-Charge. All visible joints on flooring shall be sealed as per the manufacture's specifications to make the floor seamless complete all as specified and directed. NOTE:- (i) The floor shall be dried and levelled with self-levelling material. (ii) The contractor shall submit purchase voucher from the approved manufacture. The Engr-in-Charge shall verify the same and fwd to E-8 section of GE duly defaced for claiming payment by the contractor. Non-submission may lead to non-payment.
Demolition of cement concrete un reinforced in ground floors and pavings of any thickness complete all as specified and directed..
M&L cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, cement ramp with "trimix flooring using vacuum dewatering method and power traweling with skim floter complete all as specified and directed.
S &F Aluminium dividing strips, 38mm wide, 1.5mm thick and inserted in position to conform to design complete all as specified and directed.
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate in mass concrete, copings, kneelers, apex stones, slightly rounded for chamfered angles and throating complete all as specified and directed.
M&L Formwork to edges of flat surface concrete , breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening for rough finished surface complete all as specified and as directed.
S&F in repairs upto 150 mm cast iron soil rain water pipes in any length with or without ears with cement joints fixed to walls/floor complete all as specified and directed.
S&F 150 mm bore CI Bends (any radius) with duck's foot or heel rest (ISI marked), complete all as specified and directed.
S & F supporting angles, Bands, straps, supports or stays for cable ducting, ventilating pipes, similar small articles conforming to Fe290 or Gde E-165 complete all as specified and directed.
S & F Plates (plain or chequered) Square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W(Gde-E-250) quality-B complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coasts of synthetic enamel paint over one coat of red oxide primer (for steel surfaces) complete all as specified and directed.
M&L for 15 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of brick wall/floor or concrete surfaces finished even and smooth, (without using extra cement) including taking down complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper of approved tint over a coat of 1 mm thick wall care putty as a primer complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight of curved on plan exceeding 6M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for replacement of gear box of steel rolling shutter including handle rack & pinion system, ball bearing, End Cap, Aluminium Box Top Octagonal Tube Security Spring etc for rolling shutter of size exceeding 5 sqm but not exceeding 25sqm each to make it serviceable Including minor repair complete all as specified & directed.
Material & labour for providing & applying Polyurethane Cipy make primer Duraprime and sealant Episeal in Expansion joints. It includes cut open the joints, removal of debris etc. and laying Cipy make Episeal in the Expansion joints 25mm x 20mm complete all as specified and directed.
Material & labour for providing & applying Polyurethane Cipy make demarcation system with FK 666/ FPG 700 on coated surface complete all as specified and directed.
Supply and laying synthetic rubber insulation mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-20006,(Superseding IS 5424 ) suitable for electrical shock safety of size 2 m x 1 m complete all as specified and directed.
S&F MS sheet 0.5 mm thickness for covering LT Panels Angle Girder Portion complete all as specified and directed.
S&F duct cover 2 m x 65Cm x 5mm complete all as specified and directed.
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, back and front both side opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:-
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:-
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:-
S&f Duct Cover 1m x 65cm x 5mm complete all as specifed and directed.
Taking out heavy duty MS duct cover 1.2 m x 0.7 m x 0.008m or weighing upto 80 kg for taking out old unsv cable and refixing the duct cover after taking unsv and refixing the same of any size and capacity in the duct complete all as specified and as directed.
Supply, laying in replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed.
Supply, laying in replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying in replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying in replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Taking down old unsv LT feeder panel after dissconnecting cable and necessary fastening elements with safety complete all as specified and directed
Schedule of Credit
Leo Network power systems
M/s KUMAR BUILDERS
M/S S.K.Electricals
V r traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .