SE ETC ALIGARH
LAL DIGGI ALIGARH
Construction of 02 Nos 220 KV bays at 220 KV Switchyard Harduaganj Thermal Power Station for 220 KV Khair Harduaganj DC line under ETD I Aligarh
2023_UPTCL_857917_4
SHORT TERM ETC- 18/2023-24
Open Tender
Electrical Works
Item Rate
120 days
ALIGARH
Please refer tender document
2 documents required · 2 mandatory
₹2,950
SE ETC ALIGARH
₹16,000
15 Feb 2024
20 Jan 2024
13 Feb 2024
20 Jan 2024
12 Feb 2024
20 Jan 2024
Amount
Erection of structures like CTM, DTM, ETM, FTM, GTM, BCT & ALP. As per technical specification including shifting from store to erection site including all associated works for completion of erection works satisfactorily.
Erection of following equipments as per instuction manual of various equipments & technical specifications including shifting from store to erection site with all associated works for satisfactory completion of erection works
245 KV CT (CTR = 800:1)
245 KV CT Junction box
245 KV Tendem isolator
245 KV CVT
Post insulator
Lightening Arrestors 198 KV
Erection of Control and Relay panel including making all connections ,earthing including all connected works as per direction of supervising engineer for satisfactory complition of works
Cutting straightening and laying 1000 mm below inside & above ground of 50*6, 75*10 mm size MS flat (to be provided by department free of cost as per requirement) for earthing of main and auxiliary structures, equipments & cable trenches including welding with main earth mate and with the object to be earthed, excavations of trenches, its back filling, painting and all other associated works to complete the earthing work satisfactorily as per technical specifications.
earthing of auxiliary structures and equipment with 50*6 mm MS flat
earthing of auxiliary structures and equipment with 75*10 mm MS flat
Jumpering of equipments of Bays with the help of Moose conductor between 220 KV main bus, transfer bus, transfer bus and jumpering between conductors with suitable clamps and conductors.
Auxiliary Earthing of 198KV LA’s consisting of febrication of delta set with 6nos. 40mm dia size 3 Mtrs long electrodes its placing inside the ground and connecting all the electrodes with 40 mm round bar and connecting the same with earthmat at two places (M.S flat and M.S round to be provided by the Department ).
Laying of following size of control cable in cable trenches from control and relay panel in control room to various equipments, junction boxes etc in switchyard as per cable schedule, its saddling including carriage of cable drums from store to work and shifting back to store with all associated work to complete the job as per technical specifications:-
Preparation of interconnection cable schedule of 220 bay and panels, termination of control cable as laid above as per cable schedule including making necessary holes in gland plates or boxes of appropriate size and providing ferruls for each core of cables its termination with crimping type logs and all associated works to complete the job satisfactorily as per technical specifications.
Providing and fixing new generation energy saving & environment friendly long life versatile pressure die-cost aluminium outdoor high beam flood source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V AC supply of IS make of CGL/Havells/Phillips/Bajaj etc. brand
Providing and fixing of junction box of 16 SWG MS sheet duly painted size 150*150*200 mm for above light on the bottom of main structure with the help of clamps, junction fix contains 01 no. 05 Amp single pole MCB ( L&T, Havells, Siemens make ) with 01 no. link as per technical specifications
Providing and fixing of phase plate ( R,Y,B )
Laying, dressing and termination of control cable for the gantry light with the help of clamps,vertically on gantry & all other associated work.
Providing and fixing of name plates for various equipments make of 2 mm thick aluminium sheet with covering of 03 mm retro reflective sheet with various size .
Dismantling of tower structure used for lighting present in front of bay no. 16 at HTPS(GTM & FTM) and old BBL,BCT and shifting the material in store.
Integration of newly contracted Bay with existing Data Logger and SCADA system if any
Integration of newly constructed Bay with existing Bus Bar protection System
Supply and connection of Bus Bar insulators
Single tension fitting for single moose
Single suspension fitting for single moose
PG clamp moose-moose
Run through clamp for moose
Silicon rubber suspension string assembly 70KN
Silicon rubber tension string assemble 160kN
Isolator clamp for moose conductor
M/s S.S. Refregeration
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .