| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Lowest one | |
| 2 | L2₹47.8 L+₹12.0 L (33.6%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹50.2 L+₹14.4 L (40.3%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹50.3 L+₹14.5 L (40.6%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹52.4 L+₹16.6 L (46.5%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF MISC EM ITEMS VARIOUS TYPE RECESS MOUNTING LIGHTING FITTINGS LIGHTENING ARRESTORS FAULTY CABLES AND OTHER EM ITEMS FOR OUTLAYING AREA UNDER GE NW NOFRA
2021_MES_492971_1
8987
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Mumbai
As per tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹99,000
Yes
1 Feb 2022
7 Dec 2021
6 Jan 2022
7 Dec 2021
3 Jan 2022
21 Dec 2021
7 Dec 2021 - 20 Dec 2021
30 days
Amount
Taking up/out old U/S XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking up Old concrete cable cover from trenches/walls/ceiling/poles etc any size all as specified and directed
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, laying of UG Electric cable / staying of steel tubular pole etc. and getting out in soft and loose soil/ hard soil, complete all as specified and as directed .
M & L for Cutting existing road surface or hard standing 0.30 mtr depth using latest technology for laying of pipes/ cables and making good distrubed surface to match with existing complete with PCC all as specifed and directed by Engineer - in - Charge
Removing the excavated material/ soil not exc 50m out of MD land complete all as specified and directed .
Returning & filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm as in soil complete all as specified & directed .
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 80mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 110mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
supply & Fixing and laying of PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 50 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
Supply & Fixing and laying of PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 70 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
supply & Fixing and laying of PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 95 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
supply and Fixing and laying of PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 120 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
supply & Fixing and laying of PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 185 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
supply and Fixing and laying of PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 240 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
supply and Fixing and laying only PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 300 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Make- Polycab / Finolex / Asian (RPG)/Havells/KEI
supply and Fixing of PVC baton intergrated LED light fitting channel 1 x 20WH any colour as required at site accessories internally prewired complete set and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . make : havells/ philips / jaquar / wipro
Taking down old unserviceable recess mounting tube light from POP falls/ tails ceiling. Supply and Replacement LED light 2 x 2 feet panel 36 Watts LED luminary back lit recess mounting , CRCA housing white powder coated, with decorative polymer diffuser complete with accessories locking arrangement, clips , per wire for connection and fixing in falls ceiling making matching with existing surface etc all as directed by Engr -in-Charge. make : Havells/ philips / jaquar / wipro
M & L for Painting with of LT panels of any size and type including one coat of primer paint all including scrapping out the old paint by scrubbing and application of primer before double coat of paint including minor repair like welding of hinges, repairing of lock and key arrangements all as specified and directed by Engineer - in - Charge.
M & L for servicing of LT panel including dismantling the old cable lugs by cutting the cable, meggering the cables with help of megger and detecting any fault/short circuit if any including fixing of new lugs by pealing the cable, cutting and joing the cables with the help of Cable Joint Kit of suitable size if required, servicing of MCCBs/MCBs/Bush Bar/ Checking/Replacing of Nut Bolts etc. all as specified and directed by Engineer in Charge. Note: i) The items i.e. MCCBs/MCBs, Cable Joint Kit of suitable size, Painting Job of Panel shall be measured and paid seperately under various item. ii) The material and labour required for servicing of LT panel i.e consumables/nut bolts etc shall be deemed to be included in the item rate.
M & L for Locating the cable fault in UG LT cable of size ranges upto 35 sqmm to 300 Sqmm and joining the cable with the help of cable joint kits of suitable size including excavation at the location of cable fault and return filling of the excavated material after joing the cable all inclusive all as specified and directed by Engineer - in - Charge. Note: i) The rate quoted shall be deemed to included the cost of fault locator if required. ii) The rate quoted shall be deemed to be included the cost of excavation and refilling etc
Taking down old unserviceable street light of any capacity from existing pole of any size and re fixing only street light of any capacity after carrying out minor repair / replacement of burnt cable / cleaning etc compolete all as specified and directed.
Supply, install, testing and commissioning of LT Feeder Pillar CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type, with front side opening Minimum size 1.2 x 1.0 x o.60 mtr mm or suitable fixing of all breakers and controls for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- Make of MCCBs/ACBs/Changeover: Legrand / Schneider / L&T
(a) ON Load LT Changeover , 4 POLE, 400 Amps Make: Legrand/Havells/L & T
(b) MCCB 400 Amps, 36 KA, FP - 01 Nos Make: Legrand Cat Part No. 4220 35 of model DPX3 400/ L & T/ABB/Havells
(c) MCCB 250 Amps, 36 KA FP - 05 Nos Make: Legrand Cat Part No. 4202 49 of model DPX3 250/ L & T/ABB/Havells
(d) MCCB 160 Amps, 36 KA, FP - 02 Nos Make: Legrand Cat Part No. 4200 97 of model DPX3 160/ L & T/ABB/Havells
(f) Aluminium bus bar 600 Amps for phase & 400 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
(g) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
Supply, install, testing and commissioning of LT Panel CPRI Approved mounted on angle iron frame 100 x100x 6 mm grouted on floor,cubical indoor type, with both side opening Minimum size 2.5 x 2.0 x 0.80 mtr or suitable fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 1200 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new installed panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- Make of MCCBs/ACBs : Legrand / Schneider / L&T
(a) LT ACB , 4 POLE ,DRAW OUT 800Amps, 100A - 02 Nos (INCOMING) Make: Legrand CAT Part No. 6695 42 of Model No. DMX SP - 2500 or Equivalent in L & T/ ABB/Havells
(b) LT ACB , 4 POLE ,DRAW OUT 400 Amps, 50A - 02 Nos (OUTGOING ) Make: Legrand CAT Part No. 6695 42 of Model No. DMX SP - 2500 or Equivalent in L & T/ ABB/Havells
(c) MCCB 350 Amps, 36 KA FP - 06 Nos Make: Legrand Cat Part No. 4202 49 of model DPX3 250/ L & T/ABB/Havells
(d) MCCB 400 Amps, 36 KA, FP - 02 Nos Make: Legrand Cat Part No. 4220 34 of model DPX3 630/ L & T/ABB/Havells
(e) MCCB 250 Amps, 36 KA FP - 03 Nos Make: Legrand Cat Part No. 4202 48 of model DPX3 250/ L & T/ABB/Havells
(f) Bus coupller of 800 Amps -01 for transformer 1 & 2 . Make : L & T/ ABB/Havells
(h) Aluminium bus bar 1200 Amps for phase & 800 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
(j) Aliminium bus bar connected one side of MCCB /ACB / Bus coupler as per capacity MCCB and MCCB and ACB fixed in vertical position
(k)Digital Ammeter-04 No, Make-HPL ,SP CL-1.0/AE
(l)Digital Voltmeter-04 No Make-HPL ,SP CL-1.0/AE
(m) Phase indicator lamp R,Y & B with slector switch- 12 N0
(n) Aluminium bus bar connected one side in each MCCB /ACB / Bus coupler and MCCB and ACB fixed in vertical position
Supply & Fixing Cable Straight Joint Kit / out door cable end joint kit / indoor cable end joint kit of heat shrinkable type of following size complete all as specified and directed by Engineer - in - Charge. Make: 3M/Raychem or equivalent
(i) 400 Sqmm & above size
(ii) 240 to 300 Sqmm
(iii) 150 to 185 Sqmm
(iv) 70 to 120 Sqmm
(v) Upto 50 Sqmm
S & F MCCB 400A ,4P,415 volts breaking capacity 36 KA as per existing model at site incl all necessary fixing arrangements , addtion / altration of Panel , cuuting welding etc if required all as specified and directed by Engineer - in - Charge. Make: Legrand/ L & T/ABB/Havells/Standard/ Indoasian.
S & F MCCB 250A, 3P, 415 volts breaking capacity 25 KA as per existing model at site incl all necessary fixing arrangements , addtion / altration of Panel , cuuting welding etc if required all as specified and directed by Engineer - in - Charge. Make: Legrand / L&T/ABB/Havells/Standard/ Indoasian.
S & F MCCB 200A 3P,415 volts breaking capacity 25 KA as per existing model at site incl all necessary fixing arrangements , addtion / altration of Panel , cuuting welding etc if required all as specified and directed by Engineer - in - Charge. Make: Legrand / L&T/ABB/Havells/Standard/ Indoasian.
S & F MCCB 160 A ,3P,415 volts breaking capacity 25 KA as per existing model at site incl all necessary fixing arrangements , addtion / altration of Panel , cuuting, welding etc if required all as specified and directed by Engineer - in - Charge. Make: Legrand / L&T/ABB/Havells/Standard/ Indoasian.
S & F MCCB 100 A ,3P,415 volts breaking capacity 25 KA as per existing model at site incl all necessary fixing arrangements , addtion / altration of Panel , cuuting, welding etc if required all as specified and directed by Engineer - in - Charge. Make: Legrand / L&T/ABB/Havells/Standard/ Indoasian.
S & F MCCB 63 A, 3P,415 volts breaking capacity 25 KA as per existing model at site incl all necessary fixing arrangements , addtion / altration of Panel , cuuting, welding etc if required all as specified and directed by Engineer - in - Charge. Make: Legrand / L&T/ABB/Havells/Standard/ Indoasian.
Supply, install, testing and commissioning of LT Feeder Pillar CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type, with front side opening Minimum size 1.2 x 1.0 x o.60 mtr mm or suitable fixing of all breakers and controls for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- Loc - NT Pool / DSC line Make of MCCBs/ACBs : Legrand / Schneider / L&T
(a) Motor star delta starter suitable for UPTO 12.5 HP motor - 02 Nos
(d) MCCB 250 Amps, 36 KA FP - 01 Nos Make: Legrand Cat Part No. 4202 49 of model DPX3 250/ L & T/ABB/Havells
(f) MCCB 100 Amps, 36 KA, FP - 04 Nos Make: Legrand Cat Part No. 4200 97 of model DPX3 160/ L & T/ABB/Havells
(h) Aluminium bus bar 400 Amps for phase & 200 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
(j) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
(e)Digital Ammeter-03 No, Make-HPL ,SP CL-1.0/AE
(f)Digital Voltmeter-03 No Make-HPL ,SP CL-1.0/AE
(g) Phase indicator lamp R,Y & B with slector switch - 03 Set
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated of mimimum size 2.5 x 2.0 x 0.6 Mtr CPRI approved, front side open hinged door with locking arrangement powder coated and front door glass fitted for checking of meter reading individual compartment for MCCBs and 400 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- (a) Motor star delta starter suitable for UPTO 12.5 HP motor - 02 Nos (b) MCCB 250 Amps, 36 KA FP - 01 Nos Make: Legrand Cat Part No. 4202 49 of model DPX3 250/ L & T/ABB/Havells
(a) MCCB, FP, 250 Amps 25 kA- 01 Nos. Make-Legrand / Schneider / L&T/HAVELLS/ABB
(b) MCB 63 Amps, 10KA, C series - 30 NoS . Make-Legrand / Schneider / L&T / HAVELLS /ABB
(c) Sheet metal enclosure 2 way without bus bar - 12 No, Make-Legrand / Schneider / L&T
(d ) Aluminium Bus bar, 400 Amps Rated - R,Y,B & N
(e)Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE
(f)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE
(g) Phase indicator lamp R,Y & B with slector switch
(h) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 30 Nos. ( Note : Cost included Refixing old Electric Meter )
(j) Material and labour for 2 core 10 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads.
(k) Fixing of submain cable 2 core 10 Sqmm copper conductor with outgoing of energy meter all as directed.
M&L for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 weatering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
M&L in replacement Earth continuity conductor for lighting conductor or as main earthing lead for earthing fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm .
Supply and fixing of in repair 1x 50 sqmm copper multi strandard conductor with 0.5 mm thick PVC sheathed cable complete all as specified and directed.
Securing of hanging and loose electrical cable & taking up loose cable from wall, pole , roof and refixing XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cables upto 06 Nos of sizes from 06 Sqmm 2 Core to 185 Sqmm 3.5 core complete fixed on wall pole , roof properly with suitable Plastic strep cable Zip ties nylon self locking wire ties black 250 mm and galvanised 'U' clamps with anchor fastner or saddles and screws all as specified and directed.
Supply and fixing in replacement chequered plate 6 mm thick and cut to cable duct size & shape machined properly on sides incl apply red oxide prime with two coats of painting and provide for cable duct protection complete all as directed by Engineer -in-Charge
Supply and fixing in replacement equal 45 x 45mm and 5 x 50 mm angle iron 4 mm thick and cut to cable duct frame complete all as directed by Engineer -in-Charge
Disconnect electric connection and taking out existing service cable from the cable duct and cleaning sand /mud /other items after cleaning reconnect the service cable and checking electric supply in each Qtrs complete all as directed by Engineer -in-Charge Note : Cable duct from meter room & Bldg Shaft - 02 Bldg
S&F Replacement in made of 3 mm thick CRCA sheet weather, vermin proof fabricated for replacement of LT Panel doors of front and back side as required shape and size as per at site and reaplacement of hinges / locking arrangements incl wedling , painting of red oxide primer and two coats of synthatic paint of all surfaces of LT Panel , complete all as specefied and directed by Engineer -in-Charge.
S&F LED LAMP 7 watt /9 watt, 230 volts of warm white / milk white of any colour / model etc as required at site incl taking down old lamp any type complete all as specefied and directed. Make: crompton/ bajaj/havells / wipro/C&S/PHILIPS as required make at site.(Location : WNC(O) Mess/ nofra/outlaying md area/ins shikara)
S&F LED LAMP 10 watt to 14 watt 230 volts of warm white / milk white of any colour / model etc as required at site incl taking down old lamp any type complete all as specefied and directed. make: crompton/ bajaj/havells / wipro/C&S/PHILIPS as required make at site. (Location : WNC(O) Mess/ nofra/outlaying md area / ins shikara)
Taking down old unserviceable qnd burnt out sub main from the esixting position ground floor to 15 floor . Supply and fixing Submain wiring with proper colour coding, 2 core FRLS 1100 Volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping of suitable size not less than 25 mm including 1 single core cable with stranded copper conductor of size 10 Sqmm (green colour) for earthing. Make of cable: Plaza/ Havelles/Finolex. Make of PVC Casing caping : Finolex/ Precision/ Plaza Note : 2 runs of 10 Sqmm cable, 1 run of PVC Conduit and 1 run of 10 Sqmm cable shall be measured as 1 Run.
Taking down old unserviceable qnd burnt out sub main from the esixting position ground floor to 15 floor . Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in and including PVC casing caping /conduit of suitable dia 20 and 25 mm, ISI marked including 1 single core cable with stranded copper conductor of size 6 sqmm (green colour) for earthing. Make : Polycab, Havells, Plaza, Finolex Note :- (i) Two runs of 6 Sqmm cable, 1 run of PVC casing caping / PVC conduit and 1 run of 6 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC conduit/ casing and caping as per site requirment
NOEL ENGINEERS
SHREE JAGDISH FURNITURE CO.
BOB ENTERPRISES
OM SAI POWER SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .