| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 12 1 1 PUDHUSAMPALLI RAMAN NAGAR POST METTUR DAM 636 403 | METTUR DAM | SALEM | TAMIL NADU | 636403 | ₹4.0 L Quoted ₹3.6 L | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Fee/PreQual/Technical 21 CHAKRADHAR SOCIETY OLD SAIKHEDA ROAD NEAR MARUTI WAFERS NASHIK DWARKA MAHARASHTRA NASHIK MAHARASHTRA 422011 UDYAM MH 23 0003690 | NASHIK | MAHARASHTRA | 422011 | - | - | Not Admitted-Fee/PreQual/Technical Others-EMD and BQR not satisfied |
| Sl No | Description | Qty | Unit | V PALANIVELU CONTRACTOR L1 |
|---|---|---|---|---|
| 1.00 | Charges for removal of local pressure gauges / temperature gauges and refixing them after calibration in Turbine & Generator areas. | 50 | Nos | 430 ₹21,500 |
| 2.00 | Charges for Removal of pressure/ Vacuum/flow switches and refixing them after calibration in Boiler Turbine and Generator areas. | 30 | Nos | 430 ₹12,900 |
| 3.00 | Charges for removal of existing transmitters incl. disconnecting the control cables, removal of clamps & manifold and refixing them after calibration in Boiler, Turbine & Generator areas. | 10 | Nos | 430 ₹4,300 |
| 4.00 | Charges for dismantling, cleaning & replacement of gaskets and re-fitting of level switches. | 32 | Nos | 2,200 ₹70,400 |
| 5.00 | Charges for cutting of existing flange from stand pipe (4.5 inch) of HP Heater 3&4 level transmitter and Gland Cooler II stand pipe, grinding the surface in stand pipe, Welding of new flange in the stand pipe, providing new metallic gasket for new flange, fixing of new Guided wave radar transmitters. | 2 | Nos | 2,600 ₹5,200 |
| 6.00 | Charges for removing and refitting of accessories in pneumatic control valves & dampers such as E/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing and receiving the tested instruments from lab. | 40 | Nos | 1,800 ₹72,000 |
| 7.00 | Charges for Replacement of HAD/CAD cylinder (8" Bore and 8 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting andunloading of new pneumatic cylinder from central/local store to field location.iii) Fixing the new pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings. | 2 | Nos | 5,500 ₹11,000 |
| 8.00 | Charges for Replacement of burner tilt cylinder(10" Boreand 16 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store. ii) Loading, transporting and unloading of new pneumatic cylinder from central/local store to field location.iii) Fixing the new pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings. | 1 | Nos | 6,800 ₹6,800 |
| 9.00 | Removing the terminal connections, Replacing the broken terminal blocks and reconnecting the terminal connections and checking in Various Junction boxes at Boiler, turbine and mill area. | 250 | Nos | 50 ₹12,500 |
| 10.00 | Charges for rectification and welding of broken doors in junction boxes. | 20 | Nos | 600 ₹12,000 |
Tender Value
Refer Docs
EMD Value
₹3,500
Closing Date
11 Aug 2025, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPS-I ES Circle- CI Uni-IV Removal and refixing of pressure Temp gauges, Turbine casing Thermocouples, RTDs , Transmitters and switches after calibration, Replacement of gaskets for displacement type transmitters and level switches,Cleaning of all
2025_EB_585889_1
CE-MTPS-I-SE-ES-CI-OT55-25-26
Open Tender
Electrical Works
15 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹3,500
Yes
9 Mar 2026
26 Jul 2025
12 Aug 2025
26 Jul 2025
11 Aug 2025
26 Jul 2025
Amount
Charges for removal of local pressure gauges / temperature gauges and refixing them after calibration in Turbine & Generator areas.
Charges for Removal of pressure/ Vacuum/flow switches and refixing them after calibration in Boiler Turbine and Generator areas.
Charges for removal of existing transmitters incl. disconnecting the control cables, removal of clamps & manifold and refixing them after calibration in Boiler, Turbine & Generator areas.
Charges for dismantling, cleaning & replacement of gaskets and re-fitting of level switches.
Charges for cutting of existing flange from stand pipe (4.5 inch) of HP Heater 3&4 level transmitter and Gland Cooler II stand pipe, grinding the surface in stand pipe, Welding of new flange in the stand pipe, providing new metallic gasket for new flange, fixing of new Guided wave radar transmitters.
Charges for removing and refitting of accessories in pneumatic control valves & dampers such as E/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing and receiving the tested instruments from lab.
Charges for Replacement of HAD/CAD cylinder (8" Bore and 8 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting andunloading of new pneumatic cylinder from central/local store to field location.iii) Fixing the new pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings.
Charges for Replacement of burner tilt cylinder(10" Boreand 16 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store. ii) Loading, transporting and unloading of new pneumatic cylinder from central/local store to field location.iii) Fixing the new pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings.
Removing the terminal connections, Replacing the broken terminal blocks and reconnecting the terminal connections and checking in Various Junction boxes at Boiler, turbine and mill area.
Charges for rectification and welding of broken doors in junction boxes.
Charges for opening and cleaning of all impulse lines and catch pots in mills, Flue gas, primary and secondary air paths.
Charges for cutting and welding of takeoff catch pots in mills, flue gas, primary and secondary air path.
Charges for replacement of defective 1” root valve in HP/LP Heaters which involves the cutting and welding of 2 joints in 1” CS Impulse line .
Charges for replacement of defective drain valve (3/8”) for high-pressure transmitter.
Charges for removing existing leaky 3/8” SS impulse line and worn out connectors, cutting and bending the new line as necessary, fixing SS connectors with nut and ferrule in the line and connecting back the new line without leaks in high pressure transmitters.
Charges for removal and refixing of all types of RTD/thermocouples.
Charges for Overhauling of Servo valves for HP/LP bypass system.
Copper Washer (Sl.No:1)
Teflon O-ring (Sl.No :3 )
Gasket (Champion 54 grade / Klinger 1000 grade) size 280 x 280 mm. (Work Sl.No:4)
Gasket (Champion 54 grade / Klinger 1000 grade) size 240 x 240 mm. (Work Sl.No:5)
2.5 Sq.mm Elmax Terminal Block (Work Sl.No:9)
2.5 mm CS welding rod electrode (90 Nos./Box)(Work Sl. Nos: 5,10,12,13,14)
Gas cutting for takeoff catch pot and 1/2” impulse line.(Work Sl. Nos: 5,10,12,13,14)
High pressure drain valve. (Work Sl.No:14)
Pad lock & Hinge (Work Sl.No:10)
Charges for consumables such as Teflon Tape, PVC Insulation tape, Cotton Waste, Emery Sheet,Glass putty, Rustolene, bolt and nuts, Anabond, etc. (Work Sl. No.: 1 to 17)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid