Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹9.1 L+₹22,349 (2.52%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹10.4 L+₹1.5 L (16.6%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
26 Jan 2022, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8624REPAIRS AND MAINT OF MOTOR BELTS AND OTHER ALLIES ITEMS AT UNDER KLD STP AT AFTC UNDER GE M AF JALAHALLI BANGALORE
2021_MES_498146_1
8624/e8
Open Tender
Civil Works
Item Rate
182 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹20,000
11 Mar 2022
29 Dec 2021
28 Jan 2022
29 Dec 2021
26 Jan 2022
12 Jan 2022
29 Dec 2021 - 5 Jan 2022
Amount
M&L for repair and servicing to squirrel cage induction motor 3 phase 415V, 7.5 HP Kirlosker make by dismantling of motor from the pump set removing the starter/rotor separately, cleaning, varnishing, heating and drying re-erecting, aligning with the pump, testing, including replacement of nuts , bolts and washers, bearings of suitable size all as directed by Engineer-in-charge.
All as per item No 1 but of squirrel cage induction motor of cap 1.5 HP.
All as per item No 1 but of squirrel cage induction motor of cap 0.5 HP. Note for Ser No 1 to 3 :- Cost of All Spares such as Bearing, Gland, Shaft sleeves, GM Bush, Rubber bush, impeller etc as per site, required to replaced if any shall be deemed to be included in the quoted rate and no any extra cost paid for spares separately.
M & L for Repairing/overhauling of spilt cage centrifugal pump set coupled with 1.5 HP motor by replacing of unserviceable parts like bearings, sleeves bushes, bearings housing shaft, gunmetal impeller etc. assembling the pump with new packing materials, nuts and bolts, washers and checking the alignment connecting up delivery, suction pipes and testing complete all as directed.
All as per item No 4 above but pump 0.5 HP. Note for Ser No 4 & 5 :- Cost of All Spares such as Bearing, Gland, Shaft sleeves, GM Bush, Rubber bush, impeller etc replaced if any shall be deemed to be included in the quoted rate and no any extra cost paid for spares separately.
M & L for Rewinding of centrifugal motor of capacity 7.5 HP, assembling and rewinding the motor with suitable size of copper enamelled winding wire and insulating materials, varnishing of pump set, bushes and any other parts require for proper functioning re-assembling, connecting and testing complete.
All as above Item No 6 but Mono block pump set 1.5 HP capacity
All as above Item No 6 but Mono block /submersible pump set 0.5 to 1.0 HP capacity
All as above Item No 6 but open well Submersible ump set 7.5 HP capacity
M&L for removing the submersible Non clog pump set of capacity 1.0 HP including column pipes and submersible cables complete from the existing open well of any depth by any suitable method i.e. either manual/ vehicle mounted motorized system and disconnecting the pump and motor to locate the faults in presence of Engr - in - charge and carry out repairs, including transporting's to Wksp and reassembling after repairs, complete including lowering after repairs and testing and commissioning all as specified and directed.
M&L for repair/overhauling of submersible pump set up to 1.0 HP capacity, and any stage by replacing bushes, impeller thrust bearings, strainer, nuts and bolts, washers, pump shaft remetalling, grinding, polishing, greasing complete reassembling the pump and testing, including painting with two coats of synthetic enamel paint after preparing the surface complete all as directed by the Engr-in-charge.
Servicing of star delta starter for pump set 0.5 HP by replacing over load relay of suitable range coil, spare kit for contactor, terminals, short pieces of copper wire duly crimped with bottle lugs etc and any other spares as required for proper functioning and monitoring of pump set all as specified and directed. Note:- Spares replaced if any shall be measured and paid separately as supply only under respective items.
All as per Sl item No 12 here-in-before but for 1.5 HP capacity
All as per Sl item No 12 here-in-before but for 7.5 HP capacity
Supply only spares for star delta starter for 0.5 HP to 7.5 HP Over load Relay range of (0.1 -1.5 Amps ) , max- 5A (as per sample) for 0.5 HP starter (Dol/Star delta) complete all as directed.
All as per item No 15 but Over load Relay range of (1.6 -2.5 Amps ) , max-10A (as per sample) for 1.5 HP starter (Dol/Star delta) complete all as directed.
All as per item No 15 but Over load Relay range (9.0-14.0 Amps ) for 7.5 HP starter(Dol/Star delta) complete all as directed.
All as per item No 15 but Power Contactors 415 volts ,50 cycles,3 phase, MNX-A2, 25 A to 50 A complete all as directed.
All as per item No 15 but MCB SP 6 A, 230 V.
All as per item No 15 but MCB TP 10 A TO 32 A, 415 V.
All as per item No 15 but Single phase preventer
All as per item No 15 but Start/ Stop button as per sample.
All as per item No 15 Indicator lamp Red/Yellow/Green/Blue colour as per site requirement.
All as per item No 15 but GIC timer as per site requirement.
All as per item No 15 but Toggle switch
All as per item No 15 but Digital type Voltage monitoring relay as per site requirement.
S & F MCCB 100 A, 415 V, 36 KA as per sample.
Dewatering/bailing out raw sewage and scratching the inner surface of the open RCC sewage collection tank of size 25.5 m³ including Coarse Bar Screen Chamber of size 1.6 m x 0.4 m x 0.6 m, and Oil and Grease Chamber of size 2.8 m x 0.75 m x1.7 m with the help of wire brush, steel Patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP and painted internally and externally with cement base paint and also writing name of the tank and date of cleaning complete all as specified and directed.
Cleaning and removing sludge from walls /floor of one Nos Equalization tank of 100 KLD STP with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and also including of M & L for painting to walls externally with super enamelled paint over a coat of red oxide primer and also writing name of the tank and date of cleaning complete all as specified and directed.
Cleaning, removing and bailing out stagnated sewage or sludge from walls/floor and any light particle with the help of wire brushes ,steel patti and emery paper from MBBR reactor steel tank for 100 KLD STP each and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it and also including of M & L for painting to walls externally with super enamelled paint over a coat of red oxide primer and also writing name of the tank and date of cleaning complete all as specified and directed.
All as per item No 30 but tube settler tank.
All as per item No 30 but intermediate tank.
All as per item No 30 Anoxic tank.
All as per item No 30 but Chlorine contact tank cum filter feed tank.
All as per item No 30 but underground sumps of 50,000 Ltrs capacity (Treated water tank) w and also including of M & L for painting of internally and externally with cement base paint and also writing name of the tank and date of cleaning complete all as specified and directed by Engr-in-charge. Note for item No 30 to 35 :-(a) The rate coated by the contractor is deemed to include writing letters/figures(Block,Roman,Italic or Indian) n. exc 20cm high. (Date of tank cleaned in format of (DD/MM/YY) and Capacity of Tank in Ltrs) with the help of stencils. (b) The rate quoted by contractor is for cleaning of tank once in six month one time cleaning only.
Cleaning of existing DMF by opening the lid and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 700 mm dia and also including of M & L for painting internally and externally with super enamelled paint over a coat of red oxide primer and also writing name of the filer and date of cleaning complete all as directed.
Cleaning of existing Activated Carbon Filter by opening the lid and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 700 mm dia and also including of M & L for painting internally and externally with super enamelled paint over a coat of red oxide primer and also writing name of the filer and date of cleaning complete all as directed.
Removing silt sludge and other raw material from kaccha drain with the help of JCB/Tractor and removing the sludge and depositing the same 50 mtr away from the starting edge of drain complete all as required at site .Note - All cost of T&P and other safety measures should be taken by the contractor with out any extra cost complete all as directed.
Taking out solid dry sewage waste from sludge drying beds of size 2.4 m x 2.4 m x1.2 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed.
S & F in repair/ top up MBBR media all as directed.
S & F in repair/ top up Tube Deck media all as directed.
S & F in repair/ top up Graded gravels all as directed.
S & F in repair/ top up Graded Pebbels all as directed.
S & F in repair/ top up Crushed gravels all as directed.
S & F in repair/ top up Coarse sand all as directed.
S & F in repair/ top up Fine sand/ Anthracite all as directed.
S & F in repair/ top up Activated carbon all as directed.
M&L for area cleaning under pump house premises as cutting/scraping of grass, unwanted trees, plant, levelling of earth surfaces, filling of digs etc complete all as directed. (Dimension of concerned area 60 m x 40m) .
Repair, maintenance, servicing to Chlorine dosing pump of any capacity by disconnecting both side inlet/outlet pipe line and electric connections including cleaning, greasing the internal parts, checking the serviceability of individual items, identification of the defective parts, replacing the Unserviceable spares, gaskets, gland etc. all as specified and directed. Note :- (1) Unserviceable parts replaced if any shall be measured & paid separately under respective items. (2) Quoted rate shall be included all minor parts which are required to make plant serviceable including following Spares(a to f). (a)PVC NRV set with valve (b)PVC adopter for suction and delivery without NRV (c)PVC strainer washer type heavy duty or Y type strainer for suction (d)Teflon gland square type 3mm (e)Chemical Oil seal with cap (f)Servicing will done every month.
Supply only PVC Dosing head assembly with Suction and delivery adopter with NRV for 25 LPH.
Supply only PVC NRV set with glass ball for suction and delivery adopter.
Supply only PVC adopter for suction and delivery without NRV.
Supply only PVC strainer washer type heavy duty or Y type strainer for suction.
Supply only Chemical Oil seal with cap
Supply only S.S. agitating rod with fan, PP coating
Supply only Plunger assembly without PVC dosing head 25 LPH
Supply only Heavy duty PVC NRV for delivery line.
Supply only Heavy duty FRP tank capacity 150 ltr including water level indicator and lid complete all as specified and directed.
M&L for star flex glow board with MS Frame including LED light 10 watts with internal electrical wiring lamp all as specified and directed by Engr-in-charge.
Supply only O-tolodine chlorine solution in packing of 2000 ml bottles for testing of chlorine contents in water.
Supply only chlorine testing kit complete all as specified and directed.
Testing of Raw/Treated sewage water sample parameter of STP through a NABL approved lab all as specified and directed.
S & F in repair replacement pressure gauge as per existing type model and complete all as specified.
S & F in repair Filter of blower of size 25 Cum/ Hr as per existing size complete all as specified.
Supply only air compressor oil Alfa ZN-320 for air blower complete all as directed.
Supply and fixing in replacement of steel reinforced V Belts of suitable size G-18 for Air Blower 7.5 HP electric motor complete all as directed.
M & L Framed work of grade Fe 410 W (grade -E- 250) as in doors or gates of angle or other section with gusset plates, rails, braces, support frame for pumps, ladders inside the sumps etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified.
M & L demolition of cement concrete in ground floors / paving's/Hard standing below/above ground level complete all as specified .
M & L PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in road cutting/floor cutting etc complete all as specified .
M & L , Cleaning / removing dirt's / oil from the surface of the motor and pumps / compressor/pipe line of any size & of any capacity at STP and Painting with one coat of super synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Supply only Alum (Aluminium Sulphate).
Supply only Calcium Hypochlorite granules disinfectant for water treatment having chlorine content (60-70) % all as specified.
Supply only Polyelectrolyte
Supply and fixing in repair Cast Iron butterfly valves of size 100 mm dia complete all as directed.
All as per item No 74 but of size 80 mm.
All as per item No 74 but of size 65 mm.
All as per item No 74 but of size 50 mm.
Supply and fixing in repair Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 25 mm dia complete all as directed.
All as per item No 78 but of size 32 mm.
All as per item No 78 but of size 40 mm.
Supply and fixing in repair Ball valves of size 25 mm dia complete all as directed.
All as per item No 81 but of size 50 mm.
Supply and fixing in repair Strainer for Suction of size 100 mm dia complete all as directed.
Supply and lay in repair M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 80 mm complete including welding as per site requirement all as directed.
All as per item No 84 but of size 65 mm.
All as per item No 84 but of size 50 mm.
All as per item No 84 but of size 40 mm.
All as per item No 84 but of size 32 mm.
All as per item No 84 but of size 25 mm.
M & L for galvanised steel Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5 mtr below ground level connecting to the galvanised GI wire 4 mm dia, by means nut bolt, nuts, check nuts and washer of the galvanised GI wire protected by provision of GI light grade pipe 15 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. Note : (i) GI Strip wire 4 mm dia up to 7.5 mtr from earth plate and protection pipe 15 mm dia shall deemed to be included in the quoted rate. (ii) Earth result shall be jointly recorded value shall be less than 2 ohm.
PLATINUM CONSTRUCTIONS
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .