| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.5 LAccepted-AOC SAINIK SOCIETY HITKARINI DENTAL COLLEGE DUMNA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹25.0 L+₹68,972.50 (2.83%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | L-3₹26.7 L+₹2.3 L (9.60%)Rejected-Finance 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L-3 | Rejected-Finance Being other than lowest. | |
| 4 | L-4₹26.7 L+₹2.4 L (9.68%)Rejected-Finance | L-4 | Rejected-Finance Being other than lowest. | |
| 5 | L-5₹26.8 L+₹2.4 L (10.0%)Rejected-Finance VILLAGE DEVRATHA NO 1 POST SHAHGANJ DIST AGRA U P | L-5 | Rejected-Finance Being other than lowest. |
Tender Value
₹34.3 L
EMD Value
₹68,600
Closing Date
26 Sept 2020, 6:00 pmClosed
GEAFADMAREAAGRA
GEAFADMAREAAGRA
REPAIR TO SECURITY FENCING WALL PERIMETER WALL AND ALLIED WORKS AT VARIOUS LOCATIONS UNDER AGE B R I OF GE AF ADM AREA AGRA
2020_MES_375039_1
8000-1824/E8
Open Tender
Civil Works
Item Rate
180 days
GEAFADMAREAAGRA
Class D Cat a ( i ) and for un enlisted firms docs as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹68,600
Yes
1 Oct 2020
5 Sept 2020
28 Sept 2020
5 Sept 2020
26 Sept 2020
14 Sept 2020
Amount
Dismantaling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
Dismantaling of fencing posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed surface on natural ground complete all as specified and directed.
Dismantaling fencing posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed surface on concrete/ brickwork masonary etc complete all as specified and directed.
Excavaton in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed.
M&L plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
M&L for bick work with subclass 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement motar 1: 4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster on fair faces of brickwork or concrete surface in CM 1:4 complete all as specified and directed.
M&L for prepration of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of chalk whiting primer complete all as specified and directed.
M&L for prepration of old decoreted surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 Gde E-165 complete complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new steel surfaces of any description over 10 cm in width or girth not otherwise described over one coat of red oxide primer including prepration of surfaces complete all as specified and directed.
S&F in repair razor wire fencing with 2.6 mm dia and 14 mm width, 0.5mm thick razor strip fixed with clamp to angle iron or swan neck angle or to existing angle iron as specified and directed.
Demolition of cement concrete unreinforced ground floor and paving n.exc 15 cm thick below or above GL complete all as specified and directed.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection finished the surface even and fair complete all as specified and directed.
M&L for cement concrete 100 mm thick type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in path etc finished the surface even and fair complete all as specified and directed.
Dismantaling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
M&L for machine made precast coloured inter locking tiles of any shape and size with grey cement and pigment confirming to IS-15658 of 2006 of 60 mm thick, M-35 grade laid, jointed after preperation of formation bed over & including 50 mm thick sand cusion complete all as specified and directed.
M&L for chequered cement concrete tiles of size 20 cm x 20 cm x 25 mm thick, with grey cement and no pigment, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F in repair concertina coil of 1050 mm dia in stress position not deep and aligned steel wire coated with CIR anti corrosive paints making diamond shape with the help of dove tail clips (18 SWG) fixed with barbed wir with angle iron, the concertina coil is to be fixed with barbed wire at points where coil touched the bottom points where coil touched the bottom barbed wire with the help of lug rings (24 SWG) complete all as specified and direccted.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, with excavated soil, including spreading levelling and ramming with watering in layers n exc 25 cm complete all as specified and directed.
Removing excavated soil n. exc 50.m and depositing where direccted at a level n exc 1.5 m above the starting point complete all as specified and directed.
M&L for precast cement concrete as in fencing posts/ struts, boundary pillars, type B-1, 1:2:4 (using 20 mm graded stone aggregate) complete all as specified and directed.
M&L in repairs for precast cement concrete louvres and jallies, 45 mm thick (measured solid), including all mouldings but excluding frame type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) set in 1:4 CM complete all as specified and directed.
M&L for mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. Fe 410 w (Gde 250 quality-A or Fe 290 (Gde F-165) complete all as specified and directed.
All as per BOQ sre item No. 31.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders.
M&L for cement concrete, type C-1, 1:3:6 ( using 20 mm graded stone aggregate) as in coping etc including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15 mm cement plaster 1: 1/2 :2 (1 cement : 1/2 coarse sand : 2 stone chipping 10 mm nominal size) in panels with groove all around as per approved pattern including providing grooves, scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified & directed.
deva engineers
Sethi Brothers
SAROJ CONSTRUCTIONS
M/s M S Sharma and Co.
Rakesh kumar
Mohd Gulab Hussain
Asha Construction
jmd engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .