Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L1 | Accepted-AOC Being a lowest bidder and reasonable. | |
| 2 | L2₹51.0 L+₹1.9 L (3.97%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹51.7 L+₹2.7 L (5.43%)Rejected-Finance 19 1A BOSE PUKAR ROAD KASBA GROUND FLOOR KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹52.0 L+₹3.0 L (6.06%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹52.1 L+₹3.1 L (6.29%)Rejected-Finance 6 NALAPUKUR LANE FLAT 2C SENHATI COLONY KOLKATA 700034 WEST BENGAL | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | PRABIR TRADERS L4 | KWALITY CONSTRUCTION L6 | Intime Commotrade Pvt Ltd L3 | ARJUN DAS VALECHA L8 | M A ENTERPRISES L1 | DGR CONSTRUCTION L7 | SK CONSTRUCTION SYNDICATE & ENGG CO L2 | Somani Builders L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of Asbestos cement corrugated, semi-corrugated sheet in roof covering complete all as specified and as directed. | 40 | Sqm | 45 ₹1,800 | 45 ₹1,800 | 42 ₹1,680 | 41 ₹1,640 | 32 ₹1,280 Lowest | 38 ₹1,520 | 40 ₹1,600 | 41 ₹1,640 |
| 2.00 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 40 | Sqm | 1,072 ₹42,880 | 1,069 ₹42,760 | 1,100 ₹44,000 | 1,110 ₹44,400 | 1,035 ₹41,400 Lowest | 1,104 ₹44,160 | 1,050 ₹42,000 | 1,090 ₹43,600 |
| 3.00 | M&L Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 10 | Sqm | 1,072 ₹10,720 | 1,069 ₹10,690 | 1,100 ₹11,000 | 1,110 ₹11,100 | 1,035 ₹10,350 Lowest | 1,105 ₹11,050 | 1,050 ₹10,500 | 1,090 ₹10,900 |
| 4.00 | Disentailing in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. | 50 | Rm | 28 ₹1,400 | 27 ₹1,350 | 25 ₹1,250 | 29 ₹1,450 | 20 ₹1,000 Lowest | 26 ₹1,300 | 30 ₹1,500 | 28 ₹1,400 |
| 5.00 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed. | 250 | Kg | 155 ₹38,750 | 162 ₹40,500 | 160 ₹40,000 | 115 ₹28,750 Lowest | 146 ₹36,500 | 157 ₹39,250 | 150 ₹37,500 | 150 ₹37,500 |
| 6.00 | M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and directed. | 50 | Sqm | 120 ₹6,000 | 126 ₹6,300 | 118 ₹5,900 | 128 ₹6,400 | 108 ₹5,400 Lowest | 119 ₹5,950 | 120 ₹6,000 | 123 ₹6,150 |
| 7.00 | M&L False ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 595 mm x 595 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed.
(NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board) | 40 | Sqm | 1,220 ₹48,800 | 1,234 ₹49,360 | 1,215 ₹48,600 | 1,238 ₹49,520 | 1,170 ₹46,800 Lowest | 1,241 ₹49,640 | 1,200 ₹48,000 | 1,232 ₹49,280 |
| 8.00 | Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. | 4 | Cum | 618 ₹2,472 | 625 ₹2,500 | 615 ₹2,460 | 628 ₹2,512 | 550 ₹2,200 Lowest | 614 ₹2,456 | 600 ₹2,400 | 622 ₹2,488 |
| 9.00 | M&L 25 mm thick cement concrete type B-0 , 1:2:4 ( 12.5 mm graded aggregate ) as in sub floors complete all as specified and directed by Engineer-in-Charge.. | 40 | Sqm | 255 ₹10,200 | 262 ₹10,480 | 248 ₹9,920 | 265 ₹10,600 | 243 ₹9,720 Lowest | 245 ₹9,800 | 250 ₹10,000 | 259 ₹10,360 |
| 10.00 | M&L 75 mm thick PCC 1:4:8 type C-2 (40 mm graded stone aggregate) as sub floor, finished even and fair complete all as specified and directed . | 40 | Sqm | 503 ₹20,120 | 509 ₹20,360 | 498 ₹19,920 | 515 ₹20,600 | 450 ₹18,000 Lowest | 513 ₹20,520 | 500 ₹20,000 | 506 ₹20,240 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
23 Jul 2025, 6:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR OF LT PANELS AND ALLIED UG CABLES OF DIFFERENT MD ACCNS AND ADDN / ALTN OF RATION STORE NEAR BLDG NO T-18 OF AOI AT OUTSIDE VIJAY DURG UNDER GE (FW) KOLKATA
2025_MES_718384_1
8408/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹88,000
7 Aug 2025
3 Jul 2025
24 Jul 2025
3 Jul 2025
23 Jul 2025
16 Jul 2025
Amount
Dismantling of Asbestos cement corrugated, semi-corrugated sheet in roof covering complete all as specified and as directed.
M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Disentailing in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and directed.
M&L False ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 595 mm x 595 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed. (NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board)
Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
M&L 25 mm thick cement concrete type B-0 , 1:2:4 ( 12.5 mm graded aggregate ) as in sub floors complete all as specified and directed by Engineer-in-Charge..
M&L 75 mm thick PCC 1:4:8 type C-2 (40 mm graded stone aggregate) as sub floor, finished even and fair complete all as specified and directed .
M&L Non Skid joint free coloured tiles 7-8mm thick area of each tiles exc 0.11 sqm but n.exc 0.18sqm (400X400X7-8mm),as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bedding in CM 1:6 complete all as specified and as directed.
M&L coloured glazed ceramic tiles in vertical surfaces 450X300X7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick cement plaster in CM 1:4 complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed.
S&F for 2nd class HW, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated.
S&F 35mm thick Factory made 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as directed.
S&F 100mm butt hinges stainless steel medium weight complete all as specified and as directed.
S&F aluminium handle, cast type anodised 150mm size all as directed.
Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed.
S&F steel window with side hung shutter including necessary hinges with steel handle and steel peg stay complete with glazing bars devotailed or welded all as directed.
Demolition of brick work built in cement mortar including all quoins arches pillars etc but excluding ashlars facing, dressed stone work and precast concrete articles complete all as directed.
M&L brick work with Fly ash bricks, straight or curved on plan exc 6m radius built in CM 1:6.complete all as specified and as directed.
Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as directed..
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick surface finished even and smooth without using extra cement complete all as specified and directed .
Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair all as specified.
M&L for providing on new plaster surfaces of walls applying two coats of distemper oil emulsion over one coat of primer and 1mm thick putty complete all as specified and directed.
M&L Preparing old decorated Surfaces of Walls and applying one coat of water proofing Acrylic emulsion paint ,complete all as specified and as directed.
M&L Preparing new plastered surfaces of Walls and applying two coats of water proofing Acrylic emulsion paint ,complete all as specified and as directed.
(E/M PORTION) Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing surfaces and Specifications.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in trenches sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
Laying in trenches bricks (Serviceable Bricks obtained from Item No. 9.00 here-in-after), for Cable Protection, complete all as specified and as directed.
Supply and lay pipe HPDE pipe of size 50 mm complete all as specified and directed by Engr-in-charge.
Supply and lay pipe HPDE pipe of size 100 mm complete all as specified and directed by Engr-in-charge.
Taking out of interlocking paver block, any shape or size and Re-laying the same after laying of LT cable of any size and also removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed. NOTE : Sand, if required for connection of cushioning level will be measured and paid separately.
Supply and Laying of Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench/pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- Note :- Necessary earth work to be measured and paid separately.
10 Sqmm to 50 Sqmm, 3.5 Core
70 Sqmm to 150 Sqmm, 3.5 Core
185 Sqmm to 240 Sqmm, 3.5 Core
240 Sqmm to 300 Sqmm, 3.5 Core
300 Sqmm to 400 Sqmm, 3.5 Core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 SQMM 4 Core . complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed.
M&L for Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 6.00 here-in-before) 1100 Volt grade, after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed of the following cross sectional area :-
10 Sqmm to 50 Sqmm, 3.5 Core
70 Sqmm to 150 Sqmm, 3.5 Core
185 Sqmm to 240 Sqmm, 3.5 Core
240 Sqmm to 300 Sqmm, 3.5 Core
300 Sqmm to 400 Sqmm, 3.5 Core
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1000mm x 1000 mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 400 Amps of adequate size for three phase and neutral system, fixed over and including 4 no's insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 No's Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 450mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories.-Location :- Near Masjid / Canteen CSD
(a) Manual change over switch 200 Amps, 4 pole, 415 volts, open execution type - 01 No.
(b) MCCB adjustable type with thermal-magnetic releases of capacity 200 A, 4P, 50 KA with spreader terminals - 02 Nos (I/C)
(c) MCCB adjustable type with thermal-magnetic releases of capacity 100 A 4P, 25 KA with spreader terminals - 03 Nos (O/G)
(d) MCCB adjustable type with thermal-magnetic releases of capacity 63 A 4P, 25 KA with spreader terminals - 01 No (O/G)
(e) MCB adjustable type with thermal-magnetic releases of capacity 63 A 4P, 10 KA with spreader terminals - 02 Nos (O/G)
(f) MCB adjustable type with thermal-magnetic releases of capacity 40 A 4P, 10 KA with spreader terminals - 02 Nos (O/G)
(g) Surge Protection Device 3P+N, 50 KA, 415 Volts, 50 Hz - 01 No.
(k) MCB SP 6 Amps, 10 KA - 3 Nos.
(l) LED type indication lamp R Y B - 01 set.
(m) Current Transformer Ratio 600/5A - 03 Nos
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1100 mm x 1100 mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 400 Amps of adequate size for three phase and neutral system, fixed over and including 4 no's insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 450mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories.- Location :- P-65
(a) Manual change over switch 200 Amps, 4 pole, 415 volts, open execution type - 01 No.
(b) MCCB adjustable type with thermal-magnetic releases of capacity 200 A, 4P, 50 KA with spreader terminals - 02 Nos(I/C)
(c) MCCB adjustable type with thermal-magnetic releases of capacity 125 A 4P, 25 KA with spreader terminals - 03 Nos(O/G)
(d) MCCB adjustable type with thermal-magnetic releases of capacity 63 A 4P, 25 KA with spreader terminals - 01 No (O/G)
(g) MCB SP 6 Amps, 10 KA - 3 Nos.
(h) LED type indication lamp R Y B - 01 set.
(i) Current Transformer Ratio 600/5A - 03 Nos
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1100 mm x 1100 mm x 500 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 400 Amps of adequate size for three phase and neutral system, fixed over and including 4 no's insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 450mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories.- Location :- Behind P-18.
(a) Manual change over switch 200 Amps, 4 pole, 415 volts, open execution type - 01 Nos.
(b) MCCB adjustable type with thermal-magnetic releases of capacity 200 A, 4P, 50 KA with spreader terminals - 02 Nos (I/C)
(c) MCCB adjustable type with thermal-magnetic releases of capacity 125 A 4P, 25 KA with spreader terminals - 03 No (O/G)
(d) MCCB adjustable type with thermal-magnetic releases of capacity 63 A 4P, 25 KA with spreader terminals - 01 No (O/G)
(g) MCB SP 6 Amps, 10 KA - 3 Nos.
(h) LED type indication lamp R Y B - 01 set.
(i) Current Transformer Ratio 200/5A - 03 Nos
Material and labour for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of size 25x4 mm as earthing lead by means of nuts, bolts and washers of galvanized iron and earth lead protected by galvanized iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanized (light grade) for watering, charcoal and salt in alternate layers including necessary excavation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I complete all as specified and directed. Note: (No extra payment will be for the earthing strip of size 25x4 mm)
S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
10 Sqmm to 16 Sqmm, 4 core
25 Sqmm to 50 sqmm 3.5/4 core
70 sqmm to 150 sqmm, 3.5 core
185 sqmm to 240 sqmm, 3.5 core
300 sqmm to 400 sqmm, 3.5 core
Demolition Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
M & L for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate for coping / encasing around of pole including necessary form work finished even and smooth without using extra cement all as specified and directed.
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting modular type switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage) (a) One light point or one fan point controlled by one switch
One 3/5 pin socket outlet, 5 Amp independent
One 3/5 pin socket outlet, 5 Amp on the same board with other switches
All as per item 63 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuity wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 63 above but using 4.0 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke (FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 4.0 sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed.
S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F Modular type White cover plate with frame 4 module complete all as specified and directed.
S & F Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S & F Ceiling rose, 3 terminal PVC insulated body complete all as specified and directed.
M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type all as directed.
All as per Srl. Item No. 79 above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 amps rated bus bar complete all as specified and directed.
Supply only MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply only MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S & F exhaust fan 300 mm sweep, heavy duty, 1400 RPM , AC single Phase 230 / 240 volts, metal body with louver shutters and connecting up with and including twin core twisted flexible copper conductor cable of suitable dia ,nut bolt and accessories, BEE 5 Star Rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
SK CONSTRUCTION SYNDICATE & ENGG CO (BID ID -3366951)
Intime Commotrade Pvt Ltd (BID ID -3367865)
PRABIR TRADERS (BID ID -3365025)
Somani Builders (BID ID -3364954)
KWALITY CONSTRUCTION (BID ID -3366209)
DGR CONSTRUCTION (BID ID -3365016)
ARJUN DAS VALECHA (BID ID -3367935)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .