Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹3.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹3.7 Cr+₹16.9 L (4.80%)Rejected-Finance | ₹3.7 Cr+₹16.9 L (4.80%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹3.8 Cr+₹29.3 L (8.33%)Rejected-Finance | ₹3.8 Cr+₹29.3 L (8.33%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹4.0 Cr+₹48.5 L (13.8%)Rejected-Finance | ₹4.0 Cr+₹48.5 L (13.8%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹4.3 Cr+₹76.7 L (21.8%)Rejected-Finance CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹4.3 Cr+₹76.7 L (21.8%) | L5 | Rejected-Finance Not lowest |
Tender Value
₹4.2 Cr
EMD Value
₹5.0 L
Closing Date
9 May 2022, 6:00 pmClosed
CE Shillong Zone
HQ CE Shillong Zone, Spread Eagle Falls, Shillong, Meghalaya
ADDN ALTN AND SPECIAL REPAIRS TO MD ACCN AT NARANGI MIL STN
2022_MES_513866_1
CESZ/NAR/ OF 2022-23
Open Tender
Civil Works
Item Rate
456 days
NARANGI
All as per NIT
2 documents required · 2 mandatory
₹2,000
GE Narangi
₹5.0 L
Yes
2 Jun 2022
15 Mar 2022
11 May 2022
15 Mar 2022
9 May 2022
27 Apr 2022
Amount
B/R Items
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises complete all as specified and directed.
Material & Labour for non skid coloured ceramic tiles 7 to 8mm thick, (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors set and jointed in cement slurry and pointed in white cement mixed with colour pigment to match existing surfaces over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
Material & Labour for Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface over and including 15mm thick screed bed cement mortar (1:6) complete all as specified and directed.
Material & Labour for Glazed ceramic tiles (Coloured) 450x350/350x250 and 300x200x7 mm thick on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including backing coat 10 mm thick cement mortar 1:4 complete all as specified and directed.
Material & Labour vitrified ceramic tiles (light shed) 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor including 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Material & Labour vitrified ceramic tiles (light shed) 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm (600x600mm),but as on vertical surfaces such as skirting/dado including 10mm thick backing coat in CM1:3 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings any gauge/thickness, as in valley gutter, ridge of roof, wall and cladding etc complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge/thickness, as in valley gutter, ridge of roof, wall and cladding etc
Supply & Fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, chajjas, fixed with self tapping screws as specified and directed.
Supply & Fix Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof covering/ cladding to wall, chajjas, valley gutter, fixed with self tapping screws as specified and as directed
Demolition of brickwork or stone/boulder masonry, built in lime/cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
Material & Labour for brick work with sub class "B" bricks (old size), straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specifed and directed.
Material & Labour for brick work with sub class "B" bricks(old size), straight or curved on plan to any radius in half brick thick walls built in built in CM 1:4 complete all as specifed and directed
Demolition of concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) & also removing the debris out side of Ministry of Defence land complete all as specifed and directed.
Material & Labour for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection/finish fair and smooth without using extra cement complete all as specifed and directed.
Material & Labour for 100mm thick Plain Cement Concrete 1:2:4 type B2 (using 40mm graded stone aggregate) as in path/paving/hard standing and finishing the surfaces even and smooth without using exra cement.
Material & Labour for 40 mm thick Plain Cement Concrete 1:2:4 type B-1 (using 20 mm graded aggregate) as in roof complete all as specified and directed.
Material & Labour for rendering 5mm thick in cement mortar 1:3 on fair faces of RCC concrete surfaces as in ceiling and including applying cement slurry in bottom of slab, chajjas, fin, facias etc.
Material & Labour for cleaning the top surface of concrete surface, including flushing and junction of parapets etc. and surfaces and APP base polymeric membrane minimum weighing 3kg/sqm and 3mm thick reinforced with polyester non-woven fabric (weight not less than 150gms/sqm) laid on bitumen 85/25 grade primer surface by forced application complete all as specified.
Preparation of new APP roof surfaces of any description and applying two coats of aluminium paint @ 0.1Litre /Sqm/Per Coat on APP surfaces exceeding 10cm width or girth all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Supply & Fix 4mm thick high pressure steam cured non asbestos cement designer board (E-board classic) GI frame work for EXPOSED GRID SYSTEM false ceiling of grid size 600mm x 600mm, GI powder coating at bottom and comprising of GI perimeter wall angle with two equal flanges of 25mm fixed to surrounding wall / partition using nylon sleeves and screws at 450mm centre to centre. Main Tee having 35mm wide flange and 25mm high web suspended from the soffit @ 1200mm c/c with level clip with wire of 4mm dia Cross Tee - 1200, 0.7mm thick having 35mm wide flange & 25mm high web inserted fixed in to the slots of main 'T' @ 600mm to form a grid of 1200mm x 600mm, Cross Tee - 600, 0.70mm thick having 35mm wide flange and 25mm high web inserted fixed into the slots of main 'T' @ 600mm to form a grid of 600mm x 600mm. Level clip with wire shall be suspended with soffit cleat which shall be fixed using Rawl Plug of 12.7mm dia @ 1200mm c/c in both direction all as shown and specified in SSR Part-II 2020 (Rates) complete all as specified and directed. (Note : Thickness of all the sections & spacing of section as specified on Sr page No. 184 to 186 of SSR Part-II (Rates))
Dismantling of stone slabs and tiles of and any description or thickness as in platform, shelves, floors etc laid, bedded and pointed in any mortar complete all as specified and directed.
Material & Labour for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Material & Labour Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrna Doogri/udaipur green over RCC slab including15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Material & Labour for machine cut kota stone slab flooring 20-25 mm thick over and including cement screed base 20 mm thick in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Material & Labour for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete and including 10mm thick rendering in CM 1:3 etc set and jointed in neat cement slurry complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from the frame)
Taking down chowkats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frame)
Supply & Fix Pressed steel frames for doors of size 125mmx60mmx1.25mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed.
Supply & Fix Pressed steel frames for doors of size 105mmx60mmx1.25mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed
Supply & Fix windows / ventilators for opening area not exceeding 1.50 sqm each (ECO-4000 Series ) fabricated from roll framed sections made of galvanized steel colour coated / powder coated (Base steel as per IS 513 "D" quality galvanized as per IS 277 with zinc coating of 120 gms/Sqm with total coated thickness of 0.06 mm, sections for frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 41mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly proof Mesh should be of 40mm x 20mm Section for Frame Glazed shutters and Mesh shutters should be cut to length mitred and jointed with polypropylene corner Brackets, Mullion Section should be joined with frame / Mullion using Mullion cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass, spoon section should be used around fly proof mesh to fix Mesh in Mesh shutter and including each Glazed shutter and Mesh shutter should be provided with Stainless Steel pivot hinges -1 set, Seccolor Handle & Seccolor Stay window frame should be fixed to brick / concrete masonary by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frame including Grill made of 10mm Sq. MS bars welded at 150mm centre-to-centre, 6mm x 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws and including with Primer coat of Epoxry Primer of 5-7 microns thick finish painted with Polyester paint of 12-16 microns thick or powder coated with polyester up to 50-60 microns thick complete all as specified and directed. Note : (1) Wire mesh and sheet Glass will be measured and paid separately under respective items of Schedule 'A'/BOQ. (2) Rest all as specified in drawing No CESZ/2018/TD/35 Sheet No 1/2 & 2/2.
Supply & Fix windows / ventilators for opening area exc 0.9 sqm but not exc 4 sqm each (ECO-4000 Series ) fabricated from roll framed sections made of galvanized steel colour coated / powder coated (Base steel as per IS 513 "D" quality galvanized as per IS 277 with zinc coating of 120 gms/Sqm with total coated thickness of 0.06 mm, sections for frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 41mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm Section for Frame Glazed shutters and Mesh shutters should be cut to length miter and jointed with polypropylene corner Brackets, Mullion Section should be joined with frame / Mullion using Mullion cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass, spoon section should be used around fly proof mesh to fix Mesh in Mesh shutter and including each Glazed shutter and Mesh shutter should be provided with Stainless Steel pivot hinges -1 set, Seccolor Handle & Seccolor Stay window frame should be fixed to brick / concrete masonary by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frame including Grill made of 10mm Sq. MS bars welded to at 150mm centre-to-centre, 6mm x 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws and including with Primer coat of Epoxry Primer of 5-7 microns thick finish painted with Polyester paint of 12-16 microns thick or powder coated with polyester up to 50-60 microns thick complete all as specified and directed. Note : (1) Wire mesh and sheet Glass will be measured and paid separately under respective items of Schedule 'A'/BOQ. (2) Rest all as specified in drawing No CESZ/2018/TD/35 Sheet No 1/2 & 2/2.
Material & Labour for mild steel conforming to Fe-290 Gde-E-165 small articles such as Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and directed.
Material & Labour for second class hard wood plain framed, factory made panelled door shutters 35 mm thick ( any number of panels ), with panels of timber flat on both sides ( feather edged), or of venerred particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkhats of second class hard wood complete all as specified and directed.
Material & Labour for 2nd class hard wood factory made glazed and skeleton door shutters of 35 mm thick, open rebated and prepared to receive glass, gauze, etc. divided in to squares,with plain, chamfered or rounded, mitred and rebated sash bars, any numbers; edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24(a); supplied and fitted to chowkhats.
Supply & Fix solid PVC door frame of size 50 x 47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube, in opening all as specified and directed.
Supply & Fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS Tube for top & bottom rails MS Frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded sealed to the stiles & rails with suitable PVC sheet beading & joined together with solvent cement supplied & fixed in the frame at site as per specifications and drawing.
Material & Labour for Cutting holes in brick walls built in CM exceeding half brick but not exceeding one brick for inserting holdfasts & making good dismantled portion in CM 1:3 or PCC 1:2:4 type B-1 as required and finishing to match the existing finish.
Material & Labour for preparation of new iron surfaces not exceeding 0.1 sqm each and applying tar or coal tar black paint to back of steel and iron works, such as gully gratings, holdfasts ends of post, back of chowkhats complete all as specified and directed.
Supply & Fix butt hinges, medium weight, cold rolled mild steel of 100 mm long all as specified and directed.
Supply & Fix aluminium, anodised, barrel tower bolts of extruded section, 150mm long all as specified and directed.
Supply & Fix aluminium handles, cast type anodised of 150 mm long all as specified and directed.
Supply & Fix aluminium alloy, anodised, sliding door bolt of 300 mm size with hasp, staple( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
Supply & Fix aluminium alloy, anodised, sliding door bolt of 250 mm size with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
Material & Labour for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide/zinc chrome primer complete all as specified and directed.
Material & Labour for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
Supply & Fix 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor all as specified and directed.
Supply & Fix 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Supply & Fix 2nd class hard wood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles not exceeding 200 cu. cm each complete all as specified and directed.
Material & Labour Plain Cement Concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in hold fast block, including form work complete all as specified and directed.
Material & labour for Plain Cement Concrete M-15(Nominal Mix) using 12.5 mm graded stone aggegate as in filling of hollow portion of pressed steel frames complete all as specified and directed.
Supply & Fix stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple complete all as specified and directed.
Supply & Fixed Sheet glass 4 mm thick ordinary quality and glazing with oil putty in sqaure not exceeding 0.50 sq. m in each pane complete all as specified and directed.
Supply & Fixed frosted glass 4 mm thick ordinary quality and glazing with oil putty in sqaure not exceeding 0.50 sq. m in each pane complete all as specified and directed.
Supply & Fix in repairs 1 mm thick stainless steel kitchen rack of size 31''x24''x10'' including fixing with rawl plug and screw all as directed
Supply & Fix in repairs 20 mm dia brass ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe and fixed complete all as specified and directed.
Supply & Fix in repairs Kitchen sinks with drainage board of overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm made of stainless steel 1mm thick (SS grade 304AISI 18/8) IS embosed (IS:13983) glossy finish kitchen sink with plugs, washers and wastes or brass ferrule of suitable size, PVC Pipe 90 cm long fixing with CP waste coupling 40 mm dia including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed.
Taking up or down existing 15 mm bore GI water tubing including all fittings complete all as specified and directed.
Taking up or down existing 20 mm bore GI water tubing including all fittings complete all as specified and directed.
Taking up or down existing 25 mm bore GI water tubing including all fittings complete all as specified and directed.
Supply & Fix GI tubing 15 mm bore medium grade with all fittings like Tee, bend, elbow etc, fixed to walls or ceilings or laying in floors complete all as specified and directed.
Supply & Fix GI tubing 20 mm bore medium grade with all fittings like Tee, bend, elbow etc, fixed to walls or ceilings or laying in floors complete all as specified and directed.
Supply & Fix GI tubing 25 mm bore medium grade with all fittings like Tee, bend, elbow etc, fixed to walls or ceilings or laying in floors complete all as specified and directed.
Supply & Fix in repairs fancy type bib taps, chromium plated cast copper alloy 15mm bore with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
Supply & Fix in repairs PVC valveless, syphonic action type, low level flushing cistern 10 Ltr capacity with complete fittings, flush pipe & float valves, handle including brackets etc complete.
Supply & Fix in repairs vitreous china wash basin, white, flat back, of size 550 x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
Supply & Fix in repairs vitreous china wash down water closet pan (Pedestal pattern) white including 'P' or 'S' trap, PVC seat cover and making good the disturbed surface to match with the existing complete all as specified and as directed.
Supply & Fix in repair 15 mm bore dia pillar taps, cast copper alloy , with capstan heads, chromium plated, screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and fly nuts, etc complete all as specified and directed.
Supply & Fix in repair 32mm dia waste pipe coupling, brass, chromium plated for glazed ware, basins, etc. with long screwed shanks and fly -nuts, flange end bedded in red lead cement and other end fixed all as specified and as directed
Supply & Fix in repair PVC connections pipe 15mm size with PTMT nuts of length 450mm complete all as specified and as directed
Supply & Fix in repair 15 mm dia stop valves, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends complete all as specified and as directed.
Supply & Fix in repair 32mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floor etc complete all as specified and as directed
Supply & Fix in repairs stainless steel Soap dish, fixed with chromium plated brass screws complete all as specified and as directed
Supply & Fix in repairs stainless steel tubular towel rail 20mm dia, 600mm long including necessary aluminium brackets complete all as specified and as directed
Supply & Fix in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding all as specified and directed.
Supply & Fix in repairs chromium plated brass angle valve suitable for 15mm bore pipe, complete all as specified.
Supply & Fix in repairs Chromium plated shower roses with or without swivel joints, 125 mm size, including fixing to steel pipe or union complete all as specified and as directed
Supply & Fix in repair PVC bathroom mirror cabinet with 4 mm thick looking glass mirror of overall size 560x410x 355mm of approved colour and pattern all as specified and directed
Dismantling PVC/cement water tank not exceeding 500 ltrs capacity complete all as specified and as directed.
Supply & Fix rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position of 500 litres capacity confirming to IS specification complete all as specified and as directed
Taking down cement plaster/cement lime plaster on brick walls etc, including raking out joints, hacking for key, scrubbing down with water etc.
Material & Labour for rendering 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
Material & Labour for 15mm thick plaster in cement mortar 1:4 on fair faces of brick or concrete surfaces in two layers, 1st layer of 10mm thick and 5mm thick 2nd layer mixed with water proofing compound @ 3% by weight of cement finishing the surfaces even and smooth without using extra cement complete. Note: i) Integral water proofing compound shall be measured and paid separately.
Material & Labour for rendering 5mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces as in ceiling finished even and smooth without using extra cement.
Supply only approved integral water proofing compound.
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down including applying a layer of 1 mm thick wall care putty for making the surface even & smooth and applying two coats of oil bound distemper over a coat of Alkali resistant primer including necessary cleaning splashes of paints from window panes and floor etc complete all as specified.
Material & Labour for preparation of new plaster surfaces of wall and applying 2 coats of oil emulsion distemper over 1mm thick wall care putty on wall and a coat of alkali resistant priming paint all as specified and directed.
Material & Labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash including preparation complete all as specified and as directed.
Material & Labour for preparation of old decorated surfaces of walls including cornices, pilasters etc & applying one coat of white wash on walls including necessary cleaning splashes of white wash from window panes and floor etc complete.
Material & Labour for preparation of old decorated surfaces of ceiling & applying one coat of white wash including necessary cleaning splashes of white wash from window panes and floor etc complete.
Material & Labour for Preparation of new plastered surface of wall etc and applying two coat of exterior emulsion weather coat paint over a coat of weather coat exterior primer over 1mm thick wall putty complete all as specified and directed.
Material & Labour for complete scrapping of existing treatment of wall, preparation of old surfaces of wall etc and applying two coat of exterior emulsion weather coat paint over a coat of weather coat exterior primer over 1mm thick wall putty complete all as specified and directed.
Dismantling structural steel work, wrought iron or mild steel work including door, gates, of any description not otherwise provided for all as specified and directed.
Supply & Fix mild steel as in framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 fixed with angle cleats or other connecting plates
Supply & Fix Welded mild steel wire fabric not exceeding 4 kg per sqm supplied and fixed complete to wood or steel members complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with screws with and including aluminium framed work in partition complete all as specified and directed
Material & Labour for 19 mm thick block board, grade 2 quality, interior grade, decorative type with decorative lamination on both faces, fixed with screws/nails to timber frame work all as specified and directed.
Material & Labour 2nd class hard wood Plain fillets square or rectangular or trangular in section, clean sawn, secured with nails, screw or brads sectional area not exceeding 3 sqcm all as specified and as directed.
Material & Labour 2nd class hard wood Plain fillets square or rectangular or trangular in section, clean sawn, secured with nails, screw or brads sectional area exceeding 6 sqcm & not exceeding 13 sqcm all as specified and as directed.
Supply & Fix 30mm (Width of flaps (when open) in mm) Continuous (piano) hinges, mild steel, bright finish or electrogalvanised all as specified
Supply & Fix 100mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
Supply & Fix Standard quality Magnetic catcher for cup board shutter all as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
Supply & Fix in repair 110 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
Supply & Fix in repair 75 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
Supply & Fix in repair 110 mm dia bore PVC (SWR) bends any radius complete all as specified and directed
Supply & Fix in repair 75 mm dia bore PVC (SWR) bends any radius complete all as specified and directed
Supply & Fix in repair 110 PVC mm (SWR) branch piece, single (single Y) equal or unequal with oval access door complete all as specified and directed
Supply & Fix in repair 75 mm PVC (SWR) branch piece, single (single Y) equal or unequal with oval access door complete all as specified and directed
Supply & Fix in repair 110 mm PVC (SWR) junction single, (Single T) equal or unequal with oval access door complete all as specified and directed
Supply & Fix in repair 75 mm PVC (SWR) junction single, (Single T) equal or unequal with oval access door complete all as specified and directed
Supply & Fix in repair 110 mm PVC (SWR) couplers complete all as specified and directed
Supply & Fix in repair 75 mm PVC (SWR) couplers complete all as specified and directed
Supply & Fix in repair 110 mm PVC (SWR) reducers complete all as specified and directed
Supply & Fix in repair 75 mm PVC (SWR) reducers complete all as specified and directed
Supply & Fix in repair 110 mm PVC (SWR) vent cowl complete all as specified and directed
Supply & Fix in repair 75 mm PVC (SWR) vent cowl complete all as specified and directed
Supply & Fix stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm/100mm dia bore of pipe.
Supply & Fix in repairs Stainless Steel grating 100 mm dia setting and jointing with solvent cement complete all as specified and directed
Supply & Fix in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed
Supply & Fix in repair Cast iron Nahani trap 100 mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
Supply & Fix in repair Cast iron Nahani trap 75 mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
Demolition of concrete in ground floors and pavings exceeding 15 cm thickness (below or above ground level) & also removing the debris to the out side of Ministry of Defence land complete all as specified and directed.
Material & Labour for 50 mm dia and 350 mm long medium grade GI pipe spouts with wire gauge on inside mouth to be fixed before water proofing treatment of sunken slabs by cleaning RCC slab surface floors and walls by wire brush and rendering 6 mm thick in CM 1:4 mixed with integral Water Proofing Compound on uneven surface to make it even. Fill with water and check for dampness and seepage, all junctions points of side walls where CI/GI pipe are passing shall be sealed with epoxy mortar. Apply two coats of polymer modified cementious water proofing coating of minimum thickness of 1 mm each layer as per manufacturers instructions on floor & walls (upto 100 mm above Floor Finished Level) and spray coarse sand on surface when the second layer is still sticky. Apply 20 mm thick plaster in CM 1:4 mixed with integral Water Proofing Compound of approved make on floors and walls including rounding of corners and junctions stoping towards spouts. All pipes laid in sunken portions shall be covered with 50 mm thick PCC 1:3:6 all around after painting with anti corrosive black japan paint on GI/CI pipes. Test the water proofed area by filling water at least 72 hours and tested for leakage/seepage for the entire satisfaction of GE. After above said treatment apply two coats of hot blown bitumen @ 1.5 Kg /Sqm for each coat and laying 50 micron black polythene film in floors complete all as specified and directed. (Note : If leakage/Seepage occured after filling water at least 72 hours, the above said treatment will be re-done completely without any extra cost.)
Material & Labour for plain cement concrete 1:3:6 type C-2, (40 mm graded stone agg) as in foundation filling or sunken floors etc all as specified and directed.
Demolition and breaking up drain pipe SGSW/CI/PVC pipes of 110mm dia from trenches including cement concrete haunching etc complete all as directed.
Supply & Fix 110mm dia PVC (SWR) pipes, pressure rate having 6 Kgf single socketed in any length with rubber ring joints and laid in trenches as in waste/soil pipe complete all as specified and as directed.
Material & Labour for plain cement concrete type D2 1:4:8 (40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Material & Labour cement concrete 1:3:6 type C-2, using 40mm graded stone aggregate as in bed to drain pipes of dia 150 mm including packing under & haunching against the sides of pipes after they are laid & tested incomplete all as specified and directed.
Supply & Fix in repairs fancy type drapery rods, powder coated aluminium of 20-25 mm size with brackets, knobs/roller required for fitting etc all as specified and as directed.
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similar suspended work complete all as specified.
Material & Labour for Reinforced Cement Concrete 1:1.5:3 type A-1, using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material & Labour for Reinforced Cement Concrete 1:1.5:3 type A-1, using 20mm graded stone aggregate as in beams, cantilevers, lintel beam, lintels over 1.5 m span complete all as specified and directed.
Material & Labour for Reinforced Cement Concrete 1:1.5:3 type A-1, using 20mm graded stone aggregate as in slabs supported on walls, beams and columns, in floors, roofs, parapet, landings, balconies, complete all as specified and directed.
Material & Labour for Reinforced Cement Concrete 1:1.5:3 type A-1, using 20mm graded stone aggregate as in Chajjas complete all as specified and directed.
Use and waste of formwork, fair finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of Formwork, fair finished surface to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
Use and waste of Formwork, fair finished surfaces to sides & soffits of floor or roof beams, beam haunchings, girders, bresumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams etc. complete all as specified and directed.
Use and waste of Formwork, fair finished surfaces to soffits of suspended slabs, floor slabs, landings and similar work; not exceeding 200 mm thick ( Horizontal or sloping) complete all as specified and directed.
Material & Labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for colums, hooking ends, and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Material & Labour for mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia omplete all as specified and directed
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed.
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including paint touch up to match with the existing surface complete all as specified and directed.
Taking down ceiling/exhaust /wall fan including connection wires carefully, removal to store in safe costody and refixing the same in original position after repairing (rewinding if required), painting with synthetic enamel paint by spraying including filling cavity complete all as specified and directed.
Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for one light/fan/bell point controlled by one, one way switch.
Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for one light point controlled by two, two way switch.
Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for one 3 pin socket outlet 5 Amps on the same board with other switch.
Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for one 3 pin socket outlet 5 Amps on the independant board.
Point wiring with 2.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 2.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for one 6 pin socket outlet 15 Amps on the independant board.
Supply & Fix Switch piano, flush type single pole, one way 6 Amp, complete all as specified and directed.
Supply & Fix Switch, two way 6 Amp, 230 volt complete all as specified and directed.
Supply & Fix socket outlet 2 in 1, 3 Pin 5 Amp, flush type complete all as specified and directed.
Supply & Fix switch socket combination 2 in 1, 5 Amp, flush type complete all as specified and directed.
Supply & Fix switch socket combination 5 in 1, 5/16 Amp, flush type complete all as specified and directed.
Supply & Fix ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed.
Supply & Fix Lamp holder, PVC/ Polycarbonate type with back plate complete all as specified and directed.
Supply & Fix electronic stepped type electronic fan regulator, two module size flush type on the existing phenolic laminated sheet complete all as specified and directed.
Point wiring for modular fitting with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box made out of 1.6mm thick mild steel for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for one light/fan/bell point controlled by one, one way switch.
Point wiring for modular fitting with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box made out of 1.6mm thick mild steel for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for 3 pin socket outlet 5 Amps on the same board with other switch.
Point wiring for modular fitting with 1.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box made out of 1.6mm thick mild steel for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for 3 pin socket outlet 5 Amps on independant board.
Point wiring for modular fitting with 2.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box made out of 1.6mm thick mild steel for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 2.5 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for 6 pin socket outlet 15 Amps on independant board.
Point wiring for modular fitting with 4 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLS copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (medium grade) and conduit accessories and sunk type pressed steel box made out of 1.6mm thick mild steel for mounting of fitting and 3 mm thick plastic laminated sheet top covers alongwith continuous earth wire 4 Sq mm PVC insulated and un-sheathed single core FRLS cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly complete for North west modular outlet, tiny trip C 25, 2 pole MCB, 240V 50 Hz single phase motor starter.
Supply & Fix modular bell push switch, one module, 6 Amp, ISI marked complete all as specified and directed.
Supply & Fix electric bell ding dong AC 230 volts single phase complete all as specified and directed.
Supply & Fix modular switch, one module, one way 6 Amp, ISI marked complete all as specified and directed.
Supply & Fix Modular socket 6 Amp, 2/3 pin combined, 2 module, 240 volts, ISI marked complete all as specified and as directed.
Supply & Fix Modular Switch socket outlet 3 pin 6 Amp flush type, 3 module, 240 volts, ISI marked complete all as specified and as directed.
Supply & Fix Modular Switch socket outlet 5 pin 6/16 Amp flush type, 3 module, 240 volts, ISI marked complete all as specified and as directed.
Supply & Fix white cover plate with frame (both inner plate & outer plate cover) modular for 1 module.
Supply & Fix white cover plate with frame (both inner plate & outer plate cover) modular for 3 module.
Supply & Fix white cover plate with frame (both inner plate & outer plate cover) modular for 12 module.
Supply & Fix modular ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/square block complete all as specified and directed.
Supply & Fix for modular Lamp holder, PVC/ Polycarbonate type with back plate complete all as specified and directed.
Supply & Fix modular electronic stepped type electronic fan regulator, two module size flush type complete all as specified and directed.
Supply & Fix mirror light fitting 1x 10 W luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Jaguar Cat No. JNL-BR9-CXLNDSIE-14 or as equivalent in specified make list.
Supply & Fix North west modular outlet, tiny trip C 25, 2 pole MCB, 240V 50 Hz single phase motor starter current range from 11 Amp to 18 Amp 240 V 50 Hz AC including top complete all as specified and directed.
Supply & Fix light fitting 1 x 9W/1x 10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & Fix in repairs LED box type light fitting pre-wired including LED tube 1 x 18 W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable of suitable size & fix on 2 No. PVC block complete all as specified and directed.
Supply & Fix in repairs LED box type light fitting pre-wired including LED tube 1 x 10 W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable of suitable size & fix on 2 No. PVC block complete all as specified and directed.
Supply & Fix repairs wall decorative fixture in durable plastic body & designer mesh in gold finish suitable for 9W LED lamp of B-22, including lamp of 9 W, complete all as specified and directed. Make: Havelles Cat No. LHFOECE1TZ1B014 or as equivalent in specified makes list
Supply and fix electric water heater, storage type steel body with copper dry powder ferro glass technology inner tank and heating element heavy duty seamless incoloy 800 glass lined upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
Supply and fix heavy duty exhaust fan, steel body AC single Phase. 230V of size 300m sweep with 1400 RPM blades, and frame and louvers including anchor bolt of suitable size for fixing arrangement and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 230m sweep with blades, and frame and louvers including anchor bolt of suitable size for fixing arrangement and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.
Supply & Fix ceiling fan 1200 mm sweep, 5 star rating high speed with brushless direct current motor(BLDC), including suitable size of fan hook and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.
Dismantling old electric kWH meters carefully by disconnecting all electric connection and re-fixing serviciable meter after necessary repair of electric energy kWH meter single phase 05 to 60 Amps, including making connection of incomming and outgoing wiring circuits and submission of kWH reading details of old unserviceable taken down meter complete all as specified and directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed
Material & Labour for fabrication of angle iron frame of size 18 inch x 24 inch using 30 x 30x 5mm angle iron firmly grouted in wall surface using support and fixing 6mm thick flameproof Hylem sheet of size 19 inch x 25 inch on top for mounting 4 Nos electric energy meters single phase, including making good to damaged surface of wall and making necessary electrical connection using 6.0 Sqmm single core copper multistranded cable through PVC conduit from MCB DB box to incomming of meter and outgoing connection of submain circuit wiring complete all as specified and directed. Note: Quoted rate includes making all incoming and outgoing electrical connections using PVC insulated multistranded copper conductor wire of size 6.0 sqmm through PVC conduit pipe in gray color from MCB DB to electric meters.
Supply & Fix factory made MCB Distribution board double door type TPN 4 way, sheet steel, powder coated, with 200 Amp rated bus bar neutral link & earth bar etc. for fixing MCBs of various rating capacity and grouted in wall with PCC (1:2:4) type B-1 using 20mm graded stone aggregate including taking down old unserviceable MCB DBs complete all as specified and as directed.
Supply & Fix factory made MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with 200 Amp rated bus bar neutral link & earth bar etc. for fixing MCBs of various rating capacity and grouted in wall with PCC (1:2:4) type B-1 using 20mm graded stone aggregate including taking down old unserviceable MCB DBs complete all as specified and as directed.
Supply & Fix MCB SP 6-32 Amps 'C' series, 240 volts, 50 Hz, 10 kA suitable for fixing in MCB DB including taking down old unserviceable MCB complete all as specified and as directed.
Supply & Fix MCB SPN 32 Amps 'C' series, 240 volts, 50 Hz, 10 kA suitable for fixing in MCB DB including taking down old unserviceable MCB complete all as specified and as directed.
Supply & Fix MCB TPN 40 to 100 Amps 'C' series, 240 volts, 50 Hz, 10 kA suitable for fixing in MCB DB including taking down old unserviceable MCB complete all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and directed by Engr-in-Charge. Note :- Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately.
Sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 6.0 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 6.0 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.
Supply, Fixing & testing of LED street light fitting (Building Security light) of 48 Watt, driver and made of pressure die-cast aluminium housing with epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual lenses IP 66 & high power LED’s as light source with LED fitting system lumen efficiency not less than 100 Lumen per watt and electronic driver with efficiency > 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 4 KV ensuring longer life (THD <10%, PF shall be > 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than two years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture. Make : Cat No. ENDURAPEARNEOSL48 WLED757SASYTOPC of Havelles or as equivalent in specified make list
Material & Labour for building security light fitting bracket made out of 40 mm dia (or size as per manufacturers recommendation) medium grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 2 mtr long complete with MS flat iron clamp (clamps shall be 40 x 6 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.
Dismantlling geyser of any type carefully by disconnecting all electric connection and re-fixing the same after necessary repair of geyser, painting with synthetic enamel paint by spraying including all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed.
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm, 4 core laid in trenches/pipes/ducts/ trenches under road complete all as specified and directed.
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq mm, 4 core laid in trenches/pipes/ducts/ trenches under road complete all as specified and directed.
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq mm, 3.5 core laid in trenches/pipes/ducts/ trenches under road complete all as specified and directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge. Note :- Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately.
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof, IP-54 feeder pillar box made out of 3.15 mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm, powder coated over one coat of red oxide primer suitably grouted in PCC (1:2:4) using 20 mm graded stone aggregate of size 700mm x 300mm x 600mm on adjecent pair of leg and net cementing the same. The feeder pillar box shall duly painted with two coats of synthetic enamel paint over a red oxide primer (internally and externally) on the surface. Including bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The panel board shall comprise of following items & all as specified in SSR Part-I clause No 19.21. (A) INCOMING:- (i) 4 strip aluminium bus bar (covered with colour coded insulated PVC sleeves), 200 Amp capacity of suitable length including connection etc. complete - 01 Set, (ii) Phase indicator lamp R-Y-B, neon type (Set of Three)- 01 Set (iii) MCCB 125 Amps, 4 pole, 415 volt, 16 KA - 01 Nos (iv) Digital voltmeter, three phase, Cl-1, 0-500V flush mounting - 01 No (v) Digital ammeter, three phase, Cl-1, 0-100A flush mounting 96 x 96 mm site programmable including CT - 01 No (B) OUTGOING:- (i) MCB 4 pole 40 amps, C curve, breaking capacity 10kA, 415 volt - 05 No (1 spare) Note: All cable in the feeder pillar box should be properly thimbled as specified and directed.
Supply and laying Galvanised steel tubing 25 mm bore, light grade fixed in electrical pole, walls or laid in floors including flat iron clamps of suitable size, with nuts, bolts, etc. for protection of electrical connection cable complete all as specified and as directed.
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil.
Supply & Fix Modular Switch, two way 6 Amp, 230 volt complete all as specified and directed.
Cutting/digging of existing surface of cement concrete/bituminous road of size not less than 45cm in width and 20cm deep for laying of cable and making good to disturbed surface by providing PCC or any other materials as per existing surfaces after laying cable including returning filling complete all as specified and directed.
Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Material & Labour for laying brick sub class 'B' (locally available best quality) burnt bricks for cable protection laid in dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and as directed.
Schedule of Credit
M/s T. S. POWER CO.
Pusphas Construction Pvt Ltd
M/s AGAM CONSTRUCTION
M/S ALLIED CONSTRUCTION
M P KHAITAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .