Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-Finance | ₹25.7 L | L1 | Accepted-Finance low |
| 2 | L2₹27.5 LAccepted-Finance | ₹27.5 L | L2 | Accepted-Finance High |
| Sl No | Description | Qty | Unit | M/s Kamal Dev Sharma L2 | SUSHANT PURI L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres | 98 | Cum | 250 ₹24,500 | 210 ₹20,580 |
| 2.00 | Cement concrete 1:4:8 with stone ballast or 40mm shingle mixing by mechanical means using concrete mixer volumetric type | 4.7 | Cum | 5,000 ₹23,500 | 4,500 ₹21,150 |
| 3.00 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth | 19.47 | Cum | 6,500 ₹1.3 L | 7,800 ₹1.5 L |
| 4.00 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. | 34.94 | Cum | 8,000 ₹2.8 L | 8,200 ₹2.9 L |
| 5.00 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 37.02 | Sq.Mtr | 250 ₹9,255 | 250 ₹9,255 |
| 6.00 | Centering and shuttering for columns (circular or curved in plain) | 9.47 | Sq.Mtr | 570 ₹5,397.90 | 590 ₹5,587.30 |
| 7.00 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. | 37.68 | Sq.Mtr | 435 ₹16,390.80 | 490 ₹18,463.20 |
| 8.00 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc | 58.09 | Sq.Mtr | 600 ₹34,854 | 650 ₹37,758.50 |
| 9.00 | Centring and shuttering for R.C.C. domes | 28.26 | Sq.Mtr | 2,500 ₹70,650 | 2,100 ₹59,346 |
| 10.00 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position | 25.4 | qtl | 15,000 ₹3.8 L | 11,000 ₹2.8 L |
Tender Value
₹22.7 L
EMD Value
₹45,441
Closing Date
3 Mar 2026, 12:00 pmClosed
Executive Engineer
Executive Engineer ,Ropar Canal and Ground Water Division WRD Punjab
Estimate for Construction of Overhead Reservior In Rampur Jhajjar Lift Irrigation Scheme in Changer Area of Shri Anandpur Sahib
2026_WR_161379_1
65/22A/2025-26
Open Tender
Civil Works
180 days
village rampur jhajjar near Shri Anandpur Sahib
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹45,441
17 Apr 2026
20 Feb 2026
3 Mar 2026
20 Feb 2026
3 Mar 2026
20 Feb 2026
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
Cement concrete 1:4:8 with stone ballast or 40mm shingle mixing by mechanical means using concrete mixer volumetric type
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for columns (circular or curved in plain)
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc
Centring and shuttering for R.C.C. domes
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shade on wood work,metal licor plastered,concrete surface to give an even shade.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. ;323.9 mm o/d thickness 5.6 mm including epoxy coating
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts c) 150 mm internal Diameter
Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore.u) 300 mm Steel Strainer (slot size0.15mm) 8.00 mm thickness
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge). a)Class PN-1 as per IS f) 300mm i/d Sluice Valves flanged
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge). a)Class PN-1 as per IS f) 150mm i/d Sluice Valves flanged
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). Earthing with 8 S.W.G. (4 mmdia.) G.I.wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14 Metre in length)
Water proofing of wet areas (Concrete/Masonary Surface) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating(DR.FIXITFASTFLEX/Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joint stop revents water leakage.The scope of work also includes surface prepration and cleaning,washing and removing dust,dirt and loose particles from concrete/masonary surface complete in all respects.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, including the cost of diversion for traffic, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Any Other Items
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_327167.pdf
techsummary_327167.pdf
finance_327167.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
ccess.pdf
Tender Documents • 0.14 MB
gstletter.pdf
Tender Documents • 0.32 MB
BOQ_327167.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid