| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | ₹16.7 L | L1 | Accepted-AOC Accept |
| 2 | L2₹17.0 L+₹26,387 (1.58%)Rejected-AOC | ₹17.0 L+₹26,387 (1.58%) | L2 | Rejected-AOC Reject |
| Sl No | Description | Qty | Unit | NPK Associates L1 | NMS ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling the existing damaged RCC slabusing Electric Power Breaker as per deparmental officer etc., Complete | 9 | hrs | 637 ₹5,733 Lowest | 650 ₹5,850 |
| 2.00 | Earth work excavation in all kinds of soil including sand, silt, wet sand under water, black cotton, stiff black cotton, clay, hard stiff clay, hard red earth, murram, stoney earth, gravel and shales etc. excepting all kinds of rock and boulders exceeding 0.014 c.u.m, in volume including rough dressing and dumping the ecavated materials away from work site manually within 50m initial lead and 2m initial lift as per the direction of Engineer-incharge. departmental officers etc complete | 10 | m3 | 220 ₹2,200 Lowest | 225 ₹2,250 |
| 3.00 | Cement concrete 1:4:8 (one cement, four sand and eight aggregate) using 40mm hardbroken granite stone jelly for foundationincluding dewatering if found necessary andlaid in layers of not more than 15 cm thickand compacted etc.,complete | 10 | m3 | 5,962 ₹59,620 Lowest | 6,100 ₹61,000 |
| 4.00 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 1OOCFT | 2 | m3 | 7,727 ₹15,454 Lowest | 7,800 ₹15,600 |
| 5.00 | Supplying and erecting SHUTTTERING including necessary supports for plane surfaces such as Drain walls etc, using mild steel sheets of size 90cm X 60Cm and BG 10 stiffened with welded mild steel angles for boarding supported by Casuarinas props at suitable intervals etc., complete complying with standard specification and as directed. | 10 | m2 | 868 ₹8,680 Lowest | 900 ₹9,000 |
| 6.00 | Flooring with Ellis Pattern using 6mm Chips(No Sand to be Used) | 35 | m2 | 531 ₹18,585 Lowest | 550 ₹19,250 |
| 7.00 | Supplying and fixing Roofing with PPGL Steet iron corrugated sheet 0.47 mm thick including necessary bolt,nuts and bitumen washed etc., completed - 10 m2 | 16 | m2 | 1,163 ₹18,608 Lowest | 1,200 ₹19,200 |
| 8.00 | Supplying and fixing Supplying of Laser Cutting Sheet For Grill and Gate and Ornamental Grill including necessary bolt,nuts and bitumen washed etc., complete complying with standard specification. | 60 | m2 | 5,000 ₹3,00,000 Lowest | 5,100 ₹3,06,000 |
| 9.00 | Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 4042Kg/M3, Thermal conductivity (KValue) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. | 105 | m2m2 | 2,386 ₹2,50,530 Lowest | 2,400 ₹2,52,000 |
| 10.00 | Design,Supply and Erection Tensile Membrances Structure of high tensile strength, primary and secondary steel ,Jhardware and accessories, including the fabrication of steel structure made out of MS structural steel tubular section of high yield strength as per relevant IS codes. The tensile membrane roof covershall be of PVC coated polyester composite membrane of approved make and quality including membrane cutting seaming and HF welding as per manufacturer standards. The membrane shall be fixed to MS structural members with necessary SS plates, lugs, clamping plates as required. The membrane shall be stretched and tensioned as per the design approved. The Membrane shall be flame resistant, fungicide finish, high tear out force and continued tear out force,well wieldable, good UV resistance, high water pressure resistance and very low maintenance. This work to be executed with specialized agency. etc complete as per the direction of the Departmental officers. | 100 | m2 | 5,600 ₹5,60,000 Lowest | 5,650 ₹5,65,000 |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
5 Mar 2026, 3:00 pmClosed
The commissoner, coimbatore
Coimbatore Corporation, Main Office, Big bazaar street, Town hall, Coimbatore-1
Improvement works to Omni Bus Stand at Sathy Road in Ward No 48 Central Zone.
2026_MAWS_669053_9
e29/2026
Open Tender
Civil Works
Works
120 days
Coimbatore corporation
As per tender doucuments
5 documents required · 5 mandatory
₹0
₹20,000
22 Apr 2026
2 Mar 2026
6 Mar 2026
2 Mar 2026
5 Mar 2026
2 Mar 2026
Dismantling the existing damaged RCC slabusing Electric Power Breaker as per deparmental officer etc., Complete
Earth work excavation in all kinds of soil including sand, silt, wet sand under water, black cotton, stiff black cotton, clay, hard stiff clay, hard red earth, murram, stoney earth, gravel and shales etc. excepting all kinds of rock and boulders exceeding 0.014 c.u.m, in volume including rough dressing and dumping the ecavated materials away from work site manually within 50m initial lead and 2m initial lift as per the direction of Engineer-incharge. departmental officers etc complete
Cement concrete 1:4:8 (one cement, four sand and eight aggregate) using 40mm hardbroken granite stone jelly for foundationincluding dewatering if found necessary andlaid in layers of not more than 15 cm thickand compacted etc.,complete
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 1OOCFT
Supplying and erecting SHUTTTERING including necessary supports for plane surfaces such as Drain walls etc, using mild steel sheets of size 90cm X 60Cm and BG 10 stiffened with welded mild steel angles for boarding supported by Casuarinas props at suitable intervals etc., complete complying with standard specification and as directed.
Flooring with Ellis Pattern using 6mm Chips(No Sand to be Used)
Supplying and fixing Roofing with PPGL Steet iron corrugated sheet 0.47 mm thick including necessary bolt,nuts and bitumen washed etc., completed - 10 m2
Supplying and fixing Supplying of Laser Cutting Sheet For Grill and Gate and Ornamental Grill including necessary bolt,nuts and bitumen washed etc., complete complying with standard specification.
Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 4042Kg/M3, Thermal conductivity (KValue) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.
Design,Supply and Erection Tensile Membrances Structure of high tensile strength, primary and secondary steel ,Jhardware and accessories, including the fabrication of steel structure made out of MS structural steel tubular section of high yield strength as per relevant IS codes. The tensile membrane roof covershall be of PVC coated polyester composite membrane of approved make and quality including membrane cutting seaming and HF welding as per manufacturer standards. The membrane shall be fixed to MS structural members with necessary SS plates, lugs, clamping plates as required. The membrane shall be stretched and tensioned as per the design approved. The Membrane shall be flame resistant, fungicide finish, high tear out force and continued tear out force,well wieldable, good UV resistance, high water pressure resistance and very low maintenance. This work to be executed with specialized agency. etc complete as per the direction of the Departmental officers.
Plastering with cement motar in cm 1:5 (one cement and five sand) 12mm thick in all floors complying with standard Specifications
Supply and fixing of mild steel for Various work with necessary locking arrangements including cost and conveyance etc.,as directed by departmental officer etc., complete.
Reinforced Cement concrete 1:1.5:3 (one cement, one and a half sand and three aggregate) using 20mm hard broken granite stone jelly for All RCC items of work excluding centering, shuttering, and cost of reinforcement grill but including curing finishing, vibrator charges etc., complete and also including fixing fan clamps and fixtures in RCC works wherever necessary as directed by departmental officer etc., complete.
Painting with two coats of plastic emulsion with approved colour best quality paints as per the direction of departmental officers
Painung with enamel paint two coats using good quality and approved colour for new Iron works etc., complete
Wiring with 2x1.$ sq.mm (22/0.3) PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid Pipe on wall and celling with PVC accessories, In flush with wall, with 150mmx 100mmx113mm TW switch box wall 3mm thick Hylem sheet cover for $A 3 pin non inter locking CS Plug with continuous earth wire connection of.14 SWG TC wire and making good of the open PVC plug point
Wiring with 2x 1.5sq.mm PVC insulated unsheathed SC.CU.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall,with 150mm x100mmx113mm TW switchbox with 3mm thick Hylem Sheet Cover for 5A 3Pin non interlocking CS Plugwith continous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC Plug Point
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable Pipe on wall and celling with PVC accessories with 150mmx100mmx63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point
Supply and fixing of Single box type 4°40W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of Ac ceiling fan 1200mm including 300mm downrod etc complete
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. Sd-347
Supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting .sd - 454
Conveying the excavated earth from the site to the distance of 15kms out side of the city limit including all initial lead, lift, loading and unloading with transportation charges etc complete as per the direction of departmental officers.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_804133.xls
BOQ • 0.34 MB
ITB.pdf
Additional Documents • 0.19 MB
BuildingSingle.pdf
Tender Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .