Tender Value
₹74.5 L
EMD Value
₹1.4 L
Closing Date
10 Jan 2022, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
CWE/P-26/2021-22 SPECIAL REPAIR / REPLACEMENT OF VCB PANELS AGAINST BER UNDER GE (WEST) PATHANKOT
2021_MES_478584_2
CWE/P-26/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (West) Pathankot
class C and above Category (b) (ii)
10 documents required · 10 mandatory
₹1,000
GE (West) Pathankot
₹1.4 L
Yes
4 Feb 2022
4 Dec 2021
12 Jan 2022
4 Dec 2021
10 Jan 2022
27 Dec 2021
Amount
Supply , installation, testing and commissioning of Scada Compatible, including energy management system indoor type vacuum circuit breaker of 10 panel Switchboard (2 incomer, 1 Buscoupler with bus raiser, 7 Outgoings) with possibility of future extension at one side, capacity 11 KV, 800 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 500 MVA at 11 KV , 26.3 KA breaking capacity for 3 sec, totally enclosed with extended Copper bus bar of 800 Amps for each phase, floor mounting, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vaccum interrupters , with each pole individually encapsulated by epoxy insulations and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks, manual and automatic motor charged independent closing/ tripping spring, trip free operating mechanism with closing and tripping push buttons and mechanical breaker, Full voltage sleeve (PVC sleeve not accepted) insulated Copper bus bar of 800 Amps, including Power pack of 110V DC back up system & all protection, indication, Operation, monitoring and control and accessories as per the specification :-
(i) VCB 800 Amps for Incomers & Buscoupler, VCB 630Amps for Outgoing, should be designed and tested in acoordance with IEC : 62271-100/200 or IS -3427. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (for Incomer)
(ii) 200-100A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (for outgoings) - VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA -Core 2: 3P, 20VA ( only for Incomer feeder)
(iii) Drawout type (Plug-in design not accepted), IEC 61850 Edition 2.0 complient Numerical relay having protections of 50, 51, 50N, 51N, 86, 95 .R. (Additional 27, 59 functions are required in Incommer panel relay)
(vi) Modbus (RS485 port) Multifunction Meter of Acc Class 0.5, having facility to see KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc.
(vii) 8 window Annunciation with Hooter
(viii) Trip circuit supervision relay (feature of numerical relay)
(ix) LR & TNC switch
(x) Power Pack (230V AC to 110V DC).
(xi) VCB trolley should have integral spring charging handle.
(xii) Complete panels shall be made of 2.00mm sheet and doors & endcovers shall be made of 2mm CRCA sheet.
(xiii) Castle lock for all the feeder. Interlock between Incomers and Buscoupler. Buscoupler & Raiser panel will not have CT, PT, Relays, Meters etc.
(xiv) Relevent Type Test reports for VCB to be submitted
(xv) Calibration should be done by VCB authorised OEM
(xvi) Warranty period of complete panel should be 24 months from date of supply of panels and training should be given for one week after installation to MES staff
(xvii) Note : Any other separe parts technically necessary for operation of above VCB deems to be included in quoted rates & rates are including of disconnecting and dismentling the Old existing VCBs and shifting and depositing to MES store yard as directed.
Supply , installation, testing and commissioning of Scada Compatible including energy managment sysyem indoor type vacuum circuit breaker of 3 panel Switchboard (1 incomer, 2 Outgoings) with possibility of future extension at one side, capacity 11 KV, 630 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 500 MVA at 11 KV , 26.3 KA breaking capacity for 3 sec, totally enclosed with extended Copper bus bar of 630 Amps for each phase, floor mounting, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters , with each pole individually encapsulated by epoxy insulations and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker ,, Full voltage sleeve (PVC sleeve not accepted) insulated electrolytic Copper bus bar of 630 Amps ,including Power pack of 110V DC back up system & all protection, indication, Operation, monitoring and control and accessories as per the specification.
(xv) Complete panels shall be made of 2.00mm sheet and doors & endcovers shall be made of 2mm CRCA sheet. (xvi) Relevent Type Test reports for VCB to be submitted. (xvi) Caliberation should be done by VCB authorised OEM (xvii) Warranty period of complete panel should be 24 months from date of supply of panels and training should be given for one week after installation to MES staff
(xvii) Note : Any other separe parts technically necessary for operation of above VCB deems to be included in quoted rates & rates are including of disconnecting and dismentling the Old existing VCBs and shifting and depositing to MES store yard as directed.
Supply, laying and testing cable HT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 240 sqmm 3 core, complete all as specified and directed.
Supply, laying and testing cable HT XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 120 sqmm 3 core complete all as specified and directed.
Supply, laying and testing cable HT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sqmm 3 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable, pole foundation, stay, laying of pipe etc complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed.
Supply and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm complete all as specified and directed.
KEWAL SONS
M/s Trade Linker Associates
KR POWER INFRA INDIA PVT LTD.
TRIVENI CONSTRUCTIONS
M/S Raghuvanshi Builders
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .