Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.4 LAccepted-AOC 114 PIYALI APPARTMENT RAJDANGA GOLD PARK RAJDANGA GOLD PARK KOLKATA WEST BENGAL 700107 | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹84.4 L+₹5.0 L (6.24%)Rejected-Finance 230 S N ROY ROAD SAHAPUR COLONY KOLKATA WEST BENGAL 700038 | KOLKATA | WEST BENGAL | 700038 | L2 | Rejected-Finance Quoted Higher Rate | |
| 3 | L3₹85.1 L+₹5.7 L (7.15%)Rejected-Finance H 144 358 N L CHATTERJEE ROAD RAMNAGAR P O RAIPUR MAHESHTALA KOLKATA 700141 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700141 | L3 | Rejected-Finance Quoted Higher Rate | |
| 4 | L4₹1.0 Cr+₹21.1 L (26.6%)Rejected-Finance | L4 | Rejected-Finance Quoted Highest Rate |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
13 Jan 2025, 1:00 pmClosed
SE,KHEC,PWD
Kolkata Health Electrical Circle, P.W.Dte KIT Annex Building, 5th Floor KOLKATA-700 073
Construction of proposed new building (BG9) opposite to Centenary Building within the campus of NRS Medical College Hospital, Kolkata-Electrical work---SITC of Solar Power Plant.
2024_WBPWD_787680_1
WBPWD/SEKHEC/CKHED/eNIT19/ 24-25
Open Tender
Solar Power Plants
Item Rate
60 days
NRS Medical College Hospital
Please refer Tender documents.
7 documents required · 7 mandatory
₹2.3 L
Office of the SE,KHEC,PWD
25 Jun 2025
20 Dec 2024
15 Jan 2025
20 Dec 2024
13 Jan 2025
31 Dec 2024
27 Dec 2024
Amount
Supply, Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of C-Si Mono/C-Si Poly/ Mono PERC halfcut silicon solar cells, necessary protections,earthing, mounted on GI structure of suitable strength with incorporation of following components as required to complete the project successfully:- a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5% PV modules used in solar power plants systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. [Make: Vikram Solar/Adani/SOVA/Goldi Green/BHEL/PV Power Tech/ Lubi/ Nano/Maxx/Navitas/Navi Solar/Tata Solar/Panasonic/WAAREE]
b) Power Conditioning Unit (PCU) of 350-800 V or higher DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. [Make:ABB/Thea/Delta/Schneider/Sungrow/Power one/ SMA/Solar Edge/ Solis/Frontier/Growatt)
c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) The proposed PV module panel frame structure shall be so fabricated as to be grouted on Roof top on its legs. The legs of the structure shall be fixed and grouted in the PCC/RCC foundation column made with 1:2:4 cement concrete. The foundation shall support SPV modules at a given orientation, absorb and transfer the mechanical wind speed of 120 KM/hr (minimum). f) Conventional type Lightning protection of adequate quantity as per design, should be approved by EIC. g) Surge voltage protection system as per guideline. h) Connections & Interconnections by supplying & fixing of adequate size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables(Make:RR Kabel / Polycab /Havells) between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Terms and Condition:
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. Waranty documents of SPV modules,(and other items if any) should be generated in favour of Executive Engineer-II, Central Kolkata Health Electrical Division, PWD
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
The above rate should be quoted inclusive of all the Labour Welfare Cess, taxes & duties, with cost of maintenance, servicing, supply & replacement of spares for 5 (Five) years from the date of commissioning.
Defect Liability period 5 (Five) Year
switching avo Electro Power Ltd (BID ID -5953245)
M/S INSILICA (BID ID -5984152)
MEGA SOLAR ENERGY (BID ID -5972041)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .