| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | ₹7.5 L Quoted ₹7.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹8.9 L+₹94,340 (11.9%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹8.9 L+₹94,340 (11.9%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹9.1 L+₹1.2 L (14.8%)Rejected-Finance | ₹9.1 L+₹1.2 L (14.8%) | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
7 Dec 2023, 6:00 pmClosed
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR/MAINT OF CEILING FAN, EXHAUST FAN, WALL FAN and GEYSERS OF OTM/MD ACCN OF DMSRDE, MES COLONY and WAR MEMORIAL COLONY UNDER GE (I) R and D KANPUR.
2023_MES_627925_1
8355/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹24,000
Yes
9 Feb 2024
11 Nov 2023
15 Dec 2023
11 Nov 2023
7 Dec 2023
24 Nov 2023
11 Nov 2023 - 23 Nov 2023
Amount
Celing Fan (1200/1400 mm sweep)
Disconnecting electrically, taking down existing ceiling fan any type and capacity with due care,and refixing the same after repair work with all accessories all as spfd and directed.
Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified. Note :- 1. Repairs will be measured and paid separately under respective items.
Rewinding of AC ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block complete and all as specified.
S&F Ceiling fan capacitor AC 440 volts 2.5/3.15 mfd 50HZ complete and all as specified.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge.
Replacement of ball bearing set suitable for ceiling fan upto 1400mm sweep complete and all as specified
Cleaning thoroughly ceiling fans (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long.
All as per item No 10 but of size 1 Mtrs long
All as per item No 10 but of size 1.5 Mtrs long
All as per item No 10 but of size 2 Mtrs long
All as per item No 10 but of size 3 Mtrs long
All as per item No 10 but of size 4 Mtrs long
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge.
S&F of ceiling fan clamps for fixing with fan rod incd nut, bolt, lock pin, rubber real and complete all as specified & directed.
S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers complete all as specified & directed.
Exhaust/ Pedestal/ Air circulatory Fan
Disconnecting electrically, taking down existing Exhaust/ Pedestal/ Air circulatory Wall Fan any type and capacity with due care, dismantling blades and handing over to user for repairing from MES with all accessories all as spfd and directed.
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified.
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified.
S&F fan capacitor of 3.15/4 mfd 50HZ complete and all as specified.
Replacement of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete and all as specified.
Cleaning thoroughly exhaust/wall/podestal fan 225 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
S&F in replacement of fan blade set plastic suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
S&F in replacement of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
Desert cooler
M & L for taking down/out desert cooler from existing place and removing old paint from the body of desert cooler and applying painting on desert cooler external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed.
M & L in replacement of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler as per sample complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
Supply and fixing in replacement of water lifting pump submersible type 220 -240 Volts 50 HZ as per sample complete all as specified and directed. Make : Vansal model No OASIS SX6 (Submersible ) or equivalent make as approved by GE.
Supply & fixing in replacement of kit fan motor of desert cooler as per sample, 230 volts complete with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed. Make : Crompton / Havells / Khaitan / Usha.
S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed.
M & L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed
S & F of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed. Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
M&L for dismantling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as spfd and directed..
Disconnecting, dismantling old u/s indicator lamps and replaced with new all as spfd and directed. Make Anchor/Kay/Standard
Dismantling old PVC Water distributor four way and refixing with new as per sample and all as spfd and directed.
S&F in replacement of existing UNSV desert cooler blade as per sample and fix in the desert cooler and all as specified and directed by Engr-in-Charge. Make. Cromton graves.
Geyser
Disconnecting, dismantling and taking out and refixing after repair old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site all as spfd and directed.
M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25/35 ltrs capacity of any make / type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of chromium plated flexible copper connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
S&F in replacement of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 35 ltrs capacity and replaced with new as per sample with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply as per sample complete all as specified and directed.
M&L for disconnecting, dismantling old u/s heating element of cap 1.5/ 2 KW and replaced with new and testing on completion as per sample complete all as specified and directed by Engineer-in-Charge
M&L for dismantling old u/s syphon assembly of geyser 25 to 35 ltrs ltr capacity and replaced with new stainless steel syphon as per sample and all as spfd and directed.
M&L for dismantling old u/s inner tank of geyser and replaced with new stainless steel inner tank suitable for 25 to 50 ltrs ltrs capacity geysers of 22 SWG and hydraulically tested at 22.5 PSI pressure maintained at 90 degree centigrade as approved complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of pressure release valve with inlet coupling of superior quality as approved complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of indicator LED bulb square / round type complete with necessary connection wire of red & green colour all as spfd and directed.
M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one SP MCB 25 Amps, 240 Volts. Make : Legrand/Havells/ABB
S&F in replacement of plug top 15 Amps all as spfd and directed.
Air Conditioning
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window AC 1.5/2 Ton conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed by Engr in charge.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window AC 1.5/2 Ton capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately if required under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. (iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor
S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton cap as per sample all as spfd and directed.
S&F in replacement of Air blower moter as per sample suitable for window AC of 1.5/2 Ton capacity single phase as per sample all as spfd and directed.
S&F inreplacement of cooling coil of window type AC to1.5/2 ton all as spfd.
S&F in replacement of front grill of window type AC to1.5/2 ton cap as per sample all as spfd and directed.
Disconnecting electrically and opening the cover of split type AC of 1.5/2 Ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as directed by Engineer-in-Charge.
S&F in replacement of sealed compressor, rotary type, of any make as per sample suitable for split type AC of 1.5/2 Ton capacity all as spfd and directed.
S&F in replacement of Air blower moter as per sample suitable for split type AC of 1.5/2 Toncapacity single phase as per sample all as spfd and directed.
S&F inreplacement of cooling coil of split type AC of 1.5/2 Ton all as spfd.
S&F in replacement of front grill of split type AC of 1.5/2 Ton cap as per sample all as spfd and directed.
S&F in replacement of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd as per sample all as spfd and directed.
S&F in replacement of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton as per sample.
S&F in replacement of thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity all as spfd.
S&F in replacement of condenser fan blade suitable for window/split type AC of any make & capacity all as spfd and direceted.
S&F in replacement of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type all as spfd and directed.
S&F in replacement of discharge grill of outdoor unit of any size and type for split AC’s all as spfd and directed.
Supply and charging refrigerant R-22/R134a/R410 as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and as directed.
Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed.
Supply and fixing of copper tube as per existing and site requirement complete all as specified and directed.
Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete as per site requirement and as directed.
supply and fixing in replacement of deoxidized annealed copper tube of as per sample including brazing etc. complete all as specified and directed.
supply and fixing in replacement of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed.
supply and fixing in replacement of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed.
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia all as spfd and directed.
M & L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor's workshop including any welding / repair work reqd at site complete all as specified and as directed.
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort all as spfd and directed.
M&L for fixing/installation of split AC inner/outer or both unit as received from item No 84 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion all as spfd and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required.
M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spray painting with a coat of synthetic enamel paint of required shade complete all as specified and directed by the engineer -in -charge.
Refrigrator
Disconnecting electrically, dismantling, opening the cover of Refrigerator of any capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed by Engr in charge.
S&F in replacement of rotary type sealed compressor of Refrigerator of any capacity as per sample all as spfd and directed.
Supply and fixing in replacement of Starting relay suitable for refrigerator of any make and capacity.
Supply and fixing in replacement of Thermostat suitable for refrigerator of any make and capacity.
Supply and fixing in replacement of Capillary tube as per site requirement of refrigrator/water cooler any type.
Voltage Stablizer
Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 1 to 5 KVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc all as spfd and directed. Note : Spare parts will be measured and paid seperately under respactive items.
Supply and fixing in replacement of Main relay of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of Main control circuit (PCB) of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of replacement of sensor transformer of voltage stabilizer 1 to 5 KVA as per sample. .
Supply and fixing in replacement of voltmeter of voltage stabilizer 1 to 5 KVA as per sample. .
Supply and fixing in replacement of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 KVA as per sample.
Taking out old burnt winding of transformer and re-winding the same with super enameled copper winding wire (existing size) for 1 to 5 KVA voltage stabilizers including all necessary insulating material and testing complete.
Water Cooler
Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair all as spfd and directed.
S&F in replacement of sealed compressor as per sample suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs as per sample.
S&F in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler.
S&F in replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator.
S&F in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample.
S&F in replacement of Starting relay of water cooler as per compressor requirement.
S&F in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement.
S&F in replacement of Over load protector of water cooler as per sample suitable for water coolers.
M & L for providing PVC rounded 3 core 1.0 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells/Plaza.
All as per item No 111 but copper cable of size 1.5 Sqmm.
All as per item No 111 but copper cable of size 2.5 Sqmm.
santosh electronics
S B ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .