Providing electrical repairing materials for LED lights installed in the municipal area.
2026_DLB_550773_1
29
Open Tender
Civil Works
Percentage
30 days
bahadurpur
rafered doucment
2 documents required · 2 mandatory
₹1,000
MDRISL/EO
₹30,000
Yes
22 Apr 2026
9 Apr 2026
21 Apr 2026
9 Apr 2026
20 Apr 2026
9 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Providing & Laying P.V.C./XLPE insulated & P.V.C, sheathed UnArrmoured Aluminium cable confirming to IS:1554 P-I/IS :7098 P-1 of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6%, Inner / outer sheath confirming to IS:5831 in existing RCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench/Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product/ work refer Annexure 'A attached with this BSR 16X 2 sq. mm. (insulated) | - | mtr | - | - |
| 3 | Providing & Fixing of 240/415 V AC MCB with positive isolation kA
breaking capacity (B/C/D tripping characteristic as load and site
requirement) 4 KV impulse withstand voltage, ISI
marked IS 8828(1996) /conforming to IEC 60898-1 2002, IEC
60947-2, low watt losses, trip free mechanisum, energy limiting of
class 3 as per IEC, minimum phase termination capacity of
35sq.mm., conductor line load reversibility, IP 20 contact protection
and fitted in existing distribution board/sheets, minimum electrical
operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80
A & above rating including making connections, testing etc. as
required. OEM shallhave submit NABL/CPRI / ERDA accrediated
lab type test reports & All as per pre approved by Engineer in 0.5 A to 5 A ratin | - | nos | - | - |
| 4 | Double pole MCB(With B/C curve tripping Characteristics) | - | nos | - | - |
| 5 | Four pole MCB (With B/C curve tripping Characteristics) | - | nos | - | - |
| 6 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2)/Copper
(IEC 60028) bus bar by means of SMC/ DMC type insulator with
standard short circuit withstand capacity, high tensile nuts and bolts
spring washers in existing panel including bending, cutting in
required shape and size and colour coding with heat shrinkable PVC
sleeves. All as per pre approved by Engineer in-charge. For additional
technical parameters of products/ work, refer Annexure "A" attached
with this BSR | - | nos | - | - |
| 7 | Main Panel Street Light Control Panel Commissioning Kiosk type
weathe proof panel out door main cubic panel size 750x1250x500
they shall be in two section comaring as follows BSR 2017 (59.57) | - | nos | - | - |
| 8 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 110Volts grade PVC insulated flat twin core sheathed solid aluminium 4 SQ Mм
2 CORE FLAT | - | mtr | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.91 MB
lednit.pdf
Tender Documents • 1.89 MB
BOQ_981579.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .