Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹93 L
EMD Value
₹93,000
Closing Date
30 Apr 2024, 1:00 pmClosed
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
The electrical safety, the work of repairing the damaged 33 KV underground and overhead lines by constructing lines from underground/overhead cables and conductors.
2024_PVVNL_922872_1
T-130/EDC-I/B/2023-24
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
SE EDC-I
₹93,000
6 May 2024
23 Apr 2024
30 Apr 2024
23 Apr 2024
30 Apr 2024
23 Apr 2024
Amount
fctusl Iyku ;kstuk ds vUrxZr fo|qr uxjh; forj.k [k.M&cqyUn”kgj ds dk;Z{ks= esa {kfrxzLr 33 dsoh Hkwfexr ,oa vksoj gSM ykbZuks dks fo|qr lqj{kk ds n`f’Vxr j[krs gq, Hkwfexr@vksoj gSM dsfcy] daMDVj ls ykbZu fuekZ.k dj ejEer djus dk dk;ZA
Safe carriage of S.T.Pole, SP-55 11mtr long, from store center to site store with loading & unloading at both ends respectively distance within- 0 to 50 Kms.
Pcc Poles 9 mtr. long
ST Poles 13 mtr. long
Loading, Safe carriage & unloading of heavy stock material V Type X-Arm, Disc Insulator, Pin Insulator, Channal MS Angel, Stay Set Complete, Earthing Rod And ETC from store center to site store with proper stacking of material, distance within-150Kms.
Loading/Unloading/carriage 33 KV XLPE 3x120sq mm. cable from store to site. distance within 50 Km.
Loading/Unloading/carriage 33 KV XLPE 3x300sq.mm cable from store to site. distance within 50 Km.
Loading/Unloading/carriage ACSR Dog Conductor from store to site. distance within-50Kms.
Excavation of For Each and grouting of Single Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone Pad etc. as per actual site requirement
PCC/ST Poles 9/11/13 mtr. long
Erection of Single pole all size as per RESPO Drawing, fitting with all accessories Pin Insulator, F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
PCC/ST Poles 9/11/13 mtr. long
Laying sagging stringing and binding and jumpering etc of following ACSR, Dog Conductor off size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work. ACSR Dog Conductor
Erection of Double pole ST Pole 11 mtr long of 33 KV fittings as per RESPO Drawing Top Channal, Dropper Channal, X Bracing Set, Disc Insulator, Pin Insulator, Guarding Angle F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
PCC/ST Poles 9/11/13 mtr. long
Construction of Kicking Block/Pole Plinth of each Poles above the ground level with Cement, Concrete Complete in all Respect
Providing of stay set
Fixing & Grouting of stay set including the work of nozelling etc. as per RESPO manual and also including the cost of all grouting material, labour, T&P etc required for proper completion of work.
Providing of earthing rod
Fixing of earthing rod and Wire as per RESPO manual and as per direction of supervising engineer including the cost of labour, T&P etc. required for proper completion of work.
Cutting/drilling/Welding of MS Channel Top Channal, site channel, site angle, Dropper Channal & Cross brassing angle and MS mattriel Including the work of fixing on STP Pole for construction of the line.
Making Jumpers on Section Points, by fixing of proper sizes, suitable for ACSR Conductor. Sectional Double/Four Pole.
Provading of Danger Plate.
Fixing of Danger Plate.
Provading of MS. Angle off size
Fixing of MS. Angle off size
Provading of MS. Channel off size
Fixing of MS. Channel off size
Provading of 33 KV GARDING ANGLE
Fixing of 33 KV GARDING ANGLE
GARDING of line
Providing of G.I Wire
Provading of 33 KV V TYPE CROSS ARM
Fixing of 33 KV V TYPE CROSS ARM
Fixing of 33 KV Disc Insulater
Fixing of 33 KV Pin Insulater
Providing of G.I Pipe as per size of cable
Fixing of G.I Pipe as per size of cable
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.
Drilling of Two Parallel bores by trench less Method by horizantal Boring by HDD Machine/Moaling by bockey at RESPO ground Level
Providing of HDPE Pipe for cable
Fixing of HDPE Pipe for cable
Providing of Interconnecting 6 Mtr. Long Pieces of HDPE Pipe shocket.
Fixing of Interconnecting 6 Mtr. Long Pieces of HDPE Pipe shocket.
Laying of 33 KV cable with Making open trench with send ston slabe and bricks etc with provision of cable hanging.
Digging of Pits Of Size 4 Mtr X 4 Mtr X 1.5 Mtr. For Cable Loop
Restoration of Pit After Laying Of Cable loop
Laying And Pulling of 33 KV XLPE Cable Off size Throug HDPE Pipe
Providing Of Heat Shrinkable 33 KV Cable Jointing Kit Indoor & Outdoor Suitable For 120/300sq.mm. XLPE Cable
Fixing Of Heat Shrinkable 33 KV Cable Jointing Kit Indoor & Outdoor Suitable For off size XLPE Cable
Providing Of Heat Shrinkable 33 KV Cable Jointing Kit stat throw Suitable For off size XLPE Cable
Fixing Of Heat Shrinkable 33 KV Cable Jointing Kit stat throw Suitable For off size XLPE Cable
Hi Port Test For 33 Kv off size XLPE Cable
Hoisting of 33 KV off size XLPE Cable On Double Pole/Four Poles Structure through GI Pipe off size Fixed On Pole Structure Including its Jumpring Complete with Clamps Bolts and Nuts.
The follwing material will be provided & Fixing by the contractor
MS Clamp Off size
Nuts & Bolts difference size With Barsher GI off size
Stay Insulator
F Bracket
ALL paint
Red oxide paint
Rout marker
Stone Pad
Liasoning charge for NHAI/NPP BSr/Railway Permision
Painting of Pole
Road Restoration charge of kachha Road
Road Restoration charge of packka Road
Carrige of all dismantle mattril sit to stor center BSR.
Vivek Electricals
NEHA ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .