| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.2 L+₹4.7 L (16.6%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Other than Lowest | |
| 3 | Rejected-Technical RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | - | Rejected-Technical No, Not enlisted in required category of work. |
Tender Value
₹34.7 L
EMD Value
₹69,460
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
PROVIDING SERVICES OF COMPREHENSIVE MAINTENANCE OF PRECISION AC (PDX) PLANT OF CAP 4 X 10 TR LOCATED AT DIPAC UNDER GE (U) PM DELHI CANTT10
2023_MES_605644_1
GE(U)/PM/D-33/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
360 days
DELHI CANTT-10
MES contractor enlisted under class D category c (i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and cat
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹69,460
Yes
17 Aug 2023
26 Jun 2023
26 Jul 2023
26 Jun 2023
24 Jul 2023
10 Jul 2023
Amount
Periodical, preventive and comprehensive maintenance of direct expansion Microprocessor based precision AC(PDX) unit of 4 x 10 TR sensible capacity precision AC unit with 5500 CFM as per the specifications air cooled condenser at underground data centre for DIPAC at Delhi Cantt for equipments as mentioned as below:- (a) DX Microprocessor based precision AC 4x10 TR sensible with 5500 CFM variable capacity scroll compressor as per the specifications air cooled condenser with stepless variable speed fans for winter operation, digital scroll compressor in each unit with refrigerant circuits & connected items. (b) PAC with bottom discharge air flow. (c) Outdoor condenser unit with copper coil with aluminum fins and social fans/speed controller motor. (d) In built sequential controller for operating unit in N + 1 configuration designed for 22 + deg (return air temperature 50% ± 5% Rh and 43 deg C amient tem). (e) Electrical control panel double earthed alongwith timers for delayed start of units (03 Nos. working + 1 standby). (f) Commercial air curtains units for prevention of dust 7 conditional air losses 3 Phase 440 V, 50 Hz complete with fittings and accessories so as to produce 1 to 1 5m/sec air velocity at floor level for door opening size 58” x 90” all as specified and as directed.
NOTE FOR ITEM NOS. 1.00 :- (a) The comprehensive maintenance works under this contract shall be done through respective OEM i.e. VERTIV. The contractor will have to submit MoU on stamp paper of Rs 100/- duly notarized, as specified in Performa (On serial page No. 96 & 97), within Fifteen days from date of Acceptance of tender, failing which the contract shall liable to be cancelled and further action to be taken as per policy in vogue on account of contractors default. (b) The contractor should ensure that fortnightly periodical/ preventive maintenance services to the Eqpt/ AC unit to be carried out and submit the inspection report (duly signed by the user/ user's rep) of Equipment conducted by the OEM with in two days of visit to the Engr-in-Charge, failing which recovery of Rs. 2000/- per Equipment per visit shall be deducted from contractors dues. (c) Contractor has to carry out all major and minor break down/repairs pertains to complete machineries of Pericision AC Plant including topping of refrigreant gas as required rates quoted is deemed to be included for all except any damage due to natural disasters such as flash, floods, earth quake, cyclone etc. (d) If complaints were not attended within six hours the following penalties will be imposed and deducted from payments. :- (i) Rs. 3000/- per complaint for not attending the complaint and keeping pending from 6 hours to 12 Hour for each complaint. (ii) Rs. 5000/- per complaint for not attending the complaint and keeping pending 12 hours to 24 hours each complaint.
Material & Labour for carried out cooling assessment of all four units of direct expansion Microprocessor based precision AC(PDX) 10 TR sensible capacity precision AC and submit the report to the Engr-in-Charge complete all as specified and as directed.
Material & Labour for replacement of filters of the PAC units complete all as specified and as directed.
Supply & fixing MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and as directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing in repairs Copper lugs for cable of cross sectional area 10 Sqmm complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with copper conductor of cross sectional area 10 Sqmm, 4 core with galvanized steel strip or wire including taking down old unserviceable one complete all as specified and as directed. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .