Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.2 LAccepted-AOC | 1 | Accepted-AOC The lowest bidder M/s Ramprasad Chhotelal Batham is being accepted please. | |
| 2 | 2nd₹30.9 L+₹59,831.65 (1.98%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹30.9 L+₹61,874.15 (2.04%)Rejected-Finance 1006 MANAK CHOUK MHOW DIST INDORE MADHYA PRADESH453441 | INDORE | INDORE | MADHYA PRADESH | 453441 | 3rd | Rejected-Finance 3rd | |
| 4 | 4th₹31.4 L+₹1.1 L (3.70%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | 4th | Rejected-Finance L4 | |
| 5 | 5th₹31.9 L+₹1.6 L (5.34%)Rejected-Finance 498 GANNAUGHT ROAD MHOW MP PIN 453441 | MHOW | INDORE | MP | 453441 | 5th | Rejected-Finance L5 |
Tender Value
₹35.9 L
EMD Value
₹71,900
Closing Date
16 Sept 2024, 6:00 pmClosed
GE AWC MHOW
GE (AWC) Mhow
PROVN OF 3M WIDE CEMENT CONCRETE PATH (APPROX410M) BETWEEN B MESS T JUNCTION ROAD TO FOLLOWER QUARTERS ROAD JUNCTION TRG ACTIVITIES INSIDE ARMY COLLEGE UNDER GE (AWC) MHOW
2024_MES_667816_1
8754 GE(AWC) /MHOW / OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹71,900
Yes
30 Oct 2024
25 Jul 2024
17 Sept 2024
26 Jul 2024
16 Sept 2024
8 Aug 2024
Amount
M&L earthwork in excavation by meachanical means (hydraulic excavator) over areas (exceeding 30cm in depth,1.5m in width as well as 10sqm on plan) in all kind of soil including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m as directed by engineer in charge complete
M&L Moorum (or) Red bajri filling in pavings laid in layers not exc 15 cm thick, spread, levelled and rammed including watering
Rolling over formation surfaces by 8-12 ton power roller (static and vibratory)in cutting surface to achieve field compaction at least to 98% of modified proctor density of existing soil as directed.
M & L moorum/Red bajri fillings in floors or pavings laid in layers n exc 15cm thick of quarried stone ,interstices filled, surfaces formed and rolled and consolidated to required gradient and camber 150mm thick GSB in two layers of 75mm each(compacted thickness) complete all as specified and directed
M & L PCC 1:3:6 type C2 using 40mm graded agrregate 100mm thick as in sub base/ Sub floor/ pavings as specified.
M&L for 200mm thick cement concrete work in pavement/ hardstanding of flexural strength 40kg per square centimetre in field using minimum 400kg of cement per cubic metre thickness of concrete 25cm or less including cutting of joints complete all as specified in the respective clause of SSR part -I & PS clause of tender document as directed
M & L finishing the surface of concrete roads and pavements by belting complete all as specified and directed.
M&L forming contraction joints 65mm deep X10mm wide filled with sealing compound grade A all as specified and directed.
M & L forming 12mm Thick Expansion joints filled with pre formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' Concrete thickness 200mm all as specified and directed.
M & L polythene film black 50 micron laid floors and pavings as specified.
Use and waste form work to sides of concrete for fair finished flat surfaces of concrete all as specified and directed.
S & F TMT bars 10 mm dia and over, cut to length, bent to shape as required incl cranking, bending spirally for hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
M&L reinforced concrete pipes class NP2 laid and jointed complete with collars all as specified and directed.
M&L for brick work with fly ash bricks, modular bricks, straight or curved on plan exc 6 m mean radius, built in cm 1:6 including demolition of brick work all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps, seismic and other similar bands, plinth courses, string courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones bed plates, etc and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary use and waste of form work, complete all as specified and directed.
M & L for rendering 10mm thick plaster in CM (1:6), of manholes, concrete surfaces, finished even and smooth (without using extra cement) of cement complete all as specified and directed
Excavation in trenches in any type of soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out for laying of cables/pipes etc including forming bottom surfaces to the required level/slope complete.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick in any type of soil complete.
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned /consolidated thickness complete all as specified and directed
M&L for cement concrete1:4:8 type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in coping & the like etc. including weathering slightly rounded/chamfered angle with & including necessary use & waste of form wk for fair finished surfaces complete all as specified and directed.
Supply and laying galvanised iron pipe 'light Grade'50 mm in trenches , under floors, roads, along poles for protection of cables with all necessary fittings, including sealing ends complete all as specified and directed .
Supplying, laying and testing cable XLPE insulated 10 sqmm 4 core, screened, PVC bedded galvanized steel strip or wire armoured electric power cables ( heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed .
Supplying and laying unreinforced PCC Cable protection cover , Class LV ,Type1 flat ,size 250mm x 150mm x 40mm as cable protection laid flat width wise complete all as specified and directed
Material and laying steel tublar swaged poles with cast iron base plate, 410-SP-31, as per sample of length 09 Mtrs duly painted, finial taper plug,bolts, nuts,& screws complete all as specified and directed.
S & F Bracket for street light fitting made out of GI tubing 40 mm light grade pipe 2' x 1 -1/2' 135 degree bend with duly aluminium painted ,cutting , welding and two MS bracket with nut bolts and washer bracing to pole/on fencing for street light fittings.
Supply, Installing ,Testing and commissioning of LED Street light Fitting with a nominal system 5300 lumen output of lumens , minimum system efficacy of 115 lm/W and total power consumptiion not exceeding 45 W ( including driver ) . The luminaire shall have a rated system lifetime of 50000 burning hours at L70B50. The Luminaire should have a colour temperature of 5700 - 6500 K and CRI > 80 . The Luminare shall meet IP66/Ik07 or IK08 rating with THD<10% and PF > 0.95 . The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85 % transmittance . The fittting should have an internal SPD of minimum 4 KV .The driver should have phase to phase protection for 8 hours . The luminaire should have a NABL approved LM79 report . LM80 report from the LED manufacture is a must along with biological report . Luminaire and the driver shall ben BIS certified seperately and shall posses seperate '' R'' numbers Fitting should include nut bolt and SS screws for suitably fixing on the existing solar street light pole complete all specified and directed. Note :-The Street Light should have a minimum 05 years warranty submitted by the tenderer from manufacture.
Supplying and fixing in replacement of PVC junction box of size 200mmX160mmX98mm , including connector block , two holes for incoming and outgoing cables, providing cable glands double compression as per requirement, providing DIN rail for mounting 6 Amp MCB and Clamps made out of MS Flat Iron 25X4mm, MS hexagonal bolts, nuts and washers for arrangements to pole/ surfaces complete all as specified and directed by Engr-in-Charge.
M&L for rigid non-metallic PVC FRLS conduit heavy duty of size 20 mm external dia, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, to be fixed along the pole complete all as specified and directed.
S&F weather proof elastomer sheathed flat twin core Copper wire cable of size 1.5 sqmm for connection of street light, complete, all as specified and directed.
M/S UnitedConstruction (BID ID -3091442)
Narayandas Phoolchand Mishra Infrastructures Pvt. Ltd. (BID ID -3095777)
yash enterprises (BID ID -3096938)
M/S GARG CONSTRUCTION (BID ID -3096828)
SATHI ENTERPRISES (BID ID -3091328)
Bharadwaj Builders (BID ID -3096408)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .