| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69 LAccepted-Finance GOVT CONT VILLAGE AND P O NANIKHAD TEHSIL BHATTIYAT AND DISTT CHAMBA H P | ₹69 L | L1 | Accepted-Finance ACCEPTED BEING LOWEST |
| 2 | L2₹72 L+₹3 L (4.35%)Rejected-Finance | ₹72 L+₹3 L (4.35%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹78 L+₹9 L (13.0%)Rejected-Finance | ₹78 L+₹9 L (13.0%) | L3 | Rejected-Finance REJECTED |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Robin Mahajan L2 | TECHPRO ENGINEERING COMPANY L3 | A.R ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of Horizontal spindle,horizontal/radial split casing and suction(Backpull out arrangement ) single/double/multistage Centrifugal pumps or combination of pumps in series/parallel of KSB/Mother and Platt/jyoti /kirloskar/BE/maxflow/beacon weir make conforming to BIS-1520-1980(latest with up to date ammendment )read with BIS: 9137-1978(Latest addition suitable for lifting raw water of under mentioned characterstics with impellers of bronze/suitable alloy,priming funnels,casing ring and shaft sleeves of bronze/suitable alloy,shaft of suitable steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/Cast steel Base plate( Base plate to be from the principle manufacturer of pumping set ) to sleeper in/sqirral caze screen protected drip proof electric induction motor of Kirlosker/NGEF/Crompton /Siemen/Jyoti /BHEL/GEC/ABB conforming to BIS: 325-1978 read with BIS : 900-1965 (Latest with up to date amendments ) it should include the cost of bearing,nuts,and bolts ,painting etc and shall be suitable for operation as per data given below. 2 Nos working sets | 2 | Sets | 36,00,000 ₹72,00,000 | 39,00,000 ₹78,00,000 | 34,50,000 ₹69,00,000 Lowest |
| 1.01(A) SITE CONDITIONS :- i) Location of site :- The site is located at a distance of 25 KMs from Nanikhad NH 154 A ii) The altitude of place in which the motor is intended. 539 Metres above MSL. iii) Type of current :- AC three phase supply with freqency of 50 cycles per second. iv) Rated Voltage :- 415 V = 10 v) Type of Water & its source. Clear Water iv) Charactrstics of water :- ( a) Temperature 20 C, ( b) Turbidity PPM, (c) Hardness Mg./ Litres (as Ca Co3 ), (d) pH..... , ( e) Total solids. Mg / lit. ( f) others -------- vii) Depth of well :- 10.00Mtrs. viii) L.W.L in well/ Sump well:- mtrs. ix) Max. draw down :- mtrs. x) Center line Level of Pump 539 mtrs. xi) Discharge level of highest point 985 mtrs. xii) No. of pump required :- 3 Nos 125.00 HP Each xiii) Capacity :- 9.67 LPS for each pump xiv) Static head in mtrs. 446 meters xv) Total head in metres 530.61 Meters xvi) Length of Rising main :- 2175 meters xii) Dia of Rising main :- 125 mm dia xviii) No of pomping Hrs. per day:- 8 Hrs. xix) Limits of pump operation :- (-) 25* to ( + ) 10*of total head. xx) HP of motor Drive unit :- Required BHP of pump at ( -) 10* & 25* of total head BHP with following margins multiplying factor at duty point. Whichever is higher (a) Upto 2 HP = 1.5 ( b) 2 to 5 HP = 1.4 (c) 5 to 10 HP = 1.3 (d) 10 to 20 HP 1.2 ( e) 20 to 100 HP 1.15 ( f) above 100 HP 1.10 xxi) RPM of Pumping Sets:- ______ rpm ( to be quoted by tenderer ) xxii) Test Run :- 20 hrs. continueously for 7 days. | ||||||
| 1.02Supply of digital soft starter of Allen Bradely/Schnider /ABB of reputed make of havey duty application rating 15 to 500 amper constant current / torque controll starting from comprehensive motor protection with large LCD key pad mounted on panel board & built in rear time clock complete suitable for above motor starter.= 2 Nos. | ||||||
| 1.03Providing M.S angle iron steel sheet 16 SWG steel fabricated floor mounted closed almirah type switch board powdered coated rust proof including angle iron post of suitable height & size ISA 65 x 65 x 6mm duly painted comprising and capable of mounting the following accessories . = 1 No. Note :- The drawing of panel board shall be subject to approval of Engineer -in-charge. (a) Digital Ammeter AC Supply,100 mm dia Square dial Auto electric of AE/ IMP/Havells/Schnider make of suitable range for above pumping set with selector switches conforming to BIS1248 -1983 latest with upto date ammendments.= 2 Nos. (b) Digital Voltmeter AC supply, 100 mm Square dial auto electric AE / IMP/ Havells make of suitable range for above motor with selector switch conforming to BIS 4064-1978 latest with upto date ammendmants. = 1 No. (c) Bushbar chamber having three copper bars of suitable rating for full length 3 live phases and one copper bar of half reating of half rating of full length for natural conforming toBIS 8084 -1976 and 11353 -1985 read with 5578 - 1985 all latest with upto date ammendments.= 1 No. (d) MCCB of suitable capacity of Kilburn / L&T / MEI / standard/ GEC make on incomingfeeder for pumping sets conforming to BIS 2516 -1985 ( latest edition ) with neutral linked under voltage release.= 1 No. (e) Three phases indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I&II latest with upto date ammendments. =2 Sets. (f) Digital Hour run meter of reputed/ approved make of four digit capacity conforming to BIS - 722 (latest edition).= 1 No. (g) Providing PLC of 32 IOS of Digital /Analog input/output for automatic operation of the submersible Pumps= 1 No. | ||||||
| 1.04(a) Supply of Kirloskar/ Kilburn / IVC / Fouress/ Gled /BHEL /Leader/ Kartar make Cast iron PN 1.0 double flanged actuator valve ( to be provided on Suction side ) of size one size higher than the delivery size of pump and capable of with standing nominal seat pressure of 10 Kg / cm2 = 2 Nos. NOTE:-The C.I sluice valve shall conform to BIS 780 -1984 for 50 to 300 mm dia & BIS:2906-1984for 350 to 1200 mm dia ( latest adition ) However I f seat pressure exceeds t he l imits prescribed in above mentioned BIS. than It shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seatpressure 52 Kg/cm2 as BS1414(API 600 ) (b) Supply of Kirloskar /Kilburn /IVC/ Fouress /Gled /BHEL/Leader /Kartar of suitable size cast iron double flanged actuator valve having bye - pass arangement ( to be provided on delivery side ) of size one size higher than the delivery size of pump & shall be suitable for with standing nominal seat pressure of 52 kg/cm2 of class ASA -600 asper BS-1868-API(600).= 2 Nos. NOTE:-The C.I sluice valve shall conform to BIS 780 -1984 for 50 to 300 mm dia & BIS:2906-1984for 350 to 1200 mm dia ( latest adition ) However I f seat pressure exceeds t he l imits prescribed in above mentioned BIS. than It shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seatpressure 52 Kg/cm2 as BS1414(API 600 ) (c) Supply of Kirloskar/ Kilburn /IVC/ Fouress /Gled / BHEL/Leader/Kartar make Cast iron double flanged swing check type reflux valve having bye-pass arrangement of size equal to Rising main i.e. 150 mm and shall be suitable for with standing nominal seat pressure of 52 Kg/ cm2 of class ASA-300 as per BS-1868-(API-600). = 1 No. NOTE: The C.I reflux valve shall conform to BIS 5312-1984 part -I( latest adition ) However if seat pressure exceeds the limits prescribed In BIS 5312 than it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seat pressure 52 Kg/cm2 as BS 1868 (API 600 ) | ||||||
| 1.05(a) Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex / Gloster/ Grandlay make Conforming to BIS: 1554 ( Part-I ) 1988 latest with upto date ammendments of suitable size for the pump sets offered ( one cable carrying all three phases ) including all other Electrical equipment / accessories such as thimbles,flexible pipes, solder ,nuts & bolts, cable glands etc. laid in pipes or tranches under floor.The type size & make will be subjct to approval of HPSEB authority. In case of non acceptance by HPSEB authoritties It shall have to be replaced by the tenderer free of cost.= 1 Job a) On supply side of 3-1/2 core( From HPSEB meter to Switch & Starter ) to be specified by the tender b) On motor side 3 core ( From Switch & Starter to Motor ) to be specified by the tender (b) Providing & laying double loop earthing and copper plate 600 X 600 X 3mm thick electrode complete with material such as charcoal & common salt, G.I pipes, thimbles, nuts & bolts, digging of pits G.I wire & 25X3mm copper strips as per BIS : 3043-1987 latest with upto date ammendments for above motors & other electrical equipment. = 1 Job Note:- The strip size shall be 20x3 upto 18.5 KW,25x3 for 18.5 to 37 KW , 25x5 for 37 to 55 KW & 32x5 beyond 55 KW. (c) Supply & errection of floor power factor Shunt Capacitor conforming to BIS 2834-1986 latest with up to date ammendments BHEL / GEC / Machneil / Magger / Bajaj make to raise the prevailling power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered also including L & T / Standard / Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses ( Range to be specified by the tenderer.) = 1 No. | ||||||
| 1.06Providing and fixing of pressure transmitter with digital/analog outfit to be fixed in delivery line. = 1 No. | ||||||
| 1.07Providing and laying assembly of GI pipe considering site requirement and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevent BIS codes & capable of with standing the field test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers / reducers, flanges, rubber guskets 3 mm thick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. NOTE :-Actual laying to be done final drawings to be approved by the Engineer in charge. = 1 Job | ||||||
| 1.08Providing & Fixing of HMEI 7" Screen for displaying & controlling of Parameters= 1 No. | ||||||
| 1.09Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions as per direction of the Engineer-in-charge. = 1 Job | ||||||
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
18 Mar 2024, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Dalhousie
Providing LWSS to PC habitation of C.Village Chuhan, Garh, Tarwar, Bhotan, Chonka, Draman,Teiyan, Dharoon, Kail, Samleo Uperla, Dal,Lahri, in GP Nagali, Bagdhar, Dhalog, Sudli and Mornu etc. Tehsil Bhattiyat Distt Chamba HP SH Supply and errection
2024_HPIPH_88239_1
JSVD-DLU-EA-I/19747-19796 dt. 11.03.2024
Open Tender
Civil Works
Item Wise
183 days
Chuhan
Providing LWSS to PC habitation of C.Village Chuhan, Garh, Tarwar, Bhotan, Chonka, Draman,Teiyan, Dharoon, Kail, Samleo Uperla, Dal,Lahri, in GP Nagali, Bagdhar, Dhalog, Sudli and Mornu etc. Tehsil Bhattiyat Distt Chamba HP SH Supply and errection
8 documents required · 8 mandatory
₹400
Yes
EE Dalhousie
₹75,000
Yes
30 Nov 2025
12 Mar 2024
19 Mar 2024
12 Mar 2024
18 Mar 2024
12 Mar 2024
12 Mar 2024 - 18 Mar 2024
Amount
Supply of Horizontal spindle,horizontal/radial split casing and suction(Backpull out arrangement ) single/double/multistage Centrifugal pumps or combination of pumps in series/parallel of KSB/Mother and Platt/jyoti /kirloskar/BE/maxflow/beacon weir make conforming to BIS-1520-1980(latest with up to date ammendment )read with BIS: 9137-1978(Latest addition suitable for lifting raw water of under mentioned characterstics with impellers of bronze/suitable alloy,priming funnels,casing ring and shaft sleeves of bronze/suitable alloy,shaft of suitable steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/Cast steel Base plate( Base plate to be from the principle manufacturer of pumping set ) to sleeper in/sqirral caze screen protected drip proof electric induction motor of Kirlosker/NGEF/Crompton /Siemen/Jyoti /BHEL/GEC/ABB conforming to BIS: 325-1978 read with BIS : 900-1965 (Latest with up to date amendments ) it should include the cost of bearing,nuts,and bolts ,painting etc and shall be suitable for operation as per data given below. 2 Nos working sets
(A) SITE CONDITIONS :- i) Location of site :- The site is located at a distance of 25 KMs from Nanikhad NH 154 A ii) The altitude of place in which the motor is intended. 539 Metres above MSL. iii) Type of current :- AC three phase supply with freqency of 50 cycles per second. iv) Rated Voltage :- 415 V = 10 v) Type of Water & its source. Clear Water iv) Charactrstics of water :- ( a) Temperature 20 C, ( b) Turbidity PPM, (c) Hardness Mg./ Litres (as Ca Co3 ), (d) pH..... , ( e) Total solids. Mg / lit. ( f) others -------- vii) Depth of well :- 10.00Mtrs. viii) L.W.L in well/ Sump well:- mtrs. ix) Max. draw down :- mtrs. x) Center line Level of Pump 539 mtrs. xi) Discharge level of highest point 985 mtrs. xii) No. of pump required :- 3 Nos 125.00 HP Each xiii) Capacity :- 9.67 LPS for each pump xiv) Static head in mtrs. 446 meters xv) Total head in metres 530.61 Meters xvi) Length of Rising main :- 2175 meters xii) Dia of Rising main :- 125 mm dia xviii) No of pomping Hrs. per day:- 8 Hrs. xix) Limits of pump operation :- (-) 25* to ( + ) 10*of total head. xx) HP of motor Drive unit :- Required BHP of pump at ( -) 10* & 25* of total head BHP with following margins multiplying factor at duty point. Whichever is higher (a) Upto 2 HP = 1.5 ( b) 2 to 5 HP = 1.4 (c) 5 to 10 HP = 1.3 (d) 10 to 20 HP 1.2 ( e) 20 to 100 HP 1.15 ( f) above 100 HP 1.10 xxi) RPM of Pumping Sets:- ______ rpm ( to be quoted by tenderer ) xxii) Test Run :- 20 hrs. continueously for 7 days.
Supply of digital soft starter of Allen Bradely/Schnider /ABB of reputed make of havey duty application rating 15 to 500 amper constant current / torque controll starting from comprehensive motor protection with large LCD key pad mounted on panel board & built in rear time clock complete suitable for above motor starter.= 2 Nos.
(a) Supply of Kirloskar/ Kilburn / IVC / Fouress/ Gled /BHEL /Leader/ Kartar make Cast iron PN 1.0 double flanged actuator valve ( to be provided on Suction side ) of size one size higher than the delivery size of pump and capable of with standing nominal seat pressure of 10 Kg / cm2 = 2 Nos. NOTE:-The C.I sluice valve shall conform to BIS 780 -1984 for 50 to 300 mm dia & BIS:2906-1984for 350 to 1200 mm dia ( latest adition ) However I f seat pressure exceeds t he l imits prescribed in above mentioned BIS. than It shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seatpressure 52 Kg/cm2 as BS1414(API 600 ) (b) Supply of Kirloskar /Kilburn /IVC/ Fouress /Gled /BHEL/Leader /Kartar of suitable size cast iron double flanged actuator valve having bye - pass arangement ( to be provided on delivery side ) of size one size higher than the delivery size of pump & shall be suitable for with standing nominal seat pressure of 52 kg/cm2 of class ASA -600 asper BS-1868-API(600).= 2 Nos. NOTE:-The C.I sluice valve shall conform to BIS 780 -1984 for 50 to 300 mm dia & BIS:2906-1984for 350 to 1200 mm dia ( latest adition ) However I f seat pressure exceeds t he l imits prescribed in above mentioned BIS. than It shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seatpressure 52 Kg/cm2 as BS1414(API 600 ) (c) Supply of Kirloskar/ Kilburn /IVC/ Fouress /Gled / BHEL/Leader/Kartar make Cast iron double flanged swing check type reflux valve having bye-pass arrangement of size equal to Rising main i.e. 150 mm and shall be suitable for with standing nominal seat pressure of 52 Kg/ cm2 of class ASA-300 as per BS-1868-(API-600). = 1 No. NOTE: The C.I reflux valve shall conform to BIS 5312-1984 part -I( latest adition ) However if seat pressure exceeds the limits prescribed In BIS 5312 than it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seat pressure 52 Kg/cm2 as BS 1868 (API 600 )
(a) Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex / Gloster/ Grandlay make Conforming to BIS: 1554 ( Part-I ) 1988 latest with upto date ammendments of suitable size for the pump sets offered ( one cable carrying all three phases ) including all other Electrical equipment / accessories such as thimbles,flexible pipes, solder ,nuts & bolts, cable glands etc. laid in pipes or tranches under floor.The type size & make will be subjct to approval of HPSEB authority. In case of non acceptance by HPSEB authoritties It shall have to be replaced by the tenderer free of cost.= 1 Job a) On supply side of 3-1/2 core( From HPSEB meter to Switch & Starter ) to be specified by the tender b) On motor side 3 core ( From Switch & Starter to Motor ) to be specified by the tender (b) Providing & laying double loop earthing and copper plate 600 X 600 X 3mm thick electrode complete with material such as charcoal & common salt, G.I pipes, thimbles, nuts & bolts, digging of pits G.I wire & 25X3mm copper strips as per BIS : 3043-1987 latest with upto date ammendments for above motors & other electrical equipment. = 1 Job Note:- The strip size shall be 20x3 upto 18.5 KW,25x3 for 18.5 to 37 KW , 25x5 for 37 to 55 KW & 32x5 beyond 55 KW. (c) Supply & errection of floor power factor Shunt Capacitor conforming to BIS 2834-1986 latest with up to date ammendments BHEL / GEC / Machneil / Magger / Bajaj make to raise the prevailling power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered also including L & T / Standard / Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses ( Range to be specified by the tenderer.) = 1 No.
Providing and fixing of pressure transmitter with digital/analog outfit to be fixed in delivery line. = 1 No.
Providing and laying assembly of GI pipe considering site requirement and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevent BIS codes & capable of with standing the field test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers / reducers, flanges, rubber guskets 3 mm thick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. NOTE :-Actual laying to be done final drawings to be approved by the Engineer in charge. = 1 Job
Providing & Fixing of HMEI 7" Screen for displaying & controlling of Parameters= 1 No.
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions as per direction of the Engineer-in-charge. = 1 Job
Robin Mahajan
TECHPRO ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .