Loading…
Loading…
Updated dates
Tender Value
₹4.9 L
EMD Value
₹9,782
Closing Date
10 Jul 2026, 12:00 pm
Similar tender results from the same govt authority in the past 3 years.
ASSISTANT ENGINEER
ROOM NO 16 GROUND FLOOR PURTA BHAVAN DF BLOCK SECTOR I SALT LAKE KOLKATA 700 091
Emergent Construction falseceiling renovation and other allied S and P works of dismantled portions of Beliaghata campus with painting and patient party FRP Doors at ground floor and allied works during 2026 2027
2026_WBPWD_5015875_5
WBPWD/AE/NKHSD-I/NIeT-02/26-27
Open Tender
CIVIL WORKS
10 days
ID and BG Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,782
Yes
23 Jun 2026
23 Jun 2026
13 Jul 2026
24 Jun 2026
10 Jul 2026
24 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. | 0.2 | m2 | 19 | ₹3.8 | item code 1 |
| 2 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] | 0.2 | m2 | 171.73 | ₹34.35 | item code 2 |
| 3 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. b) 25 mm thick | 69.24 | m2 | 516.16 | ₹35,740.47 | item code 3 |
| 4 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. | 69.24 | m2 | 90 | ₹6,231.87 | item code 4 |
| 5 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). | 69.24 | m2 | 309 | ₹21,396.09 | item code 5 |
| 6 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge | 55 | m3 | 166 | ₹9,130 | item code 6 |
| 7 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth | 4.09 | m3 | 5,368.05 | ₹21,955.32 | item code 7 |
| 8 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor a) False Ceiling (with 4mm thick Pearl Designer Fibre | 91.7 | m2 | 705 | ₹64,647.09 | item code 8 |
| 9 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats ii) Solvent based interior grade Acrylic Primer | 71.61 | %m2 | 4,850 | ₹3,47,298.8 | item code 9 |
| 10 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) | 669.17 | m2 | 62 | ₹41,488.42 | item code 10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.