Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance | L1 | Accepted-Finance Single Bid |
Tender Value
₹4.0 L
EMD Value
₹7,950
Closing Date
25 Aug 2020, 11:00 amClosed
Executive Engineer
EE, CD, APWD, CampbellBay
Providing Siren for Disaster management including electrical works at Campbell Bay. SW Providing Siren, lightening arrestor, earthing and aviation obstruction light. 2nd Call
2020_APWD_647_1
NIT No. 03/EE/CD/CB/2020-21
Open Tender
Electrical Works
Item Rate
15 days
EE, CD, APWD, CampbellBay
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Payable To EE, CD, APWD, Campbell Bay
₹7,950
26 Aug 2020
3 Aug 2020
26 Aug 2020
3 Aug 2020
25 Aug 2020
3 Aug 2020
3 Aug 2020 - 21 Aug 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm
b) 7 x 6 sq. mm
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) a) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. a) Upto 35 sq. mm
Supplying and fixing 40 AMPS four pole,415 volts,two way centre off change over switch in the existing MCB DB complete with connections,testing and commissioning etc as required.
Supplying ofprewired LED tube lamp fitting 4',1X20 W similar to make Crompton Cat Ref: DMLN1LT8-16 with LED Tube lamp 20 Watt similar to make Crompton Retro LED T8 PC body, Cat Ref:LT8-20-865-2 etc as required or similar in make: Havels, Syska, Bajaj,Philips.
Supplying of LED bulkhead luminaries 1x8 Watt with IP65 protection, similar to Havells Rugby bulk head fitting in die cast aluminium housing & frosted glass Code:LHKL01160099 along with 7 Watt LED lamp or Similar in make Philips, Crompton, Syska.
Supplying of Double Walled Corrugated high density polythelene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS 14930 Part-I and II of the following sizes. a) 50 mm outer dia 38 mm inner dia nominal size
Laying of one number Double wall corrugated HDPE Pipe of following size on wall surface including fixing of snap-fit couplers as required. a) 50 mm outer dia (clamped with 1 mm thick GI clamps).
Laying of one number Double wall corrugated HDPE pipe of following size in the existing masonry open duct including fixing of snap fit couplers at joints as requried. a) 50 mm outer dia.
Laying of one number Double wall corrugated HDPE pipe directly in ground at a depth of 50 cm including excavation and refilling etc. as required but excluding sand cushioning and protective covering. a) Upto 90 mm outer dia.
Supplying of PVC insulated PVC sheathed (Heavy duty) armoured power cable with aluminium conductor for working voltage 1100 volts confirms to ISI standard of size 4 core x 16 sq.mm.
Supplying, installing, testing and commissioning of Horizontal double mounting three phase 400/440V 2800 RPM 50 Hz, AC electrically operated siren having audible range of 16 KM including 10Hp motor with Automatic Star-Delta starter similar to KHERAJ Model FD-1600 & Stater Havels Cat No.IHPASDMB or equivalent as per the direction of Engineer-in-charge.
Supplying and fixing of aviation obstruction light 36 Watt Similar to Bajaj Model :BGAV 302 LED Code:110731 IP 66 or equivalent and fixing it on GI Pipe 25 mm size 1.5 meter long and suitably fastening it on the existing structure or as per the direction of Engineer-in-charge.
Fabrication, installation, testing and commissioning of open type support structure for control panel board of size not less then 1200 x 1200 mm covered with 12mm marine ply for mounting of controls, made out of 5 mm 50 x 50 mm equal angles and duly painted with two coats of metal primer and two coats of synthic enamel. The support should be embedded in PCC 1:2:4 within a minimum depth of 0.3 mts. in ground and have a free space of 0.3m above floor level. Porceline cutouts 100 Amps each 03 Nos. and 01 No. 100 Amps Triple Pole Neutral switch disconnector with porcelein fuse unit must be fixed and making necessary interconnections with 10sq.mm copper cable & lugs of sizes etc. as required. Button holders 03 Nos. along with 0.5 Watt. LED lamps must be fixed and connected using 1.0Sq. mm. HRFR Copper wire for phase indicators etc. complete as required.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .