Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.0 LAccepted-AOC | L-1 | Accepted-AOC The work has been completed after Bank Guarantee. | |
| 2 | L-2₹17.6 L+₹2.5 L (16.7%)Rejected-Finance | L-2 | Rejected-Finance HIGH QUOTED RATE | |
| 3 | L-3₹19.1 L+₹4.1 L (27.2%)Rejected-Finance | L-3 | Rejected-Finance HIGH QUOTED RATE |
Tender Value
₹19.8 L
EMD Value
₹39,643
Closing Date
16 Jan 2020, 5:30 pmClosed
RAKESH KUMAR SAXENA
ZONE NO.14 BMC BHOPAL
Miscellaneous Electrical Work in Various Places at Zone No. 5,7,8 and 9 Bhopal.
2020_UAD_72754_1
2019204473
Open Tender
Electrical Works
Fixed-rate
30 days
ZONE NO.14 BMC BHOPAL
as per tender document
9 documents required · 9 mandatory
₹2,000
ONLINE
₹39,643
29 Oct 2021
2 Jan 2020
17 Jan 2020
2 Jan 2020
16 Jan 2020
2 Jan 2020
Amount
Miscellaneous Electrical Work in Various Places at Zone No. 5,7,8 and 9 Bhopal.
3000003705- DTR energy meter Supplying & installing totally enclosed 3 phase meter box of suitable pattern as per MPSEB requirement, fabricated with 16 SWG MS sheet duly painted with 2 coat of red oxide primer and 2 coat of synthetic enamel paint, suitable space to accommodate LPR type LT meter with CT's/HT trivector meter, providing required mounting plate/strip for energy meter, TTB & CTs, glass window for meter reading, incoming/outgoing cable, connection with proper size of lugs, earthing terminals etc. complete with all materials including providing, installing, testing/calibration from MPSEB (testing/calibration charges of meter and CTs will be bourn by agency) and connecting the following meter: CT operated 3 Ph. 4 Wire, 0.5 accuracy class LT DTR energy meter with LPR feature including GSM, modem etc. with 4 No. resin moulded 100/5 or 200/5 or 300/5 ratio LT CT as per MPHBSOR.
3000002029-Tension clamps(Dead end) Supplying & fixing of Aerial bunch cable accessories Tension clamps(Dead end) i/c required attachment for single core cable of approved make in Air with clamp, necessary material as per specification for required size.
3000001215-Clamp for Neutral Supply and installation of Clamp for Neutral
3000004236-3x50 Sq.mm, 1x16(St.Light), 1x35( Insula Supplying & drawing / laying of PVC insulated XLPE Aerial bunch power cable conductor H2/H4 grade Aluminium Solid/stranded confirming to IS-14255- 1995, Alu. Alloy insulated messenger 1100 volts grade cable of approved make in Air with necessary material as per specification of required size as mentioned below – 3x50 Sq.mm, 1x16(St.Light), 1x35( Insulated neutral messenger)
3000001218-Piercing connector type-II Supply and installation of Piercing connector type-II fo single phase/three phase.
3000001217-Piercing connector type-I Supply and installation of Piercing connector type-I for Single Phase/three phase
3000001213-Suspension clamp Supply and installation of Suspension Clamp
3000002471-Supply & fixing of spring loaded bus bar screwelss connector with enclosure of approved make including required clamps & nut bolts connections and testing as per specification to complete the job Three phase (a)3ph,1in +8 out
3000002030-CT PT Unit 300-150/5Amp Supplying, installation, testing and commissioning of oil immersed, .5 accuracy class, 50 Hz CT PT combined unit complete with all other materials as required including testing / calibration charges of Electricity board as required. 11 KV/110 V, 3 phase 4 wire CT PT combined unit, 300-150/5Amp. or 200- 100/5Amp. or 100-50/5 Amp. CT ratio
3000008849-500 KVA (33/0.433 KV) distribution trans Shifiting, erection, & commissioning of of 100/ 200 / 315 / 500 KVA (33/0.433 KV) distribution transformer on existing structure including Bi-metallic clamp, ACSR/AAAC Conductor i/c colour code sleeve, for connection from H.T. Line to transformer as required as per specification. as per MPPWDD SOR
3000009033-3x25 Sq.mm, 1x16(St.Light), 1x25 Supplying & drawing / laying of PVC insulated XLPE Aerial bunch power cable conductor H2/H4 grade Aluminium Solid/stranded confirming to IS-14255- 1995, Alu. Alloy insulated messenger 1100 volts grade cable of approved make in Air with necessary material as per specification of required size as mentioned below – Single Core cable 3x25 Sq.mm, 1x16(St.Light), 1x25( Insulated neutral messenger), As per MPPWD SOR
3000008630-AB cable 3x95 Sq.mm, 1x16(St.Light), 1x5 Supplying & drawing / laying of PVC insulated XLPE Aerial bunch power cable conductor H2/H4 grade Aluminium Solid/stranded confirming to IS- 14255- 1995, Alu. Alloy insulated messenger 1100 volts grade cable of approved make in Air with necessary material as per specification of required size as mentioned below – Single Core cable( Insulated neutral messenger) 3x95 Sq.mm, 1x16(St.Light), 1x50( Insulated neutral messenger)ine aggregates and eight coarse aggregates) using
1000004967-150 watt LED Supply & installation commissioning of LED street light fittings on existing street light poles complete with required material (street light network) with 01 year guarantee & 04 years CMC (comprehesive maintenance contract) Under BMC area LIMIT)(a) 150 watt as per NIT specification.
3000009052-200 Watt LED Supply & installation commissioning of LED street light fittings on existing street light poles complete with required material (street light network) with 01 year guarantee & 04 years CMC (comprehesive maintenance contract) Under BMC area LIMIT) (a) 200 watt as per NIT specification.
Bidder Name
Amount
JAGDAMBA FOUNDATION
RIGHTWAYS CONSTRUCTIONS
ALOK ENTERPRISES
JAGDAMBA FOUNDATION
ALOK ENTERPRISES
JAGDAMBA FOUNDATION
ALOK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .