Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC C O RANJIT ELECTRICAL KEATING ROAD SHILLONG 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | L1 | Accepted-AOC AOC PLACED ON L1 BIDDER WITH CONTRACT AGREEMENT NO GE/SHL/29 OF 2024-2025 | |
| 2 | L2₹49.0 L+₹1.6 L (3.26%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 3 | L3₹49.4 L+₹1.9 L (3.99%)Rejected-Finance 155 KARNAL NEW GRAIN MARKET KARNAL KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | L3 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 4 | L4₹49.7 L+₹2.2 L (4.57%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 5 | L5₹50.5 L+₹3.1 L (6.44%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
20 Jun 2024, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG PIN 793002
REPAIR LEAKAGE / SEEPAGE SUNKEN FLOOR AND CONNECTED B/R WORKS FOR REPAIR TO TOILETS AT OTM ACCN AND MD ACCN OF ARC 11 WEU MDC MES OF HAPPY VALLEY AND REPAIR/REPLACEMENT OF SEWAGE SYSTEM INCLUDING CLEANING OF SEWAGE LINES MANHOLES SEPTIC TANKS SOAK
2024_MES_657097_1
GE/SHL/TOKEN-25 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE SHILLONG
₹99,000
15 Jul 2024
31 May 2024
21 Jun 2024
31 May 2024
20 Jun 2024
13 Jun 2024
Amount
Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in hard/dense soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated soils to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 200 mm bore grade ‘A’, laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50m complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore grade ‘A’, laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50m complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 100 mm bore grade ‘A’, laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50m complete all as specified and as directed.
M&L for Reinforced concrete pipes, 150 mm bore, class NP2, grade ‘A’, laid and jointed complete with collars laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggrete) as in concrete bed to drain pipes, including forming cradles after they are laid & tested including demolition and breaking up old drain pipes (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50mtrcomplete all as specified and as directed.
Cleaning of sewage lines of 100/150/200 mm bore pipe using split Bamboo and gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage lines through manhole/ gully trap till clear flow of sewage is observed complete all as directed.
Taking out and removing sludge water/waste materials/foreign materials from septic tank of any size and burying the entire sludge under ground in the pit of suitable size and covering the pit with earth or earth mixed rubbish and removing surplus soil to a distance n.exc 50 m including all necessary earth work complete all as directed.
Cleaning of blocked water closet by flushing with water and cleaning of soil pipe upto first manhole, cleaning WC Pan/Floor trap/Nahani Trap of bathroom, kitchen/urinalss and flushing cistern with water complete all as directed.
Cleaning of manholes of depth n exc 1m using spades or bucket and taking out sludge, disposing off aside and putting earth on it, cleaning and washing out the manhole with water to completely clear the sludge and ensure the sludge is drain out completely all as directed.
Ditto all as per item No 12 here-in-before but depth of manhole exc 1m but n.exc 2m.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with clamps or laid in floors including taking taking down old unserviceable pipes complete all as specified and directed.
Ditto all as per item No 14 here-in-before but for 75mm bore PVC (SWR) pipes
S&F in repairs 110mm bore PVC (SWR) branch piece single (Y) equal or unequal complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) branch piece single (Y) equal or unequal, with access door complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends, any radius with access door complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends, any radius with access door complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) junction single (single T) equal or unequal with acess door complete all as specified and directed..
S&F in repairs 75mm bore PVC (SWR) junction single (single T) equal or unequal with acess door complete all as specified and directed..
S&F in repairs 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) reducers complete all as specified and directed.
S&F in repairs 180mm size PVC gutter , Half Round, fixed with clamps complete all as specified and directed.
S&F in repairs 180mm size Joint Bracket (with 2 clamps) for PVC pipes (half round) complete all as specified and directed.
S&F in repairs 180mm size Support Bracket for PVC pipes (half round) complete all as specified and directed.
S&F in repairs 180mm size Running Outlet (with 2 clamps) for PVC pipes (half round) complete all as specified and directed.
S&F in repairs 180mm size Stop End Outlet (with 1 clamp) for PVC pipes (half round) complete all as specified and directed.
S&F in repairs PVC Reducer, 180mmx110mm complete all as specified and directed.
S&F in repairs 150 x 100 mm size Salt-glazed stoneware gully traps, square or round mouthed, type 'P' complete all as specified & directed.
S & F in repairs 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specified and as directed.
Demolition of cement concrete (reinforced) as in cover slabs, RCC water tank etc. of any description and in any position not otherwise provided for and Including removal of debries out side MoD land complete all as directed.
Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground lever) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:6 complete all as specified and as directed..
M&L for PCC (1:4:8), type D2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L 75mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in floors of septic tank finished even and smooth using extra cement complete as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection layed in bays n exc 2m, finished even and smooth without using extra cement complete as specified and directed.
M&L 75mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in path, finished even and smooth without using extra cement complete as specified and directed.
M&L for PCC (1:3:6), type C2 using 40mm graded crushed stone aggregate in surface channels and drains etc. finishing surface even and smooth without using extra cement and including necessary form work complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L for PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in benching & coping incl necessary form work moulds all as specified and as directed.
M&L for PCC (1:5:10), type E2 using 40 mm graded crushed stone aggregate as in sub base to WC complete all as specified and directed.
Removal of plant/vegetation/bushes growth etc. from roof or parapet of building including complete removal of root and making good disturbed surface with cement mortar 1:3 mixed liquid waterproofing compound as per manufacturer's instruction complete all as specified and directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening existing concrete slab by picking, sweeping clean and washing down with water to remove dust etc. (ii) Rendering 15 mm thick in CM 1:4 Screed bed or bedding layer for laying as in roof slab with mixing of WPC and surface finished fair and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) Laying APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
M&L for water proofing treatment to sunken portion of RCC slab with the following courses of treatment/specification :- (i) Rendering 15 mm thick in CM 1:4 Screed bed or bedding layer for laying as in sunken portion with mixing of WPC and surface finished fair and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (ii) Preparation of plastered roof surface and applying one coat of cold bituminous primer @ 0.25 ltr /Sqm conforming to IS:3384-1986. (iii)Laying APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm), applied by torch application over bituminous primer as specified. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. Note:-The work of sunken portion treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. Contractor shall submit documentary evidence on support of applicator engaged.
M&L for precast cement concrete block masonary with solid blocks, exc 10cm in width or girth, made out of PCC (1:3:6) type C1 using 20mm graded crushed stone aggregate, and set in cement mortar (1:6) complete including demolition of exisitng precast cement concrete block walling in any position and removal of debries out side MoD land all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish from site of work complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick or concrete surface, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick or concrete surfaceand, finished even and smooth without using extra cement including taking down cement plaster in cement mortar, raking out joints, hacking for key, scrubbing down with water etc. and removal of debries out side MD land all specified and directed.
M&L 15 mm thick rendering in CM 1:4 in two layers, first 10 mm thick base layer & finishing 5 mm thick with approved water proofing compound @ 3% by the weight of cement or as per manufacturer's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately here-in-after.
M&L for rendering 5 mm thick in CM 1:3 on fair concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and as directed.
Supply on integral water proofing compound.
M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats creosote oil complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls including cornices, pilasters etc. and applying two coats of white wash complete all as specified and directed
Taking down chowkhat with shutter (without taking off shutter from the frame) n exc 1.5 sqm each complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed.
S&F 200mm size Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore GI tubing, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore GI tubing, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Refixing 15mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Refixing 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Cutting chases, pinning in concrete block work making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth. complete all as specified and directed.
S&F in repairs 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm dia Bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs 15mm dia stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 15mm dia Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm bore brass CP WHB mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm bore brass CP sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repairs Stop valve of 15mm dia in PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 gms) complete all as specified and directed.
S&F in repair bib tap of 15mm dia in PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 gms) complete all as specified and directed.
S&F in repairs Vitreous china squatting pan 'Orissa' Pattern of size 580x 440 mm white with 110mm bore PVC ‘P’ or ‘S’ trap , front or back inlet including placing in position in floor and embedded in cushion of PCC 1:5:10 type E2 using 40 mm graded crushed stone aggregate and finishing the top surfaces to match with the existing flooring complete all as specified and directed.
S&F in repairs Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repairs to 600mm long PVC Waste pipe for WHB/urinals/Sink complete all as specified and as directed.
S&F in repairs PVC flush pipe of low or high density 32mm dia including jointing and fixing complete.
S & F in repair PVC low level flushing cistern 10 litre capacity, white, valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle, 32 mm dia PVC flush pipe of suitable length and making all connection and making good disturbed surface complete all as specified and directed.
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S & F in repairs Vitreous china wash hand basin, white, flat back of size 550 mm x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32 mm dia, PVC flexible waste pipe of adequate length and dia and PVC connection 15mm size 450 mm length with PTMT nuts, complete all as specified and as directed.
S&F in repairs sinks made of stainless steel, 1mm thick, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm & bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs kitchen sink with drainage board overall size 915x460 mm & bowl size 410mmx360mmx160 mm, made of stainless steel 1mm thick with plug washers and wastes including bedding in CM to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed.
S & F in repairs Stainless steel kitchen plate rack of size 36'' X 36 '' X 10'' made out of stainless steel sheet of 1.00 mm with all accessories including taking down old unservicable one etc complete all as specified and directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, D type, 600mm long between flanges complete all as specified and directed.
S&F in repairs chromium plated soap dish holder complete all as specified and directed.
S&F in repairs corner shelf set of 03 nos PVC with bracket complete all as specified and directed
S&F in repairs grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S& for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F 500 ltrs capacity rotational moulded HDPE water storage tank ,double layer ,ISI marked (cylindrical vertical type with closed top) placing in position including 15mm bore float valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed including dismantling old unserviceable water tank complete all as specified and directed.
S&F 100 ltrs capacity rotational moulded HDPE water storage tank ,double layer ,ISI marked (cylindrical vertical type with closed top) placing in position including 15mm bore float valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed including dismantling old unserviceable water tank complete all as specified and directed.
S&F in repairs PVC Tank cover for 1000 ltrs/500 Ltrs with locking arrangement all as specified and directed
S&F in repairs 20 mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 m m - 210 gms ) complete all as specified and directed.
Cleaning of service water tank of capacity upto 500ltr RCC/PVC and connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc. or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out water from tank and washing internally by using bleaching powder, again draining out the water in the tank and applying single coat of lime washing on RCC tanks ( Rate includes cost of writing date of cleaning with paint after removing the old date by painting including disconnecting existing tanks,setting aside (or lowering if reqiured) for repairs cleaning etc. and hoisting if required reconnecting and re-fixing in same position) complete all as specified and directed
Cleaning of service water tank of capacity exc 500 Ltrs and upto 1000 Ltrs RCC/PVC and connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc. or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out water from tank and washing internally by using bleaching powder, again draining out the water in the tank and applying single coat of lime washing on RCC tanks ( Rate includes cost of writing date of cleaning with paint after removing the old date by painting including disconnecting existing tanks,setting aside (or lowering if reqiured) for repairs cleaning etc. and hoisting if required reconnecting and re-fixing in same position) complete all as specified and directed
M/S SAMAL CONSTRUCTION
N.K.TRADING COMPANY
Ms Amrik Singh Bahra
M/s Chandan Kumar Thakur
M/S U.K ENTERPRISE
S K Construction
M/S. Ranjit Kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .