| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.1 LAccepted-Finance | 1 | Accepted-Finance Accepted being L1 | |
| 2 | 2₹42.5 L+₹9.3 L (28.1%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹45.1 L+₹11.9 L (36.0%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹47.6 L+₹14.4 L (43.5%)Rejected-Finance HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹53.0 L+₹19.8 L (59.8%)Rejected-Finance | 5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹46.1 L
EMD Value
₹92,500
Closing Date
24 Dec 2024, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT
SPL REPAIR REPLACEMENT OF LT XLPE UG CABLES LT PANELS AND STREET LIGHT AT CHURCH ROAD OFFRS MD ACCN QTR NO P 02 TO 21 AND CONNECTED ALLIED WORKS AREA OF AGE SLDC UNDER GE U ES DELHI CANTT10
2024_MES_685582_1
GE ELECT/D-82/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹92,500
Yes
2 Jan 2025
26 Nov 2024
26 Dec 2024
26 Nov 2024
24 Dec 2024
10 Dec 2024
Amount
M&L for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
M&L for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
M&L for removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.
S&F of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 complete all as specified and directed by Engineer- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge. Cables of the following sizes:- Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
35 Sq mm 3.5 core.
95 Sq mm 3.5 core.
120 Sq mm 3.5 core.
185 Sq mm 3.5 core.
S&F of Junction box of IP67 (as per IEC 60529) Thermoplastic PC- GFS Polycarbonate Weatherproof, UV resistant due to solar radiation, Rainwater proof, temperature resistant, Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C (as per IEC 60695 – 2 – 11) Junction Box having size (205 x 255 x 112 mm) size on Pole with 1No. 10 Amp C Curve series, 10kA SP MCB i/c supply with pole mounting kit for clamping the box on pole, earthling the body connection, inter- connection, suitable terminal blocks, glands, locknut etc. complete set as reqd. for Pole lighting complete all as specified and directed by Engineer- in- Charge.
S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.
S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.
S&F of LED Flood lights 50 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.
S&F of LED Flood lights 120 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.
S&F of LED Flood lights 200 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.
S&F of 90 Watt LED street light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge. Make Crompton Model No LFLN-120-CDL/60-M
M&L for GI Tubes of size 50 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and directed by Engineer- in- Charge.
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Indoor type with copper bus bar of capacity 200A, factory made, CPRI approved,e floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with bproper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and elarth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 100 Amps 3 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 06 Pcs) (d) RYB Indicating lamp (e) Digital laVoltmeter and ammeter of suitable rating (f) set of ibtCT of ratio - 100/05 Amps Outgoing. (a) Suitable hole in bus bar for out going cable connection including suitable size nut bolt and fastener complete all as specified and directed.
Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 400A, factory made, CPRI approved,e floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with bproper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and elarth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 250 Amps 3 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 06 Pcs) (d) RYB Indicating lamp (e) Digital laVoltmeter and ammeter of suitable rating (f) set of ibtCT of ratio - 250/05 Amps Outgoing. (a) Suitable hole in bus bar for out going cable connection including suitable size nut bolt and fastener complete all as specified and directed by Engineer- in- Charge.
Supply & installation of steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate, PCC coping, GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and complete all as specified and directed by Engineer- in- Charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings. The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside.
M&L for boring of holes under road, pavement, hard standing by trenchless technology including 150 mm dia HDPE pipe suitable for 0.6 mpa working pressure complete all as specified and directed by Engineer- in- Charge. Note :- The quoted rate shall deemed to be included of taking permission from concerned authority like Army Signal and other utility authority and any damage done during execution of work and the same will be repaired/replaced by the Contractor.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 3 of MES SSR part-I (1991).
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. (iv) Energy meter is not included in the present scope of work and shall be shifted from Old LT Panel to New LT Panel. The rate for shifting is also deemed to be included in the quoted rates.
S&F of 10 W twister IP 65 Rated LED Bollard with robust design and efficient light distribution (garden lights) Make Crompton Twister Cat No LBLTW-10-CDL and pole (length 1.5 to 2ft) base cover aestetocally designed decorative pole base cover, enhancing the apearance of the pole complete all as specified and directd by Engineer-in-Charge. Note- The cost of excavation and PCC 1:3:6, type C-1 for foundation of size (20x20x20cm) required for post top light pole is deemed to be included in the quoted rate.
S&F of Decorative Post top lantern 40 Watt indirect light IP_65 protection resistant to impact and corrosion, glare free and better uniformity complete all as specified and directd by Engineer-in-Charge. Make : Crompton MAPLE Cat No LPTO-40-CDL
S&F of Arcus linear wall washer, extruded aluminium, powder coated IP66 linear wall washer, to accentuate the artwork on entrances and walls complete all as specified and directd by Engineer-in-Charge. Make : Crompton Cat no :- LF01-361-030-CC-10 (40W)
S&F of Colour changing solutions, extruded aluminium, powder coated IP66 linear wall washer, to accentuate the artwork on entrances and walls complete all as specified and directd by Engineer-in-Charge. Make : Crompton Cat no :- LF01-361-030-CC-10 (40W)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3190777)
mayur enterprises (BID ID -3191335)
S K ENGINEERS AND CONTRACTOR (BID ID -3197001)
Rajindera Enterprises (BID ID -3191661)
Vijay Electricals (BID ID -3191162)
Ridhi engineers and builders (BID ID -3190632)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .