Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.3 L
Closing Date
10 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TELECOM
14 conditions · 2 needing a document upload
For Standard Financial Criteria, please refer Para No.1.1.2 of Chapter-I of Tender Document [Also refer to the Para 10.2 of the Tender Form (Second Sheet) of GCC April-2022] and Advance Correction Slip no.1 issued by Railway Board vide letter no.2022/CE-I/CT/GCC-2022/Policy dated 14.07.2022, same is re-iterated below: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC April-2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
For Standard Technical Criteria, please refer Para No.1.1.1 of Chapter-I of Tender Document [Also refer to the Para 10.1 of the Tender Form (Second Sheet) of GCC April-2022].
Defination of Similar Work :- Similar work shall mean any work as a whole or having component of supply, installation, testing and commissioning of Passenger Amenities items involving one or more of items furnished below: i)Train Indication system for Railway Platforms. ii)Coach Guidance system for Railway Platforms. iii)PC based announcement system for Railway Platforms. iv)GPS and GSM/ GPRS based display and publication systems in coaches. v)GPS based digital and / or analog clock systems for Railway Platforms vi)Public address system for inside coaches of Passenger Trains.
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please refer to the attached documents - "Tender Document" and "GCC April 2022 with all ACS".
Provision of train indicator, Coach indicator and other passenger amenities in connection with the work of "Provision of minimum essential amenities and Divyangjan Facilities at Valivade, Bhilawadi and Rukadi stations of Pune division".
CR-PA-SNT-WKS-T-2026-04~CR
CR-PA-SNT-WKS-T-2026-04
Open
Works - General
6 Months
Pune, Maharashtra
₹0
₹2.3 L
10 Jul 2026
10 Jun 2026
26 Jun 2026
164 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,13,10,363.02 | ||
| — | 111.00 | — | — | ||
| — | — | — | 13,90,219.5 | ||
| of Double Faced Ver 1.0 or latest. (Inspection | :- Supply | — | — | ||
| — | — | — | Boards | ||
| — | — | — | as | ||
| — | 93.00 | — | — | ||
| Installation & commissioning of LED based double faced display board in open area, includes supply & installation of 100mm GI pipe, erection & all material required etc as per specifications using OFC and ring network. (Inspection by Consignee) | — | — | — | 5,35,856.7 | |
| — | 18.00 | — | — | ||
| Installation & commissioning of LED based double faced display board in covered area with all type of hardware required with proper size clamps & fixtures as approved by Railways using OFC and ring network. (Inspection by Consignee) | — | — | — | 44,984.52 | |
| — | 4.00 | — | — | ||
| Supply of LED based Single faced At a Glance display board as per RDSO's Specification No.RDSO/SPN/TC/108/2019, Ver 1.0 or latest. Suitable clamping arrangement and all consumable materials including steel frame to be supplied by the contractor. (Inspection by RDSO) | — | — | — | 4,32,073.12 | |
| — | 4.00 | — | — | ||
| Installation and commissioning of LED based At a glance display board as per instruction of site incharge. All fitting materials are to be supplied by the contracor. (Inspection by Consignee) | — | — | — | 43,040.72 | |
| — | 2.00 | — | — | ||
| Supply of Single line double faced Train Arrival/Departure Display Boards as per RDSO specification RDSO/SPN/TC/108/2019Ver 1.0 or latest. (Inspection by RDSO) | — | — | — | 3,35,995.18 | |
| — | 2.00 | — | — | ||
| "Installation & commissioning of Single line double faced Train Arrival/Departure Display board. This includes all required accessories required including hanging structure for fixing arrangements to commissioning the item. (Inspection by Consignee) " | — | — | — | 20,826.14 | |
| — | 3.00 | — | — | ||
| Supply and installation of 55 inch 4K ultra HD smart LED TV display unit as per specification attached as annexure. (Inspection by Consignee) | — | — | — | 1,76,986.71 | |
| — | 2.00 | — | — | ||
| Supply of Central Data Controller (CDC) units with central Data Switch (CDS) alongwith all software vide spec no:-RDSO/SPN/TC/108/ 2019, Ver 1.0 or latest. (Inspection by RDSO) | — | — | — | 8,70,532.94 | |
| — | 2.00 | — | — | ||
| Installation & commissioning of Central Data Controller (CDC) units with central Data Switch (CDS) alongwith all software vide spec no:-RDSO/SPN/TC/108/2019Ver 1.0 or latest using OFC and ring network. (Inspection by Consignee) | — | — | — | 13,189.9 | |
| — | 5.00 | — | — | ||
| Supply of Platform Data Controller (PDC) as per RDSO/SPN/TC/108/ 2019 Ver 1.0 or latest. (Inspection by RDSO) | — | — | — | 1,44,047.5 | |
| — | 5.00 | — | — | ||
| Installation & commissioning of Platform Data Controller (PDC) as per RDSO/SPN/ TC/108/ 2019 Ver 1.0 or latest using OFC and ring network. (Inspection by Consignee) | — | — | — | 13,110.4 | |
| — | 3.00 | — | — | ||
| Supply of maintenance console as per specification attached as annexure. (Inspection by Consignee) | — | — | — | 1,75,557.3 | |
| — | 3700.00 | — | — | ||
| Supply of power cable 2.5 Sqmm 3 core as per RDSO's Specification No. RDSO/SPN/TC/108/ 2019, Ver 1.0 or latest. (Inspection by Consignee) | — | — | — | 3,05,657 | |
| — | 3965.00 | — | — | ||
| Supply of STP (Shielded Twisted Pair) CAT-6 cable with braiding for networking from Lucent or Molex or DAX or Finolex or Polycab make (1 Box = 305 Mtrs). (Inspection by Consignee) | — | — | — | 1,51,383.7 | |
| — | 7665.00 | — | — | ||
| Laying & drawing of communication/ power/ data cable through 1" PVC conduit pipe. This includes fixing of pipe with all accessories as required as per site condition. (Inspection by Consignee) | — | — | — | 2,24,201.25 | |
| — | 700.00 | — | — | ||
| Supply of conduit pipe size 25mm dia 2 mm thickness and 3 mtrs standard length with ISI mark from Astral, Supreme or Garware make. (Inspection by Consignee) | — | — | — | 17,283 | |
| — | 700.00 | — | — | ||
| Fixing of PVC conduit pipe on wall, bridges, platform shed complete with 'U' clamps and necessary fixture screws etc. as per route given by site engineer of Railways. (Inspection by Consignee) | — | — | — | 3,675 | |
| — | 800.00 | — | — | ||
| Removal of paver blocks/ tiles and Cutting of trench across on platform for a depth of 15 cm & width of 15 cm after removal of paver blocks /tiles with marble cutting machine & filling the trench after laying the cables & restoring the surface with original tiles/ paver blocks. (Inspection by Consignee) | — | — | — | 50,728 | |
| — | 5000.00 | — | — | ||
| Supply of HDPE duct 50mm dia, inner dia 42mm and wall thickness 4mm, permanently lubricated etc. supplied from TEC approved sources. (Inspection by Consignee) | — | — | — | 2,13,300 | |
| — | 5000.00 | — | — | ||
| Laying & fixing of HDPE duct for protection of cable in trenches or roof wall etc as per route given by site Engineer of Railways. (Inspection by Consignee). | — | — | — | 30,900 | |
| — | 1.00 | — | — | ||
| Supply, installation and commissioning of On Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Rating of UPS:5.0 KVA, Indicative Backup time: 60 Minutes. This includes external battery as required to cater the back uptime. Make: Microtek, Luminous, Champion. (Inspection by Consignee) | — | — | — | 63,567.39 | |
| — | 2.00 | — | — | ||
| Supply of On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor mounted type with SNMP module. Rating of UPS 3.0 KVA, indicative Back-up time :120 minutes, This includes external battery as required to cater the back uptime. Make:- APC, Microtek, Luminous.Champion. (Inspection by Consignee) | — | — | — | 1,81,005.18 | |
| — | 1.00 | — | — | ||
| Supply of High power two tone PA Amplifier capable of delivering 200 watts output power from each zone total 400 watts of Model TZA - 4000EM of make Phillips or Yamaha or Bosch make only. (Inspection by Consignee). | — | — | — | 14,652.71 | |
| — | 21.00 | — | — | ||
| Supply of column speaker Ahuja make AC 20T or similar model of Philips, Bosch. (Inspection by Consignee). | — | — | — | 26,483.52 | |
| — | 18.00 | — | — | ||
| Supply of Reflex horn speakers Ahuja make model UHC 30XT or similar model of Hi- Tune, Bosch. (Inspection by Consignee). | — | — | — | 22,700.16 | |
| — | 11.00 | — | — | ||
| Fixing of column & horn type speakers in covered area with all type of hardware required with proper size clamps & fixtures etc. as approved by Railways. As per instruction of Engineer at site. (Inspection by Consignee). | — | — | — | 5,642.45 | |
| — | 28.00 | — | — | ||
| Installation of column & horn type speakers where covered platform is not available. The same is to be fixed on 3'' GI pipe low grade IS specification no. 1239 of 1992 with latest amendment. Fixing of equipments with hood includes supply of bracket for housing speaker, GI pipe and cement etc. with complete erecting and installation of GI pipe for Horn speakers. As per instruction of Engineer at site. (Inspection by Consignee). | — | — | — | 1,02,420.92 | |
| — | 2650.00 | — | — | ||
| Supply of twin core shielded cable two standard colour, 2 cores 24 strand copper conductors, each strand of 0.20 mm, (24/0.20 mm) as per IS Specification No.694/1900, PVC insulated copper conductor in over all PVC Jacket from reputed make like Delton or Finolex or Asian or network or Lucent or Polycab. (Inspection by Consignee) | — | — | — | 54,722.5 | |
| — | 2650.00 | — | — | ||
| Laying & drawing of PA cable through 1" PVC conduit pipe along the walls/ girder/ bridges/ platform shed etc. as per the approved plan and instruction of site engineer of Railways. (Inspection by Consignee). | — | — | — | 10,123 | |
| — | 1500.00 | — | — | ||
| Supply of Armoured Optical Fiber Cable, 12 Core, Single mode armoured. Make: Polycab, FINOLEX or similar. (Inspection by Consignee) | — | — | — | 52,065 | |
| — | 10.00 | — | — | ||
| Supply of 12 port LIU, 19-inch rack mountable as per following specification: a) It should have 12 SP type ports for termination of SM optical fibres. b) It should be rack mountable with 1U height. c)It should be equipped with front managed saddle for jumper/patch cord management. d) It should have 12 SC termination. e) It should be equipped with adequate nos. of splicing trays to splice 12 fibres. f) It should have proper rubber grommet for cable protection and to minimize dust build up. g) It should be fully loaded with all the accessories for splicing and termination of fibres. h) It shall be of reputed make like D-Link or 3M or Digilink or Molex make or similar. (Inspection by Consignee) | — | — | — | 60,374.7 | |
| — | 10.00 | — | — | ||
| Installation & commissioning of 12 port LIU with all accessories and shall be used for terminations of optical fibers into the splice trays supplied with it, it shall be installed inside the 19 inch rack using all required fixing/ installation material like nuts, bolts, screws and cable ties etc. as per requirement. The splice trays shall be placed and secured into the LIU after splicing. The SC terminations shall be fixed and secured after splicing of the pigtails into the LIU. It shall be ensured that the movement of the trays is easy and free of any obstructions. (Inspection by Consignee) | — | — | — | 8,901.7 | |
| — | 5.00 | — | — | ||
| Supply and installation of wall mounting 9U 19'' deep rack make VALRACK or similar complete with assembly. (Inspection by consignee) | — | — | — | 24,402 | |
| — | 1.00 | — | — | ||
| Supply & installation of 24U rack with 19 inch standard dimension, front glass door with lock and two key, with rack fixing multipoint AC power strip, cable organiser with wall fixing screws. Make: TrippLite, APC, Rackom or similar. (Inspection by Consignee) | — | — | — | 22,507.11 | |
| — | 300.00 | — | — | ||
| Supply of RJ-45 Jack modules (male) Suitable for UTP Cat_6/Cat_5 cable systems. (Inspection by consignee) | — | — | — | 1,728 | |
| — | 1.50 | — | — | ||
| Drawing of Optical Fiber Cable and any other cable in already laid HDPE pipe/FRP tray. (Inspection by Consignee). | — | — | — | 17,335.95 | |
| — | 96.00 | — | — | ||
| Splicing/ dropping/ termination of each fiber/pigtail in LIU/ IO box/ terminal joint through fusion splicing for termination of OFC cables.The fibers terminated shall be tested and test report(hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/ tags, as per following specification: i)The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii)The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the already fixed LIU. iii) Each of the fibre shall be spliced with a pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber/ pigtail shall be properly marked with necessary ferrules/ tags. vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties.vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers. viii)All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records. (Inspection by Consignee) | — | — | — | 12,232.32 | |
| — | 30.00 | — | — | ||
| Supply of fiber optic patching cord LC-FC/FC-FC/LC SC as per site requirement. Make of 3M or Sterlite or Finolex or Raychem or similar. (Inspection by Consignee) | — | — | — | 21,594 | |
| — | 6.00 | — | — | ||
| Supply of Media converters with one Fiber port (SC connector) and four Ethernet ports, supporting port isolation and with built in AC Power supply. Make: RAD, ANDA Telecom, ZYXEL. (Inspection by Consignee) | — | — | — | 28,849.08 | |
| — | 1000.00 | — | — | ||
| Supply of hot dipped galvanised perforated type cable tray of size 150 x 75 mm made of 16 SWG(1.6 mm thick) GI sheet necessary coupler plates & fixing material. (Inspection by Consignee) | — | — | — | 3,51,030 | |
| — | 1000.00 | — | — | ||
| Fixing & erection of hot dipped galvanised perforated type cable tray with necessary fixtures & accessories as required at site for execution of work. Work as per instruction of incharge at site. (Inspection by Consignee) | — | — | — | 75,380 | |
| — | 30.00 | — | — | ||
| Supply of RJ-45 UTP patch cord of 7 feet length from Krone or Trendnet or D-link make or similar. (Inspection by Consignee) | — | — | — | 1,393.5 | |
| — | 6.00 | — | — | ||
| Supply of 6 Way Power Trip Spike Guard Universal Socket with No. of Sockets - 5 Pin 6 Amp.: 4 nos, No. of 6 Amp Switches: 3 nos, No. of cores in the cable: 3 nos (2.5 sq.mm), Length of cable with Extension Box: 3 Mtr, ISI Market Socket, Input Plug Rating: 6 Amp, No. of pin in the input plug: 3nos, Power on indicator available. Make: Anchor or Philips or Schinder or similar. (Inspection by Consignee). | — | — | — | 2,429.04 | |
| — | 645.00 | — | — | ||
| "Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. (Inspection by Consignee) " | — | — | — | 2,21,480.1 | |
| — | 90.00 | — | — | ||
| Excavation of cable trench as per cable route plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/ bricks, clearing of route, bushes etc.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made. (Inspection by Consignee). | — | — | — | 52,144.2 | |
| — | 110.00 | — | — | ||
| "Wherever depth of 0.5 m cable trench is not feasible cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. (Inspection by Consignee)" | — | — | — | 5,73,586.2 | |
| — | 30.00 | — | — | ||
| Supply of Cat-6 patch cord 1 Mtr from D-link or DAX or Krone or Finolex make. (Inspection by Consignee) | — | — | — | 1,511.1 | |
| — | 350.00 | — | — | ||
| Supply of PVC casing & capping of size 25mm x 25mm and 2mm thickness piece with all accessories like jont, bends etc of Precision, Garware make or similar standard make. (Inspection by Consignee). | — | — | — | 17,647 | |
| — | 150.00 | — | — | ||
| Supply of PVC channel of size 50x50 mm with all accessories like joint, bends etc of precision, Garware make or similar standard make. (Inspection by Consignee). | — | — | — | 12,409.5 | |
| — | 500.00 | — | — | ||
| Fixing of PVC casing & caping or conduit on wall etc. with suitable fasteners as per route given by and as per instruction of site engineer of Rly. This inclues breaking up of wall for cabling & painting it to original level & laying of cables. (Inspection by Consignee). | — | — | — | 1,805 | |
| — | 102.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 with sockets and fittings. (Inspection by Consignee) | — | — | — | 1,09,286.88 | |
| — | 102.00 | — | — | ||
| Laying of GI pipes in on bridges/culverts/concrete drawin/mountain ridges etc. with suitable GI bend shall be provided where there is turning of pipe as per the instruction of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per the instruction of the site engineer 10mm dia. (Inspection by Consignee) | — | — | — | 13,961.76 | |
| — | 5.00 | — | — | ||
| Supply and installation of 24 Port POE switch with 4 SFP port 2 Gigabit SFP module loaded out of 4 SFP) manageable 24 port 10/100/1000 Mbps layer 2 switches with minimum 2 SFP port loaded with fiber module of 1000LX SMF in the blank SFP slot and POE functionality. IP multicast snopping and data driven IGMP support as per RDSO specification no. RDSO/SPN/TC/83 2017 Rev.1 (with latest amendments/ revision) and other specs (switch fabric bandwidth of 12 Gbps or more, frame forwarding rate of 9 Mbps or more.) (Inspection by Consignee) | — | — | — | 2,14,241.75 | |
| — | 6.00 | — | — | ||
| Supply of chair for sectional JE/SSE with cushioned seat and back. Make: Godrej model Bravo Mid Back or similar model of Nilkamal or Durian. (Inspection by Consignee) | — | — | — | 44,928.96 | |
| — | 3.00 | — | — | ||
| Supply of table for sectional JE/SSE make Godrej model T104/T111 or similar model of Durian or Urban Ladder. (Inspection by Consignee) | — | — | — | 26,568.78 | |
| — | 3.00 | — | — | ||
| Supply of Steel cupboard (plain storewel) for SSE/JE store of size 6'x3'. Make Godrej or Nilkamal or Pepperfry. (Inspection by Consignee) | — | — | — | 35,409.39 | |
| — | 2.00 | — | — | ||
| "Maintenance free earth as per RDSO/SPN/197/2008 or latest consisting of: (1) Copper bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min 250 micron & UL listed & marked-01 No. (2) Earth Enhance compound RDSO approved in sealed bag of 10 Kg-03 Nos. (3) Copper strip 150 x 25 x 6 mm-02 Nos. (4) Copper strip 300 x 25 x 6 mm-01 No. (5) 35 Sqmm copper cable to connect earth electrode to MEEB-15 Mtr. approximately. (Inspection by RDSO)" | — | — | — | 36,983.56 | |
| — | 2.00 | — | — | ||
| "Installation of unit earth as per RDSO/SPN/197/Ver 1 or latest, to construct earthing of </= 1 Ohm consisting of: a) Digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the equipment room, exothermic weld material and tools & fixtures for the welding copper tapes and electrodes etc. shall be arranged by the contractor. (Inspection by Consignee)." | — | — | — | 10,341.52 | |
| — | 1.00 | — | — | ||
| Supply of the material for maintenance free Ring Earth consisting of looping of 4 earth pits each as per RDSO specification No. RDSO/SPN/197/2008 or latest amendment and RDSO drawing no. SDO / RDSO/ E&B/001 and 002. (Inspection by RDSO) | — | — | — | 44,908.26 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of the Ring Earth as per RDSO specification no. RDSO/SPN/197/2008 or latest amendment and RDSO Drg. No. SDO/RDSO/E&B/ 001 and 002. All the consumables for mounting the copper tape/bus bar, copper lugs with stainless steel nut and bolts, copper bus bar etc. will be supplied by the contractor free of cost. (Inspection by consignee) | — | — | — | 14,027.44 | |
| — | 5.00 | — | — | ||
| Supply, testing & installation & commissioning of Double face digital platform clock with Blue colour LED & GPS synchronization as per RDSO specification No.RDSO/SPN/TC 62 2008 Rev3.0 or with latest amendment. (including installation accessories such as GPS receiver with connecting RF cable upto sufficient length with hanging Bar, bolt & Nuts, Rain sheds, power cable termination with GPS antenna). (Inspection by RDSO) | — | — | — | 1,30,857.6 | |
| — | 6.00 | — | — | ||
| Supply of 2 Mbps digital Modem conforming to RDSO specification No. RDSO/SPN/TC/80/2013 (rev.1.0) or with latest amendment with following interface 1. carrier end G- 703 E1 interface 2. DTE end V-35 and should work on AC/DC port. (Inspection by Consignee) | — | — | — | 81,886.02 | |
| — | 10.00 | — | — | ||
| Supply and installation of 08 Port 10 / 100 / 1000 base T Layer 2 Smart managed POE Switch with 2 Nos. of SFP Gigabit Uplink port. Make: TP Link/ HP/ Cisco/Juniper/Extreme only. (Inspection by Consignee) | — | — | — | 1,22,673 | |
| — | 3.00 | — | — | ||
| Supply of Ethernet E1 modem pair as per RDSO's specs RDSO/SPN/TC/80/2011. (Inspection by Consignee) | — | — | — | 74,484.9 | |
| — | 6.00 | — | — | ||
| Supply of High throughput LAN extenders as per CR's no.CR/SPN/TC/80/2016 Rev 1.0 effective from 17.10.2016. (Inspection by Consignee) | — | — | — | 1,44,907.38 | |
| — | 1.00 | — | — | ||
| Supply of managed expendable rack type STM-4 ADM L4.2 as per technical no. TEC GR No.TEC/GR/TX/SDH-010/03 JAN 2011 with latest amendment with 2 Nos. STM-4 aggregate optical interface and 2 Nos. STM-1 (S1.1) aggregate optical interface 21 E1s and minimum 8 nos. of 10/100 base T Ethernet port, Orderwire, power supply unit, Subrack DDF, Installation materials, manuals and other accessories. The equipment should be TEC Approved and to be inspected by RDSO. The equipment should be fully wired for its ultimate capacity and provided redundancy for power supply and synchronization. It shall be possible to use the full capacity of the equipment by adding additional tributary cards. Make: Tejas or suitable for existing system installed in Pune division. (Inspection by Consignee) | — | — | — | 2,77,618.54 | |
| — | 6.00 | — | — | ||
| SUPPLY OF Dual band Gigabit Wi-Fi ROUTER with minimum 4x Gigabit LAN Ports and 1x Gigabit WAN Port, minimum 1 year warranty. Make: LINKSYS Velop micro mesh 6 / TP Link Archer Ax1800 / Netgear Nightawk RAX 10. (Inspection by consignee) | — | — | — | 30,711.06 | |
| — | 30.00 | — | — | ||
| Supply of wireless VDSL 2+, 4 port gateway with USB as per instruction of site incharge. Make: Zyxel or Similar. (Inspection by consignee) | — | — | — | 1,07,998.5 | |
| — | 30.00 | — | — | ||
| Supply of Thermo shrink Cable Jointing kit (Reinforced) TSF-2 type generally conforming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.CR/SPN/TC/57(A)/2015 Dt. 06.01.2015 (Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables along with sub-kit (Table-B) for armour continuity. (Inspection by consignee) | — | — | — | 95,934 | |
| — | 30.00 | — | — | ||
| Making of Thermoshrink straight through / derivation / transformer / PIJF cable joint for underground jelly filled cable 6 quad/ 4quad/ 20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site. (Inspection by consignee) | — | — | — | 45,347.4 | |
| — | 6.00 | — | — | ||
| Supply of Hand Held 100 KHz Digital Multimeter. Make: FLUKE/ MECO/ RISHABH. (Inspection by Consignee) | — | — | — | 12,360.3 | |
| — | 1.00 | — | — | ||
| Supply, installation and commissioning of Primary Digital Multiplexing Equipment (PDMUX) as per RDSO specification No. IRS:TC-68/2012 Rev.0 Amdt.1 or with latest amendment compatible to WEBFIL make PD MUX. (Inspection by consignee) | — | — | — | 1,40,087.05 | |
| — | 6.00 | — | — | ||
| Supply of exchange interface cards (4 circuits/ card) compatible with schedule item no. 1 as per RDSO specification IRS/TC/68/12 with latest amendment compatible to WEBFIL make PD MUX. (Inspection by consignee) | — | — | — | 2,76,284.82 | |
| — | 5.00 | — | — | ||
| Supply of 2/4 wire E&M card 4 channels per card as per specification no. IRS/TC/68/12 compatible to WEBFIL make PD MUX. (Inspection by consignee) | — | — | — | 1,71,108.25 | |
| — | 5.00 | — | — | ||
| Supply of 2 MB tributary module for 2 MB programmable primary digital drop insert multiplexer compatible to WEBFIL make PDMUX. (Inspection by consignee) | — | — | — | 4,46,723.95 | |
| — | 5.00 | — | — | ||
| Supply of Network Interface module card as per specn No: IRS-TC-68/12 or with latest amendment compatible with WEBFIL make PDMUX. (Inspection by consignee) | — | — | — | 1,59,662.15 | |
| — | 5.00 | — | — | ||
| Supply of Power supply unit for PD WEBFIL MUX working on 40 Volt to -58 Volt DC input and +5.0 Volt, +10 Volt - 10.0 Volt and +80 Volt DC output as per RDSO specification no. IRS/TC/68/2012. (Inspection by consignee) | — | — | — | 1,64,061.35 | |
| — | 1.00 | — | — | ||
| Supply of GPS tagging featured cable route locator/ tracer set suitable for detecting underground armoured optic fiber cable (OFC) and signaling cables with LCD Graphic Display active/passive modes and depth range. 3M-10m. Model STLOC10 GPS make Stanlay or equivalent. (Inspection by Consignee) | — | — | — | 4,10,148.08 | |
| — | 3.00 | — | — | ||
| Supply and installation of 24 port IPDSLAM Make- Zyxel or similar with Telco 50 cable (02 Nos). (Inspection by Consignee) | — | — | — | 6,31,178.46 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .