| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.5 L+₹5.7 L (14.3%)Rejected-Finance D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹48.7 L+₹8.9 L (22.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹50.0 L+₹10.2 L (25.6%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Apr 2022, 6:00 pmClosed
Garrison Engineer St Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS TO LOW TENSION EXTERNAL ELECTRIFICATION, LT PANELS, STREET LIGHTS AND ALLIED WORKS OF VARIOUS LOCATIONS OF DGQA, PALLAVARAM AND BAFFLE RANGE UNDER GE STM
2022_MES_513139_1
8585-REPAIRS TO LOW TENSION EXTERNAL ELECTRIFICATI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE STM
As per Tender Documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹98,000
Yes
3 Jun 2022
11 Mar 2022
15 Apr 2022
11 Mar 2022
8 Apr 2022
25 Mar 2022
11 Mar 2022 - 24 Mar 2022
Amount
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of stays & Poles, laying of cables etc and getting out in soft / loose soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm using excavated soil all as specified and directed.
Removing excavated material/ surplus soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply, lay / spread in trenches, river sand including cleaning, spreading, levelling, punning for laying /cushioning of cable all as specified and as directed. Note: Punned thickness shall be measured and paid.
M & L for removing old bricks from trenches and supply, lay in trenches burnt Bricks, old size, Sub class "B" for cable protection all as specified and directed. Note: Broken bricks shall be taken as credit.
Relaying the serviceable old bricks in trenches for cable protection all as specified and directed. Note: Serviceable Old Bricks obtained from Item No.5 above shall be reused.
M&L for Cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete including form work.
M&L for Cement concrete Type D2 1:3:6 (20mm graded aggregate) for coping to the poles with finishes with out using extra cement.
Disconnecting and taking out the old unserviceable LT UG cable in trenches, wall & poles and taken as credit including supply and Laying in trenches / poles / wall etc LT UG Cable XLPE insulated, armoured, heavy duty with multistranded aluminium conductor, 1100 volts grade conforming to IS specifications and of the following sizes:- Note: Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used wherever required while connecting cables to the panel board. Earth work such as excavation, refilling etc, shall be measured and paid separately under relevant item:-
(a) LT UG Cable 2 core 10 Sqmm
(b) LT UG cable 4 core 16sqmm
( c ) LT UG cable 4 core 25sqmm
( d ) LT UG cable 3.5 core 35sqmm
( e) LT UG cable 3.5 core 50sqmm
(f ) LT UG cable 3.5 core 70sqmm
( g) LT UG cable 3.5 core 95 sqmm
(h ) LT UG cable 3.5 core 120sqmm
(i) LT UG cable 3.5 core 185sqmm
(j ) LT UG cable 3.5 core 240sqmm
Re- laying only ( where directed at site) in trenches and connecting with suitable size of lugs/ thimble etc. serviceable under ground cable retrieved from taking out as Srl No - 09 of above schedule of following sizes. Note:- These cable shall be laid in particular area and avoided mixing of new & retrieved cables.
(a) LT UG Cable 2 core 10 Sqmm
(b) LT UG cable 4 core 16sqmm
( c ) LT UG cable 4 core 25sqmm
(d ) LT UG cable 3.5 core 35sqmm
(e ) LT UG cable 3.5 core 50sqmm
(f) LT UG cable 3.5 core 70sqmm
(g ) LT UG cable 3.5 core 95 sqmm
(h ) LT UG cable 3.5 core 120sqmm
(i) LT UG cable 3.5 core 185sqmm
(j) LT UG cable 3.5 core 240sqmm
S&F Straight through joints (epoxy) Cold shrink type for underground cable including joint kits and labour complete for making joints suitable for LT PVC sheathed / armoured heavy duty cables with aluminium conductor of following sizes :-
(a) LT UG cable 4 core 16 to 35sqmm
(b) LT UG cable 4 core 50 to 95sqmm
(c ) LT UG cable 3.5 core 120 to185sqmm
(d) LT UG cable 3.5 core 240 to 300 sqmm
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 40mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 80mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 100mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Taking down the old unserviceable junction box and taken as credit including S&F Junction box PVC (FRP) Junction Boxes weather proof type with hinged type door off white colour of size 240x130x110mm with three pole connector and 1 No neutral link complete fixed on pole with suitable clamps, bolts and nuts with fixing arrangements all as specified and directed. Make : Sintex or equivalent.
Dismantling U/S PCC/RCC Poles / struts, any size including old u/s light fitting any type/cap /make /service cable / junction box complete and breaking of existing foundation /pcc coping ,transporting or removing away the broken pole structure complete and making good the disturbed surface of existing location all as directed by Engineer in Charge
Supply and erect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP- 31 (9.00 metres long) conforming to IS-2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bituminous paint over the embedded portion of pole, erecting in truly vertical position including excavation in any strata and earth work complete all as specified and directed. (Make: Calcutta Pole/ Jindal Pole/National Tube Pole. Note :- PCC for foundation and coping will be measured & paid separately under relevant items of Sch 'A'.
M&L for removing the existing street light fitting of any type & make and Supply & installation of new street light fittings,60W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and directed Make:- Havells , Cat part No. ENDURAPEARLNEOSL60WLED757PASYTOPC / Crompton cat part No. LSTP-60-CDL-M/ Wipro skyline LED cat No. LR02-671-XXX-57-XX./Bajaj cat No.ENXT P 60L WW CR PC SD.
M & L for dismantling and taking down the existing street light fitting led type for repair and replacing the unserviceable LED driver with new upto 100W LED 5700K and refixing the same in the existing pole duly wired complete all as specified and directed.
M&L for removing the existing street light fitting of any type & make and Supply & installation of new 90 W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and directed Make:- Havells Cat part ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO/Crompton cat part No. LSTP-90-CDL-M/ Wipro skyline LED cat No. LR02-102-XXX-57-XX/ Bajaj cat No. BRTFG 90W LED CR WW.
Removing the existing Gate light & Supply and installation of new 35W LED 5700K New generation Post top energy saving & environmental friendly long life versatile spun aluminium IP66 roadway luminaries with high power LED as light source and connecting in the existing cable complete all as specified and directed Make:- Havells Cat part RUBYPT35WLED757PSYMTOPC / Bajaj cat part No. BGCT W4 LED WW 40W LED/ Wipro skyline LED cat No. LP02-501-XXX-57-XX
Removing the existing unserviceable bollards light & Supply and installation of new 9 W/10W LED bamboo series IP 65, out door luminaires, New generation energy saving & environmental friendly long life aesthetically designed aluminium land scape luminaire for diffused lighting with high power LED Bollards as light source and connecting in the existing cable complete all as specified and directed Make:- Havells Cat part MOUNTBL10WLED830PSYMTOPMMA/ BAJAJ cat No. BGBOL 605 9W LED WW / CROMPTON cat No. LBLA-10-CDL.
Supply and laying 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 3 core 2.5 sq. mm nominal cross section in service connections/street light connection from junction box to street light fittings.
Dismantling unserviceable power factor improvement capacitor of various capacities and Supply and fix heavy duty Cylindrical capacitors AC 440 volts, 50 Hz, Delta connection new power factor improvement capacitor of following capacities complete all as specified and directed. Make : havells, ABB or equivalent
(a) 25 KVAR Capacity
(b) 20.0 KVAr Capacity
(c ) 15 KVAR Capacity
(d) 10 KVAR Capacity
(e) 5 KVAR Capacity
(f) 3 KVAR Capacity
S & F MCCB 3 pole 400 Amps,415 volts with rupturing capacity 36 KA. All as specified including taking out old one.
S & F MCCB 3 pole 250 Amps,415 volts with rupturing capacity 25 KA. All as specified including taking out old one
S & F MCCB 3 pole 125 Amps,415 volts with rupturing capacity 16KA. All as specified including taking out old one
S & F MCCB 3 pole 100 Amps,415 volts with rupturing capacity 16 KA. All as specified including taking out old one.
Removing of old earthing including earth plate and M&L for Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron earth strip 32 X 6 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe, with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point /plant/machineries etc. including necessary excavation and earth work in any type of soil, salt, charcoal dust, concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, pre-caste RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
Preparation of old surface and painting of steel tubular electric poles above coping level including brackets, clamps etc with good quality silver paint(two coat) complete including writing pole no and all as specified and directed.
Complete servicing, overhauling, repairing, cleaning, oiling with setting of tripping mechanism of Air Circuit Breaker(ACB) 415 volts of capacity 630 amps to 1000 Amps 50Hz any type / any make or all as per existing available at site inluding submission of service & test reports. The servicing to be done by authorised service provider of manufacturer. The details are placed at "Scope of work" as given under. Note :Minimum spares/lubricants and tools required for the job should be included in the coated rates .
SCOPE OF WORK: i) Moving arcing contacts shall be checked. Cleaning of breaker with CRC-226 ii) Removal of old grease and re-greasing the same with recommended grease. iii) Check condition of arcing contact and gap between fixed and iv) Checking the reset mechanism, tripping of breaker through push button v) Checking tripping of ACB through protection release vi) Tripping of ACB manually through volt metric release. vii) Checking and adjust freeness of DN and volt metric release trip rod viii) Checking presence and proper tightening of hardware. ix) Checking presence of all circlips x) Checking condition and alignment of jaw contact with cradle terminals xi) Checking condition of ACB wiring and replace if required xii) Checking and adjusting gap between hylam sheet and side plate xiii) Checking proper closing of all poles together xiv) Checking working of anti pumping device. xv) Checking alignment of SIC and it’s operation xvi) Checking scrapping earth alignment xvii) Checking condition of arc chutes xviii) Checking U/V release pick up and drop off xix) Checking ACB tripping through shunt release xx) Checking continuity and proper changeover of aux contact block xxi) Checking of release by secondary injection for O/L, S/C, E/F xxii) Setting of release as per the load xxiii) Checking the healthiness of CTs
Supply and fixing by replacement of following items of Air Circuit Breaker (ACB) 415 volts 630 to 1000 Amps 50Hz,any type or make or all asper existing
a) Closing Relay
b) Terminal Adaptors (4 terminals per Phase)
c) Relay Module
d) Shunt trip Release
e) Auxiliary Switch
f) Arc Chutes
g) Trip Push Buttons
h) ACB Position Indicator
Finding and rectification of electrical fault by Checking of external/internal(LT) elect supply feeder, street light feeder,OH conductors /under ground cables using elect tools, equipment and safety devices after arranging elect shut down of feeders from sub station to remove elect faults like tightening of loose connection, removing of any electric short,meggring of cable, excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightening of cable lugs etc all as required at site and as directed by Engr in Charge. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safety devices. (ii) Any major materials used for rectification of faults like Cables,MCB/MCCB/cable jointing kits/cables of any type etc will be measured and paid separately (iii) Rate including hire of HT fault Locater and other tools/equipment incl Earth Work. works should be completed with in 12 hrs.
Material and labour for servicing DG Set Engine complete oil servicing, necessary checking of complete cable harness and replacement if required including replacement of below mentioned spares and servicing work for 66KW/82.50 KVA DG Set incl 6 months warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant as required.
Material and labour for servicing DG Set Engine complete oil servicing, necessary checking of complete wiring /harness replacement of same if required as per site condition .Replacement of below mentioned spares and servicing work for 62.50 KVA DG Set Make : Ashoke Leyland incl 6 months warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant as required.
Material and labour for general oil servicing of DG Set Engine complete and checking of serviceability of complete wiring /harness replacement of same as per site condition below mentioned spares and servicing work for 40 KVA DG Set Make : Kirloskar incl 6 months warranty for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant - 1 Ltrs.
Material and labour for servicing DG Set Engine complete oil servicing, necessary checking of complete wiring harness and replacement if required including replacement of below mentioned spares and servicing work for 15 KVA DG Set incl 6 months warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant as required.
Material and labour for general oil servicing of DG Set Engine complete and checking of complete cable harness and replacement if required including replacement of below mentioned spares and servicing work for 12.50 KVA DG Set incl 6 months warranty for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant - 1 Ltrs.
Dismantling self starter of any make from diesel engines of any make, opening up, overhauling / servicing including replacement of armature coils bushes carbon brushes, springs, screws, etc., assembling back, re-fixing and testing for genset capacity following capacity:-
(a)DG Set 82.50 KVA
(b) DG set 62.50 KVA
(c) DG set 40 KVA
(d) DG set 15 KVA
M&L fuel pump & Fuel injectors calibration charges for DG set capacity upto 82.50 KVA complete all as specified and as directed by Eng-in-Charge.
M&L fuel pump & Fuel injectors calibration charges for DG set capacity upto 62.50KVA complete all as specified and as directed by Eng-in-Charge.
'V' belt for fan / dynamo / water pumps for genset capacity upto 82.50 KVA (Make : FENNER / DUNLOP)
M&L fuel pump & Fuel injectors calibration charges for DG set capacity upto 62.50KVA complete all as specified and as directed by Eng-in-Charge.
'V' belt for fan / dynamo / water pumps for genset capacity upto 15/12.5 KVA (Make : FENNER / DUNLOP)
M&L for replacement of automatic voltage regulator (AVR) of armature of DG set capacity upto 82.50 KVA, 415 volts 3 phase 1500 RPM 50 Hz suitable make.
M&L for replacement of automatic voltage regulator (AVR) of armature of DG set capacity upto 62.5 KVA, 415 volts 3 phase 1500 RPM 50 Hz suitable make.
M&L for replacement of automatic voltage regulator (AVR) of armature of DG set capacity upto 15/12.5 KVA, 415 volts 3 phase 1500 RPM 50 Hz suitable make.
Renewal of old unserviceable lead acid rechargeable batteries by new pulse lite zero maintenance battery of 12 volts, 100 AH duly initial charged for Genset Make: Cummins or equivalent makes.
Taking down old unserviceable exhaust pipe with silencer of DG Set 15 KVA and supply & fixing of silencer(Mufflers) spark arrestor Exhaust piping including , expansion joints, Nut bolts, extension MS pipe 6" (150mm), supports insulation or aluminium cladding work etc. complete all as specified.
Material & Labour for Cutting and cleaning the tree branches around the street light poles/ /sub stn/ LT OH line conductors and maintain 2 mtr gap all around free from branches of tree and clear the site and throw away cut branches etc, to a distance exceeding 50m all as directed. Note: Span shall be measured along with the direction of OH/ LT
Supply, install, test & commissioning LT Feeder pillar box out door, floor mounted/pedestal type, cubical, self supported,CPRI approved ,front and rear openable , double door hinged type with locking arrangement and slopping top canopy ,suitable ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc.fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process, mounted/fixed on and including MS angle iron stand of 1.50 mtr height 1.20M x0.60M (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/ capacity of copper strip bus bar, earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming/out going cables etc. Complete all as directed by Engineer-in-Charge and accommodating the followings:-
Supply, install, test & commissioning LT Feeder pillar box out door, floor mounted/pedestal type, cubical, self supported,CPRI approved ,front and rear openable , double door hinged type with locking arrangement and slopping top canopy ,suitable ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc.fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process, mounted/fixed on and including MS angle iron stand of 1.50 mtr height 1.20M x0.60M (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/ capacity of copper strip bus bar, earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming/out going cables etc. Complete all as directed by Engineer-in-Charge and accommodating the followings:-
Supply, install, test & commissioning LT Panel board indoor type , floor mounted/pedestal type, cubical, self supported,CPRI approved ,front and rear openable , double door hinged type with locking arrangement and slopping top canopy ,suitable ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc.fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process, mounted/fixed on and including MS angle iron stand of 2.50 mtr Length x 1.20M Height x0.60M (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/ capacity of copper strip bus bar, earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming/out going cables etc. Complete all as directed by Engineer-in-Charge and accommodating the followings:-
Supply, install, test & commissioning LT Feeder Pillar Box out door, floor mounted/pedestal type, cubical, self supported,CPRI approved ,front and rear openable , double door hinged type with locking arrangement and slopping top canopy ,suitable ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc.fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process, mounted/fixed on and including MS angle iron stand of 1.5 mtr height x1.2Mx0.60M (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/capacity of copper strips for switch gear connection from main bus bar, earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming/out going cables etc. Complete all as directed by Engineer-in-Charge and accommodating the followings:-
Removing the existing Garden light & Supply and installation of new 8W/ 9 W/ 10W LED cone series IP 65, out door luminaires, graphite grey powder coated GI pipe housing mushroom shape opal acrylic diffuser is fixed in die-cast aluminium base pleasant light output as light source and connecting in the existing cable complete all as specified and directed Make:- Bajaj Cat part TULIP-BGBOM605 9W LED WW /Havells Cat No. CONENXGBLS8WLED830PSYMTOPC/ CROMPTON Cat No. LBLTW-10-WW.
Repair/rewinding of existing unserviceable burnt alternator of capacity 12.5 KVA after necessary disconnecting all cable connections of incoming/outgoing and dismantling from engine side transporting to local authorised workshop including cutting removing burnt winding from stator assy ,cleaning stator slots, inserting insulation sheets, rewinding with original gauge of winding wire ,varnishing, baking complete reassembling alternator assy with engine at site ,reconnecting all incoming/outgoing cables ,checking of serviceability of AVR ,Replacement of complete wiring/horness of alternator testing of DG on full load all as directed by Engineer in charge
Repair/rewinding of existing unserviceable burnt alternator of capacity 15 KVA after necessary disconnecting all cable connections of incoming/outgoing and dismantling from engine side transporting to local authorised workshop including cutting removing burnt winding from stator assy ,cleaning stator slots, inserting insulation sheets, rewinding with original gauge of winding wire ,varnishing, baking complete reassembling alternator assy with engine at site ,reconnecting all incoming/outgoing cables ,checking of serviceability of AVR ,Replacement of complete wiring/horness of alternator testing of DG on full load all as directed by Engineer in charge
S.M.ELECTRICALS
Vantage System and Sevices
EVEREST ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .