GE 881 EWS, C/O 56 APO
GE 881 EWS, C/O 56 APO
REPAIR TO ROOF, FLOORING AND PLUMBING INCLUDING INTERNAL WIRING IN BG, HAMIRPUR AND MENDHAR AND REPAIR/REPLACEMENT OF INTERNAL E/M FITTING AND FIXTURE AT BG/HAMIRPUR/JWG UNDER GE 881 EWS.
2025_MES_734296_1
GE/PNH-77/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS, C/O 56 APO
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 881 EWS
₹67,740
Yes
8 Oct 2025
8 Oct 2025
7 Nov 2025
8 Oct 2025
4 Nov 2025
22 Oct 2025
Socket outlet modular type 3 pin 15 amp flush type complete all as specified and directed.
Taking down tarfelt/cement plaster and roughening of concrete surface by picking, sweeping clean by using steel wire brush and washing down with water, fanning dust etc and removing demolished material n.exc. 50m, complete including dismantling existing lightening conductor and refixing in same location including repair/replacement if not working after completion of roof treatment complete all as specified and directed by Engr-in-Charge.
Providing levelling course of cement concrete in roof, Type B0 ,1:2:4 using 12.5 mm graded aggregates including brushing neat cement slurry on existing concrete surface @ 3Kg cement per sqm complete all as specified and directed.
Material and labour for roof surface treated with PU Elastoseal primer to seal the pores and enhance the adhesion of the coating, supplying and applying single component waterproofing liquid membrane based on pure, elastomeric, polyethene resin cold applied of spray/brush applied membrane with an elongation of 650%+50 and tensile strength not less than 2 Mpa. crack bridging ability not less than 2mm. No leakage upto 5 bars of water pressure. Shore Hardness > 50 Shore. The minimum thickness to be applied shall be 1.5mm (overall) in two layers (each layer 750 micron) or as per manufacturers instructions so as to achieve thickness not less than 1.5mm including providing & laying of protective Geotextile fabric 150 GSM over than entire membrane with proper overlaps of 75mm complete all as specified and as directed by Enge-in-charge. Note: (i) The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer. (ii) Payment will be made after providing warranty certified from the company.( Makes of PU Primer/Membrane SIKA/BASF, BERGER/STP FOSROC/SAINT GOBAIN, PIDILITE.)
Supply only liquid water proofing compound complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall,fixed with self tapping screwed complete all as specified and directed.
Providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in roof kerbs or mud stops, coping etc rounded or chamfered on edge including necessary form work complete all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats Fe-410-W (Gde E-250) quality B etc complete all as specified and directed.
Dismantling of wall and ceiling boards any thickness of any description including cover fillets complete all as specified and directed.
Preparation of new or previously untreated steel or iron surfaces of any description, not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Hangers 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hlod fasteners 12.5mm dia 40mm long for grid size 605 x 605mm complete all as specified and directed.
Powder coated Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre of grid size 605 x 605 mm complete all as specified and direc
Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site but wood grain printed PVC sheet used instead of plain colour sheet as per specifications and drawing complete all as specified and directed.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Glazed ceramic coloured tiles of size 450 mm x 350 mm x 7mm/ 350x 250x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specified provided complete all as specified and directed.
Vitrified Ceramic tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-in-Charge
Taking down cement plaster from brick or stone walls hacking for keys & scrubbing down with water including raking of joints etc as in patches complete all as specified and directed.
Preparation of new wall surfaces and applying two coats of cement base paint over a coat of Primer complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces including finishing even and smooth without using extra cement complete all as specified and as directed.
Preparation of new plaster surfaces of wall and applying two coats of OBD over a coat of primer including 1 to 2mmthick wall care putty complete all as specified and directed.
Tank nipple suitable for HDPE water tank complete all as specified and directed. (Minimum weight 15 mm-38gms/20mm 45gms /25mm- 65gms)
Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and directed.
Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. .
One bell point controlled by one bell push complete all as specified and directed.
M & L for point wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through including PVC casing caping and provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed.
One light/fan point controlled by one switch 6 amp one way complete all as specified and directed.
Piano flush type single pole, one way 6amp complete all as specified and directed.
Switch piano flush type single pole, one way 15 amp complete all as specified and directed.
Socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed.
Socket outlet 2 in 1 , 3 pin 5 A and 15 A flush type complete all as specified and directed.
Each Point
LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Replacement of PVC casing caping of size 25 mm incl all fixing accessories complete all as specified and directed.
Replacement of flexible PVC conduit of approved quality of size 25 mm dia bore with fixing materials complete, and as directed by Engineer-in-charge.
Supply only copper Flexible twin twisted wire, PVC, 10/0.2 gauge complete all as directed by Engr-in-Charge.
Supply only tape insulation 20mm x 25 mtrs, complete all as specified and directed.
Supply and fixing in repair Plug top 15 Amps, 230Volt, 50Hz complete all as specified and directed.
Supply only flexible LED Strip light with adopter water proof, multi-color, suitable for 230V, 50Hz complete all as specified and directed.
All as per item No.119 here in above but twin core 16 sqmm complete all as specified and directed.
Description all as per srl item No 38 above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC casing caping 25mm dia conduit heavy duty complete all as specified and directed.
Distribution board double door type(for incoming MCCB & outgoing MCBs) TPN 4 way vertical type sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and as directed.
Replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
Submain wiring in relacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC casing caping medium grade ISI marked 25mm dia as per IS specification fixed in new on wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper ccomplete all as specified and directed. Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
All as per item No. 109 here in above but 8 way complete all as specified and directed.
MCCB four pole 415 Volts, 100 A, 25 KA complete all as specified and directed.
MCB three pole and neutral isolator 415 Volts, 63 A, 25 KA complete all as specified and directed..
MCBs 5 to 40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holde
r, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
MCBs 5 to 40 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
All as per srl item 62 above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed. Note: For item 2 :- The rate of chase cutting and making good the surface will be deemed in the rates quoted by the contractor.
All as per item No 138 here-in-before but of cap 1.5 KW complete all as specified and directed.
Lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed.
S&F in replacement plug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified and directed.
All as per item No 119 here in above but twin core 6 sqmm complete.
All as per item No.119 here in above but twin core 10 sqmm complete all as specified and directed.
Taking out of ceiling/exhaust fan/Air circulator fan from AGE E/M store yard/Site and transport to reputed workshop for rewinding the fan starter with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge of following sizes:- (Bushes, shafts, bearings, capacitors, flexible wires,painting etc. shall be measured and paid separately)
Geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified & directed.
Ceiling Fan (1200/ 1400 mm) size of any make complete all as specified and directed.
Exhaust Fan of 230/300mm size of any make complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm bore medium grade,wire mesh and lugs,GI protection pipe,15mm bore,light grade,7.5 mtr long for protection of earth lead upto test point etc including taking down existing unserviceable earthing complete all as specified and directed.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspebded by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 4 sqmm solid aluminium conductor complete all as specified and directed.
3 core PVC flexible copper conductor cable(cord) of 0.5 Sqmm complete all as specified and directed.
Blades for ceiling fans of size1200mm/1400mm size of any make complete all as specified and as directed.
Each Set of three
Replacement of capacitor 4.0/2.5 mfd capacity (condenser) of exhaust and ceiling fans complete all as specified and directed.
S&F in repairs energy efficient LED street light fitting (beamer), 45W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, minimum 50000 burning hours, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 90W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc for fixing at any locationscomplete all as specified and directed.
M.S. clamps for hanging ceiling fan with nuts, checknuts and bolts 2" x 3/8" : 02 Nos. including rubber rings(reel) for hanging ceiling fans complete all as specified and as directed.
S&F in replacement street light GI pipe bracket 40mm dia 1.50m length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed.
LED lamp 7 watt complete all as specified and directed.
Ceiling fan 1200mm sweep with 3 blades, electric driven single phase 240 volt 5 str rated, BEE energy effecient and connecting up including provision of cable from ceiling rose or connector to fan to make it functional complete all as specified and directed.
Steel body, heavy duty, exhaust fan 300 mm sweep single phase 230 volts including louvers and fixing arrangement as per site requirement complete all as specified and directed.
M&L for disconnecting elect & water connection to geyser of cap 25/50/35 ltr, taking down, from existing position, dismantling and inspecting all the parts, for its serviceability, cleaning of serviceable parts i.e. Heating elemet, base assy, connecting lead, thermostat, electrical contact, electric wiring, indicators, safety valves etc and refixing, replacement of unserviceable parts, re assembling, remounting, reconnecting with electrical & water connectionn and testing complete all as specified and directed. Notes(i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch 'A' as supply only.(ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
LED lamp 9 watt complete all as specified and directed.
Geyser pipe connection heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature for existing geyser complete all as specified & directed.
Indicator lamp as per existing make and size complete all as specified & directed.
Only inner tank made out of steel sheet conform to IS suitable for 25 ltrs capacity of geyser of different makes vertical type all as specifie and directed.
Heating element 2.0 KW, ISI marked with gasket suitable for as existing size, type and make of geyser under repair complete all as specified and directed.
New base assembly with inlet and outlet pipe made out of steel base plate with gasket and proper size of nuts, bolts and washer etc suitable for 25 ltrs capacity of geyser complete all as specified & directed.
Thermostat ISI marked suitable for exis
All as per item No 148 here-in-before but of size 35/50 ltrscomplete all as specified & directed.
All as per item No 145 here-in-before but but for Geysers of capacity 35/50 ltrs complete all as specified & directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
TENDER77.pdf
Tender Documents • 1.32 MB
BOQ_822214.xls
BOQ • 1.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .