| Sl No | Description | Qty | Unit | M/S SYED YAQOOB CONSTRUCTIONS L1 | M/S CHINAR DRILLERS L2 |
|---|---|---|---|---|---|
| 1.00Part A: Realignment of 33kv Pampore Chadoora line at wathora near Masjid Sharief | |||||
| 2.00 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP -56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 4 | No | 27,500 ₹1,10,000 | 24,945 ₹99,780 Lowest |
| 3.00 | Proviidng,Laying,stringing ,tensioning and binding of 200 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 0.25 | KM | 2,30,000 ₹57,500 Lowest | 2,52,333 ₹63,083.25 |
| 4.00 | Providing and fixing of fabricated GI Channel X-arm including clamps and braces (including GI nuts and bolts with washers) as per site reqirement. | 290 | Kgs | 145 ₹42,050 | 144 ₹41,760 Lowest |
| 6.00 | Providing and fixing of fabricated GI V cross-arm/ cantilever with top Bracket including clamp including GI nuts and bolts with washers) as per site reqirement. | 40 | Kgs | 135 ₹5,400 Lowest | 144 ₹5,760 |
| 7.00 | Providing and laying of Cement bottoming of 11 mtrs long ST Poles in mix of 1:2:4 using 20mm crushed stone aggregate including shuttering, form work etc as per REC standards 0.66cum/pole. | 4 | No | 3,000 ₹12,000 Lowest | 4,870 ₹19,480 |
| 8.00 | Providing and fixing of Earthing of ST poles Complete by by GI pipe 40mm 3 mtr long through GI strip 25x3mm, as per REC standards. | 4 | No | 1,150 ₹4,600 Lowest | 2,076 ₹8,304 |
| 9.00 | Providing and fixing of PG Clamps for 200 mm² ACSR Conductor. | 12 | No | 500 ₹6,000 Lowest | 831.87 ₹9,982.44 |
| 10.00 | Supply,installation,testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900m, suitable for 0.2ACSR OF REPUTED MAKE AS PER REC STANDARDS. | 12 | No | 850 ₹10,200 | 747 ₹8,964 Lowest |
| 11.00 | Supply,installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm. Complete with tension fittings suitable for 0.2ACSR OF REPUTED MAKE AS PER REC STANDARDS. | 6 | No | 1,250 ₹7,500 | 1,157.51 ₹6,945.06 Lowest |
Tender Value
₹3.9 L
EMD Value
₹7,732
Closing Date
1 Nov 2025, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
ffice of the Executive Engineer, STD-II, Rajbagh
Realignment of existing 33kv Pampore Chadoora line at Wathora near Masjid Sharief and Realignment Shifting 33kv line on Wathoora Bunhar road near the house of Gh Rasool Waza and others at Wathora as desired by Honourable MLA Chadoora
2025_PDD_291658_1
eNIT No STD-II / 43 of 2025-26 Dated 11-10-2025
Open Tender
Electrical Works
Turn-key
Budgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹200
Executive Engineer, STD-II, Rajbagh,Srinagar
₹7,732
6 Nov 2025
11 Oct 2025
3 Nov 2025
11 Oct 2025
1 Nov 2025
11 Oct 2025
Amount
Part A: Realignment of 33kv Pampore Chadoora line at wathora near Masjid Sharief
Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP -56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any).
Proviidng,Laying,stringing ,tensioning and binding of 200 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any).
Providing and fixing of fabricated GI Channel X-arm including clamps and braces (including GI nuts and bolts with washers) as per site reqirement.
Providing and fixing of fabricated GI V cross-arm/ cantilever with top Bracket including clamp including GI nuts and bolts with washers) as per site reqirement.
Providing and laying of Cement bottoming of 11 mtrs long ST Poles in mix of 1:2:4 using 20mm crushed stone aggregate including shuttering, form work etc as per REC standards 0.66cum/pole.
Providing and fixing of Earthing of ST poles Complete by by GI pipe 40mm 3 mtr long through GI strip 25x3mm, as per REC standards.
Providing and fixing of PG Clamps for 200 mm² ACSR Conductor.
Supply,installation,testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900m, suitable for 0.2ACSR OF REPUTED MAKE AS PER REC STANDARDS.
Supply,installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm. Complete with tension fittings suitable for 0.2ACSR OF REPUTED MAKE AS PER REC STANDARDS.
Providing and fixing of Anti Climbing Devices with clamps of standard make
Providing and fixing of Danger Plates with clamps of standard make
Providing and painting of 11 mtrs long ST Poles with One coat of Red Oxide and two coates of Aluminium Paint to give even shade (reputed brand)
Part B: Realignment/Shifting 33kv line on Wathoora Bunhar road near the house of Gh Rasool Waza and others at Wathora
Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP -56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any).
Proviidng,Laying,stringing ,tensioning and binding of 100 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any).
Providing and fixing of fabricated GI Channel X-arm including clamps and braces (including GI nuts and bolts with washers) as per site reqirement.
Providing and laying of Cement bottoming of 11 mtrs long ST Poles in mix of 1:2:4 using 20mm crushed stone aggregate including shuttering, form work etc as per REC standards 0.66cum/pole.
Providing and fixing of Earthing of ST poles Complete by by GI pipe 40mm 3 mtr long through GI strip 25x3mm, as per REC standards.
Providing and fixing of PG Clamps for 100 mm² ACSR Conductor.
Supply,installation,testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900m, suitable for 0.2ACSR OF REPUTED MAKE AS PER REC STANDARDS.
Supply,installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm. Complete with tension fittings suitable for 0.2ACSR OF REPUTED MAKE AS PER REC STANDARDS.
Providing and fixing of Anti Climbing Devices with clamps of standard make
Providing and fixing of Danger Plates with clamps of standard make
Providing and painting of 11 mtrs long ST Poles with One coat of Red Oxide and two coates of Aluminium Paint to give even shade (reputed brand)
M/S CHINAR DRILLERS (BID ID -2624998)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 1.58 MB
BOQ_938887.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .