Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.9 L+₹32,370 (4.25%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.0 L+₹36,370 (4.78%)Rejected-Finance 41 CUSTODIAN ANNEXE BEHIND WOOD LAND SCHOOL SHIVPORA SRINAGAR JAMMU KASHMIR 190004 | SRINAGAR | JAMMU AND KASHMIR | 190004 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹9.3 L+₹1.7 L (21.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹7.7 L
EMD Value
₹15,400
Closing Date
8 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 WE
HQ 134 WE PIN - 914 134 C/o 56 APO
PROVN OF 01X 63 KVA DG SET WITH AMF PANEL AT SHARIFABAD UNDER AGE (I) CIF (K)
2020_MES_347056_2
134 WE-17/2020-21
Open Tender
Civil Works
Item Rate
180 days
Srinagar
AS per tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE (I) CIF (K)
₹15,400
Yes
29 Aug 2020
21 Jul 2020
10 Aug 2020
21 Jul 2020
8 Aug 2020
24 Jul 2020
60 days
Amount
Supply, installation, commissioning and testing of Diesel engine/ Driven Gen set of capacity 63 KVA (62.5 KVA), 50 KW at NTP (0.8 PF) liquid cooled 4 stroke, multicylinder coupled to brush less type 415 volts 50 cycle/second self exited complete with cushy pads, silencr, injectors, advance gensets controller PSO 600, AAMF Panel for automatic starting on main failure, mounted on common base plate form with flexible coupling, 1500 RPM, alongwith sound proof enclosure (Acoustic enclosure) designed for reducing the sound level to less than 75 db at 1.00m as per approved CPCB norms and as per GSR 37 (E) dt 17 May 2002 as amended from time to time with silencer pipe and salience muffler covered with asbestos rope 25m thick independently supported from Engine to out side of power house up to 1m, cold start kit, battery start with suitable size cable for connecting from DG Set to DG set panel board. DG Set shall be capable of operating in temperature range of (- 150 C to + 390 C) and comprising the following components ( Including foudation of DG set as per manifacturer size and specification ) :- Make of Engine: CUMMINS model No 4BTAA3.3-G11/Gen set model No C62.5D5P or its equivalent model for make Kirloskar/ Mahindra. Make of Alternator: Stamford (CGT), Model No S1L2-Y1 enclosure IP 23, H class insulation, winding pitch 2/3 or its equivalent model for make Crompton Greaves/Bharat Bijlee.
(a) Diesel Engine: Desel enginer 4 cylinders, 4 stroke cycle, Radiator cooled, engine well designed air handling system with:- (i) Dry type, heavy duty, replaceable paper element air cleaner with restriction indicator. (ii) Air to air after cooling. (iii) Optimised turbo charger for increased altitude capabilities. (b) Best in class fuel economy with: (i) In line fuel pump with A1 class mechanical governing. (ii) Spin in fuel filter. (c) Standard inegral set mounted radiator system, designed and tested for 50 degree C ambient tmperature. (d) Full flow spin on lube oil filter. (e) First fill of lube oil and coolant. (f) Electrical starter motor with soft start engagement feature. (g) Battery charging alternator. (h) 1 x 12 DC battery.
ALTERNATOR (a) Stampford S1L2 alternator for Cummins Generator Technologies. (b) Brushiess type, screen protected, Revolving filled, self excited alternator conforming to IS/IEC 60034-1. (c) 3 Phase reconnectable winding with 12 terminals brought out for connection. (d) Dedicated winding specially designed for 1 Phase operation. (e) Better motor starting capability. (f) Best in class efficiency. (g) Compact design with sealed bearing for longer life and lesser maintenance. (h) Impregnation on all wound components for better mechanical stength.
(a) AMF functionality. (b) Intutive operator interface which includes LED backlit 128x64 pixel graphic deisplay with tactile feet soft switches. Indicators Generator set, Utitlity status Lamp. (c) Remote Start - Stop. (d) Engine metering Oil pressure, Engine temperature, starting battery voltage, Engine running hours. (e) AC alternator metering L-L voltage and L-N voltage, current (Phase and total), KVA (Phase and total) and frequency Kwh, Total & per phase (Kw & KVA), PF, utility voltage and frequency. (f) Engine protection: Low lube of pressure, High/Low coolant temperature, Battery over/under weak volts, Fall to crank/start, sensor failure, cranking lockout, Lowfuel level. (g) AC alternator proection, over/under voltage, Over/Under frequency, Loss of AC sensing, Oversped, Over current. (h) Data Logging, Engine hours, control hours and upto 5 recentfault codes. (j) Configurable glow plug control. (k) 12/24 Volt DC operation. (l) Sleep mode. (m) Modbus interface (RS485 RTU) (n) In Power compatible (PC based service tool) (o) Certifications-meets the requirements of relevant ISO, EN, Mil Std and CE standards (p) Maintenance due alarm based on Engine Run Time and due date. (q) Exeroisor scheduler.
Base rail made out of suitable channel duly reinforced and provided with adequate numbers of anti vibration pads to ensure minimum vibration as recommended by manufacturer with integral fuel tanks provided.
Batteries maintenance free of suitable size and Nos as per recommendations of manufacturer's alongwith the connecting leads and battery stand.
Accousitque enclosure with natural air circulation without loss of any power for ventilation fan. The enclosure shall be modular in construction withhinge bolted structure to provide easy dismanling and shall be made out of high quality CRCA sheet steel of 1.6 mm thick with sufficient accessories for maintenance work, openable and lockable door with air tight rubber gasket, interior lighting arrangement.
Cost of necessary foundation as per drawing, design provided and recommended by manufacturer is inlcuding under this item.
XLPE UG cable, 1100 volts grade, PVC insulated, heavy duty, armoured, multistranded aluminium conductor cable of size 95 Sqmm 3 core in trenches, through pipe, under culvert or in air complete all as specified and directed by Engr-in-Charge. Note:- Earth work, sand cushioning and brick shall be measured and paid separately)
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out hard/ dense soil for laying of cable, errection of pole, stays etc complete all as specified and directed by Engineer-in-charge.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engineer -in-charge.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed by Engineer -in-charge.
River sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured
M&L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick, 32x6mm GI strip, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead GI strips 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 of SSR 2009 Part-I connected to earthing test point all as specified or indicated including earth work in any type of soil, charcoal dust, common salt, 20mm bore light grade watering pipe, wire mesh, funnel, PCC pit 1:2:4 type B1 and 40mm thick cover of RCC (1:2:4) type B-O reinforced with X PM of weight not less than 4 Kg/Sqm and with 6mm dia MS bar handle made to shape, 40mm bore protection pipe light grade upto 15mm bore long 5 mtr long and GI strip upto main earthing of pole, complete all as specified and directed by Engr-in-Charge. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department.
M/S MARVEL ELECTRICALS
Razdan Builders and Suppliers
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .