| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹48.7 L+₹3.5 L (7.72%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹50.9 L+₹5.7 L (12.6%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹58.9 L+₹13.7 L (30.3%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended being not meeting the enlistment criteria and declared unenlisted being sad demise of one partner by HQ CELZ QE June 24 |
| Sl No | Description | Qty | Unit | Uma engineers L3 | M/S Rakesh Verma L2 | lodhi builders L4 | Om Electricals L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M & L for cleaning, servicing, overhauling all component of Air Handling Unit including dismantling of side panel where as required, cleaning of heating & cooling coil with caustic soda solution, including welding/brazing, wherever required to arrest leakages, cleaning of Pre-Micro filters, replacing of vertical GI sheet supports, replacement of U/S foam insulation of best quality using adhesive substance to avoid cold air leakages, greasing of bearing and re-assembling all the dismantled components and other packing material to its original position as existing etc, with and including testing, commissioning of air handling unit of size up to 10000 CFM at optimum efficiency, complete all as specified and directed. | 1 | Each Job | 1,574 ₹1,574 Lowest | 5,000 ₹5,000 | 10,000 ₹10,000 | 6,000 ₹6,000 |
| 2.00 | M & L for cleaning, servicing, overhauling all component of Air Handling Unit including dismantling of side panel where as required, cleaning of heating & cooling coil with caustic soda solution, including welding/brazing, wherever required to arrest leakages, cleaning of Pre-Micro filters, replacing of vertical GI sheet supports, replacement of U/S foam insulation of best quality using adhesive substance to avoid cold air leakages, greasing of bearing and re-assembling all the dismantled components and other packing material to its original position as existing etc, with and including testing, commissioning of air handling unit of size up to 10000 CFM to 20000 at optimum efficiency, complete all as specified and directed. | 4 | Each Job | 1,888 ₹7,552 Lowest | 5,000 ₹20,000 | 10,000 ₹40,000 | 6,500 ₹26,000 |
| 3.00 | M & L for cleaning, servicing, overhauling all component of Air Handling Unit including dismantling of side panel where as required, cleaning of heating & cooling coil with caustic soda solution, including welding/brazing, wherever required to arrest leakages, cleaning of Pre-Micro filters, replacing of vertical GI sheet supports, replacement of U/S foam insulation of best quality using adhesive substance to avoid cold air leakages, greasing of bearing and re-assembling all the dismantled components and other packing material to its original position as existing etc, with and including testing, commissioning of air handling unit of size up to 20000 CFM to 30000 at optimum efficiency, complete all as specified and directed. | 6 | Each Job | 2,360 ₹14,160 Lowest | 5,000 ₹30,000 | 10,000 ₹60,000 | 7,000 ₹42,000 |
| 4.00 | Supply only the following spares / parts suitable for Air handling units repaired under respective Sch ‘A’ item No. 01 to 03 for servicing / overhauling of AHU complete all as specified and directed.
(a) Pedestal bearing no NTN 205 J (Japan) or equivalent of make SKF /NBC complete all as specified and directed. | 4 | Each | 1,800 ₹7,200 | 950 ₹3,800 | 700 ₹2,800 Lowest | 2,100 ₹8,400 |
| 4.01 | (b) Pedestal bearing no NTN 206 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed | 4 | Each | 1,900 ₹7,600 | 1,000 ₹4,000 Lowest | 1,400 ₹5,600 | 2,400 ₹9,600 |
| 4.02 | (c) Pedestal bearing no NTN 207 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed | 4 | Each | 2,100 ₹8,400 | 1,200 ₹4,800 Lowest | 1,500 ₹6,000 | 2,500 ₹10,000 |
| 4.03 | (d) Pedestal bearing no NTN 211 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed. | 4 | Each | 2,200 ₹8,800 | 1,500 ₹6,000 Lowest | 1,500 ₹6,000 Lowest | 2,500 ₹10,000 |
| 4.04 | (e) Mild steel shaft pulley 8” dia, B section, double groove inner bore 32mm with suitable slot for key complete all as specified and directed | 2 | Each | 1,696 ₹3,392 Lowest | 10,500 ₹21,000 | 10,000 ₹20,000 | 1,850 ₹3,700 |
| 4.05 | (f) Mild steel shaft pulley 8” dia, B section, three groove inner bore 25mm with suitable slot for key complete all as specified and directed. | 2 | Each | 1,696 ₹3,392 Lowest | 12,500 ₹25,000 | 12,500 ₹25,000 | 1,750 ₹3,500 |
| 4.06 | (g) Mild steel shaft pulley 4” dia, B section, double groove inner bore 25 mm with suitable slot for key complete all as specified and directed. | 2 | Each | 1,650 ₹3,300 Lowest | 12,000 ₹24,000 | 14,500 ₹29,000 | 1,800 ₹3,600 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Jun 2025, 6:00 pmClosed
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIR / MAINT OF AHU, COOLING TOWERS, DUCTS, INSULATION, ETC OF CENTRAL AC PLANT OF DIFFERENT CAPACITY AND REPAIR / MAINT OF SPLIT / WINDOW AC , SUMMER COOLING APPLIANCES ALONGWITH CONNECTED WORKS IN CERTAIN BLDGS IN EAST WING TECH AREA AF STN GWALI
2025_MES_707979_1
8900/1592/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹98,000
Yes
6 Aug 2025
13 May 2025
17 Jun 2025
13 May 2025
10 Jun 2025
27 May 2025
Amount
M & L for cleaning, servicing, overhauling all component of Air Handling Unit including dismantling of side panel where as required, cleaning of heating & cooling coil with caustic soda solution, including welding/brazing, wherever required to arrest leakages, cleaning of Pre-Micro filters, replacing of vertical GI sheet supports, replacement of U/S foam insulation of best quality using adhesive substance to avoid cold air leakages, greasing of bearing and re-assembling all the dismantled components and other packing material to its original position as existing etc, with and including testing, commissioning of air handling unit of size up to 10000 CFM at optimum efficiency, complete all as specified and directed.
M & L for cleaning, servicing, overhauling all component of Air Handling Unit including dismantling of side panel where as required, cleaning of heating & cooling coil with caustic soda solution, including welding/brazing, wherever required to arrest leakages, cleaning of Pre-Micro filters, replacing of vertical GI sheet supports, replacement of U/S foam insulation of best quality using adhesive substance to avoid cold air leakages, greasing of bearing and re-assembling all the dismantled components and other packing material to its original position as existing etc, with and including testing, commissioning of air handling unit of size up to 10000 CFM to 20000 at optimum efficiency, complete all as specified and directed.
M & L for cleaning, servicing, overhauling all component of Air Handling Unit including dismantling of side panel where as required, cleaning of heating & cooling coil with caustic soda solution, including welding/brazing, wherever required to arrest leakages, cleaning of Pre-Micro filters, replacing of vertical GI sheet supports, replacement of U/S foam insulation of best quality using adhesive substance to avoid cold air leakages, greasing of bearing and re-assembling all the dismantled components and other packing material to its original position as existing etc, with and including testing, commissioning of air handling unit of size up to 20000 CFM to 30000 at optimum efficiency, complete all as specified and directed.
Supply only the following spares / parts suitable for Air handling units repaired under respective Sch ‘A’ item No. 01 to 03 for servicing / overhauling of AHU complete all as specified and directed. (a) Pedestal bearing no NTN 205 J (Japan) or equivalent of make SKF /NBC complete all as specified and directed.
(b) Pedestal bearing no NTN 206 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed
(c) Pedestal bearing no NTN 207 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed
(d) Pedestal bearing no NTN 211 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed.
(e) Mild steel shaft pulley 8” dia, B section, double groove inner bore 32mm with suitable slot for key complete all as specified and directed
(f) Mild steel shaft pulley 8” dia, B section, three groove inner bore 25mm with suitable slot for key complete all as specified and directed.
(g) Mild steel shaft pulley 4” dia, B section, double groove inner bore 25 mm with suitable slot for key complete all as specified and directed.
(h) Cast copper alloy gate valve 20mm nominal bore, screwed down high pressure, with crutch or butter fly handle complete all as specified and directed.
(j) Cast copper alloy gate valve 25mm nominal bore, screwed down high pressure, with crutch or butter fly handlec complete all as specified and directed Note (i) Cost element of removing unserviceable parts, fixing and testing of the new items/ parts is deemed to be included in the respective rates quoted by the contractor under respective Sch ‘A’ item No. 1 to 03 for servicing / overhauling of AHU. (ii) Contractor shall have no claim on account of variation of quantities of these items/non execution of any of the above items and contractor shall be paid for at as quoted rates only for the parts actually replaced.
M&L for servicing /descaling of Hot water generator up to 170 KW 3 phase, 415 volts and calibration testing of all functional with including replacement of any minor defective parts such as bolts, nuts and screw etc.
Disconnecting and taking out existing unserviceable heater of 14 KW/3KW any description and in any position complete all as specified & directed.
Supply and fix in repair and commissioning Hot Water Generator Set heating element 14 KW complete including flushing of pipe line and brazing as required all as directed for satisfactory operation of plant.
Supply and fixing in replacement strip heater 3 KW, 230 volts fin type complete all as specified & directed.
Supply and fixing in replacement of PCB for hot water generator as per existing of capacity upto 30KW complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in replacement of PCB as per existing for hot water generator of capacity above 30 KW and upto 63KW complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in replacement of PCB as per existing for hot water generator of capacity above 63 KW and upto 170 KW complete all as specified and directed by the Engr-in-Charge.
Supplying, laying, commissioning in replacement of chilled / hot water M S Pipe line along with tee, bend, elbow, flanges, PCC supports of size 150 mm bore, heavy grade with all fittings / welding as required at site, laid in floors or fixed to walls / supports and ceilings for AC plants complete all as specified and directed.
All as per item No 12 here-in-before but of size 100 mm bore
All as per item No 12 here-in-before but of size 80 mm bore
All as per item No 12 here-in-before but of size 65 mm bore
All as per item No 12 here-in-before but of size 50 mm bore
All as per item No 12 here-in-before but of size 40 mm bore
Supplying, laying , commissioning including testing in replacement of cast iron butter fly valve as per sample of size 200 mm bore complete all as specified and directed.
All as per item No18 here-in-before but of size 150 mm bore
All as per item No18 here-in-before but of size 100 mm bore
All as per item No18 here-in-before but of size 80 mm bore
All as per item No18 here-in-before but of size 65 mm bore
Taking out & removing old burnt out windings and rewinding of electric motors of following sizes with existing size copper super enameled wire including insulating material such as aluminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc including testing and refixing to original position for the following capacities. (Note : Rates are inclusive of transportation, labour etc, complete. (a) 0.5 HP to 1.5 HP single phase 50 Hz
(b) 2.0 HP to 3.0 HP Three phase 50 Hz
(c) 5.0 HP Three phase 50 Hz
(d) 7.5 HP Three phase 50 Hz
(e) 10 HP to 12.5 HP Three phase 50 Hz
(f) 15 HP Three phase 50 Hz
(g) 20 HP Three phase 50 Hz
Supply only ball Bearing/Roller Bearing of the following Sizes complete all specified and directed by the Engineer-in-Charge. (a) 6202Z/6204Z
(b) 6307Z/6308Z/6209Z/6310Z/6312Z/6313Z
Supply only gun metal bushes suitable for following capacity of pumps of any make/model :- (a) 02 to 05 HP Pump
(b) 7.5 to 12.5 HP Pump
(c) 15 to 20 HP Pump
Supply only MS star coupling, rubber coupling L – 190 for pump and Motor or as approved by GE. Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective item of Sch ‘A’.
Supply only cast iron gland plate for pumps suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Supply only cast iron gland bolts made out of high carbon forged steel complete with nuts & washers suitable for following capacity of pumps of any make/model : (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 15/20 HP, three phase, 50 Hz
Dismantling and taking down/removing of damaged fan blades of any description and in any position from electric motors all as directed and Supply and fixing Fan blades fabricated to shape and size of Zink Aluminum cast alloy as per sample for electric motor with key and key grove complete all as directed for the following capacity motors :- (a) 5 HP to 7.5 HP
(b) 10 HP to 12.5 HP
Material and labour for Nitrogen leak test entire system of the AC plant of Cap upto 170 TR with Nitrogen gas. If found any leakage or reduction in the scale of pressure shall located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage permanently complete all as specified & directed.
M & L for cleaning, servicing, overhauling all component of Air cooled package/ precesion unit both indoor and out door unit by blower, water pressure jet with caustic soda solution, removing of all dust and dirt internally and externally from unit, checking of all electrical / mechanical components, topping up refrigerant if required, replacement of burnt out electrical components, calibration of PCB, insulation of suction/discharge line, cleaning of pre/micro filters, including repair of leakage by brazing of U bend, copper pipe, straightening of fins, painting of U bend with approved colour, painting of liquid line complete all as specified and directed.Note : Refrigerant gas will be issued under Sch 'B' and all other major burnt out electrical parts will be measured and paid separately under respective items of Sch.
M & L for replacement of package / precession AC out door condenser motor with fan blade assembly as per site requirement including starting / running capacitor of suitable size including control wiring, toggle switch of outdoor unit, terminal block, relay, contactor etc complete all as specified and directed.
M & L for replacement of complete dum assembly of package unit 5.5 TR with drum shaft, blower, bearing, shaft assembly, filters, complete with all electrical and mechanical work to made serviceable all as specified and directed.
Taking down carefully existing false ceiling of any type/make/size including all electric fitting/fixture, fire alarm and any other accessories etc for repair/replacement of AC duct and refixing the same in its original position with out any damage, complete all as specified and directed. Note:- If, any kind of damage occurred to false ceiling and other services like electric supply cable/fitting/fixture, fire alarm, water supply line or any other services, due to negligence or poor workmanship of contractor, the same will be repaired/replaced by the contractor free of cost and no extra payment shall be made in this effect to the contractor
M&L for cleaning of air handling ducts (GI/Al) internally by using special equipments & tools like robotic arm, air jet nozzles, flipper vaccum pump and a suction blower with hepa filter, complete all as specified and directed. Note:- Internal surface area of duct to the extent ordered and cleaned by the machinery shall only be measured and paid.
M & L for interchanging of heating /cooling coil of AHU capacity upto 25000 CFM by front, side and top panel of AHU and re-fixing of same complete with all piping arrangement as per site requirement to make functional of Chiiled water / hot water connection including re-fixing of 3 way mixing valve complete all as specified and directed.
Supply and fix in replacement of wall mounting /hanging type LED digital type temperature /relative humidity indicator alongwith (RH + Temp) duct mounting sensor/transmitter complete with 2" large size display and minimum size (445x130x115mm) with following specifications complete all as specified and as directed by Engr-in-charge :- Make : Linear Instruments, Radix, Astronic Technosystem LLP Display : 2" Red LED x 2 Display Accuracy : + 0.5% Resolution : 0.1 deg C, 0.1 % RH Input : 4-20mA Enclosure : Powder coated metal case Operating Voltage : 230V AC Display : Temperature : 0 to 55 Dec C & Relative Humidity : up to 95% RH (Non Condensing) Duct Sensor : Suitable for recording temperature/ humidity
S&F in repair for laying, jointing, connecting and testing sensor cable 3 core 2.5 sqmm PVC insulated and sheathed with bare annealed copper conductor as per IS 694:1990 for connecting RH+T sensor to RH+T indicators alongwith suitable size PVC conduit fixed on wall / ceiling / floor with suitable MS saddle complete all as specified and as directed by Engr-in-charge.
S&F in repair for laying, jointing, connecting and testing indicator cable 2 core 1.5 sqmm PVC insulated and sheathed with bare annealed copper conductor alongwith suitable size PVC conduit fixed on wall / ceiling / floor with suitable MS saddle complete all as specified and as directed.
Supplying and fixing in replacement new hermitically sealed scroll compressor 19/21 TR 3 phase 440 volt , complete with filled oil suitable for R-22/407/410 a Non CFC refrigerant gas etc including disconnecting and reconnecting with inlet and outlet refrigerant copper pipe with brazing/ soldering as required to make leak proof connection all as specified and directed. Note : 1.Referigerant Gas will be supplied by department as Sch 'B'. Transportation for gas from AGE E/M yard to site is to be provided by Contractor 2. Contractor has to produce test certificate by OEM.
Dismantling and removing old U/S compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 12.5 TR Model No SZ185S4RC of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant. Note:- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour, fixing & T & P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling the compressor the Refrigerant gas to be taken in empty cylinder by the help Ice or as directed.
Dismantling and removing old U/S compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 5.0/5.5 TR suitale for package unit of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant. Note:- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour, fixing & T & P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling the compressor the Refrigerant gas to be taken in empty cylinder by the help Ice or as directed.
Supply , installation , testing and commissioning of Y type strainer dia 65 mm cast iron body and SS screen including taking out existing unserviceable valve, replacement of suitable size gasket, nut, bolt, washer etc complete all as specified and directed.
Taking down the old unserviceable galvanized steel and design Supply, fabrication installation of air distribution system made out of (PGI sheet) galvanized steel section ducting of thickness as per Indian Standard (IS: 655-1963) including 3mm rubber gasket, nut and bolts for jointing. The supply air duct and return air duct over the ceiling with necessary inbuilt stiffeners to maintain the desired noise level from AHU to the conditioned room, of commercial grade VIII as per IS-655 including the main air chamber completely insulated with TF quality EPS sheet 50mm thick density not less than 36Kg/cum and covered with chicken wire mesh, vapour barrier PVC sheet and 10mm thick cement and plaster (where ever passes through the true wall having height more than 6 meter and same has been finished as per existing) with suitable MS supporting arrangements from floor/RCC roof/ceilings/walls with adjustable dampers, vanes, etc complete as per specification with all its accessories:-
(a) 20 Gauge
(b) 22 Gauge
(b) 24 Gauge
Taking down the old unserviceable Acoustic Insulation and supply and application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140-180Kg/cum and Class-1 Fire Performance and with antimicrobial as per ASTM E 21 using manufacturer's recommended Rubber-based Adhesive in a blend of solvents complete all as specified and directed. (The thickness of insulation 15 mm)
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet incl taking down old one complete of sizes as shown:-
(a) 40mm bore
(b) 50 mm boe
(c) 65 mm bore
M & L in repair for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet incl taking down old one complete of sizes as shown
(a) 80mm bore
(b) 100 mm boe
(c) 150 mm bore
M & L for repairs to chiller of AC plant capacity mentioned below by blocking the damage/corroded tubes involving following activities :- (i) Disconnecting the side covers fo the chiller and the chiller valves from their existing positions. (iii) Leakage testing of the chilller using pressurized nitrogen gas and finding the leakaged tubes. (iii) Blocking the damaged/leaked tubes by brass plugs. (iv) Re-fixing the side covers of the chiller and the chiller valves from their existing positions with new nuts, bolts, rubber gasket and washer. (v) Testing the system for any leakage by using pressurized nitrogen gas and by vaccumising the system. (vi) Preparing the damage surfaces of chiller as per existing including replacement of complete chiller insulation and painting of inlet / outlet pipe line with marking of direction of water flow as per existing shade for following capacities AC Plant chillers :- a) up to 25 TR Capacity
(b) 26 to 50 TR capacity
(c) 51 to 175 TR capacity
Material and labour for repairs to condenser of AC plant by blocking the damaged/corroded tubes involving following activities :- (i) Disconnecting the side covers of the condenser from their existing positions. (ii) Leakage testing of the condenser using pressurised nitrogen gas and finding the leaked tubes. (iii) Blocking the damaged/leaked tubes by brass plugs. (iv) Re-fixing the side covers of the condenser and the condenser valves from their existing positions with new nuts, bolts, rubber gasket and washers etc. and painting the surface with approved shade of synthetic enamel paints for following capacities of condenser :- (a) up to 25 TR Capacity
(b) 26 to 50 TR capacity
(c) 51 to 175 TR capacity
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping / benching /foundation etc all as specified and directed.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) for base of path/ hard standing complete all as specified and directed.
Supply and fix in replacement digital ammeter with suitable CT including connecting control wiring from CT to indicator complete all as specified and directed.
Supply and fix in replacement digital voltmeter 0-400 volts including connecting control wiring complete all as specified and directed.
Supply and fixing of canvas housing suitable for existing connection AHU/package unit outlet damper to Supply air Duct complete all as specified and directed.
Supply and fix in repairs protection caps made out of GI Sheet of thickness 1.6 mm with three GI strip supports of size 25x3mm for fixing with the Cooling Tower including GI nuts & bolts for fixing all as specified and directed.
Dismantling/Taking down old unserviceable FRP body structure of cooling tower carefully and cleaning the sump with chemical and supply and fixing of new FRP sheets as per size existing at site including all fixing material such as m seal other water resistance adhesive and making the cooling tower structure leak proof complete all as specified and directed.
Servicing & cleaning of the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dume and around the fins, cleaning of base tray & grills, pot stainer, main shaft etc. and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including painting of cooling tower with approved colour by scrapping outer sludges/paint complete all as specified and directed.
(a) cooling tower of capacity up to 35 TR
(b) cooling tower of capacity 35 TR to 75 TR
(c) cooling tower of capacity 76 TR to 200 TR
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 71 TR and above Capacity AC plant complete all as specified and directed.
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 30 to 70 TR capacity AC plants complete all as specified and directed.
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of below 30 TR capacity AC plants complete all as specified and directed.
Supply and fix in repairs cooling tower Fan Assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 50 to 175 TR capacity AC plants complete all as specified and directed.
Supply and fix in replacement of unserviceable CT fan motor 700 to 1050 RPM as per site requirement, 415 Volt + 5%, 50 HZ + 5%, 3 phase, AC Supply with ambient temperature 50 deg C, Class F insulation, IP 55 protection, continuous rated (S1 duty) capacity 2 HP with new hub and fan assembly as per site requirement complete all as specified and directed.
Supply and replacement of PVC filling blocks, drift, eliminator of size as per site suitable for cooling tower complete all as specified and directed.
Supply and fixing in repair of supply / return / exhaust air grilles /of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core complete all as specified and directed.
Supply and fix in replacement of monoblock pump set capacity 0.75 HP for humidification arrangement including connecting with existing GI pipe and connecting cable from startor to motor and suitable foundation complete all as specified and directed.
Supply and fix in replacement of perforated GI pipe 50 mm dia of required length as per size of Air handling unit complete with spray nozzle including fixing arrangement behind Air handling unit coil including connection of pipe with existing sytem for function of humidication arrangement complete all as specified and directed.
Supply and fix in replacement of drain arrangement of condensate water from AHU to outside of building by CPVC pipe SDR 11 of size not less than 50 mm dia including all accessories and connection to bottom chamber of AHU complete all as specified and directed.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 4.5 to 7.5 Amp complete all as specified and directed.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 9 to 15 Amp complete all as specified and directed.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 14 to 23 Amp complete all as specified and directed.
Supply and fix in replacement star delta electronic timer as per site, working voltage 230V 50 Hz complete all as specified and directed.
Supply and fixing in repair MCB SP 6 To 32 amp rating 240V, 10KA 'C' curve complete all as specified and directed.
Supply and fixing in repair MCB SPN 32 AMP rating 240V, 10KA 'C' curve complete all as specified and directed.
Supply and fixing in repair MCB SPN 40 to 63 AMP rating 240V, 10KA 'C' curve complete all as specified and directed.
Supply and fixing in repair MCB TP 40 To 63 AMP 415V 10KA 'C' curve complete all as specified and directed.
Supply and fixing in repair MCB TPN 6 to 32 AMP 415V 10KA 'C' curve complete all as specified and directed.
Supply and fixing in repair MCB TPN 40 to 100 AMP 415V 10KA 'C' curve complete all as specified and directed.
Supply and fix in replacement power contactor 3 pole, type MNX 12, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, complete all as specified and directed.
Supply and fix in replacement power contactor 3 pole, type MNX 18, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, complete all as specified and directed..
Supply and fix in replacement power contactor 3 pole, type MNX 22, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, complete all as specified and directed.
Supply and fix in replacement power contactor 3 pole, type MNX 32, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, complete all as specified and directed.
Supply and fix in replacement power contactor 3 pole, type MNX 40, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, complete all as specified and directed.
Material and labour for descaling of complete condenser units Quarterly for central/ package type AC plants of following capacities by means of adding descaling chemical solution (HCL) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of engineer-in-charge. (a) Central AC Plant up to 100 TR Note : Qty of descalling will be measured in each quarter at interval of not less than 90 days
(b) Central AC Plant capacity 100 TR to 200 TR
Supply and fix in replacement Phase Failure Relay with Under & Over Voltage setting (Variable), (Auto Reset 40 Volt Unbalance) complete alongwith control wiring complete all as specified and directed.
Supply and fix in replacement of Single phase preventor type SPP VSP3 3 phase, 415 Volts, 50 Hz AC complete all as specified and directed.
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp complete all as specified and directed.
Supply and fixing of Compressor protection module, 220 V AC, 50/60Hz, 2W, Ambient temperature range : 30 to 70 dec C, Relay 250 V AC suitable for scroll compressor 21 TR. complete all as specified and directed.
Supply and fixing in replacement V Belt of following sizes :- (a) V Belt B-88/89/90
(b) V Belt A-32/46
(c) V Belt B-76
Preventive maintenance & routine servicing of split/window AC of any type/size/make /model & capacity up to 3TR in any position / work shop as convenient indoor & out door unit by cleaning of dust from condenser, air filter, cooling coils by pressure pump, liquid line filter/capillary tube /expansion valve, refrigerant inlet /out let pipe by Nitrogen and Ethylene tri chloride(ETC), and checking of all electrical components and compressor etc. Replacement of minor parts such as nut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed. Note:- (i) Contractor has to provide sufficient manpower minimum 01 Technician and 02 helper daily including sunday / holidays for resolving timely complaints. (ii) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.
Supply only following items of Air conditioning split/window type AC of capacity 1.5/2/3TR of any make/model/ capacity including checking of defects and rectified. (a) Supply only in replacement with new Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC supply.
Supply only in replacement with new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC.
Supply only in replacement with new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ AC .
Supply only in replacement with new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC.
Supply only in replacement with new Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC.
Supply only in replacement with new Running capcitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC.
Supply only in replacement with new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC.
Supply only in replacement with new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unit suitable for Split AC/Window AC 1.5/2.0 TR of capacity, model and make as per existing complete all as specified and directed.
Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing.
Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR.
Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR.
Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase.
Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase.
Supply only in replacement with new Condenser side fan blade as per sample suitable for existing Split type AC's of Capacity 1.5/2 TR .
Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split AC's Non inverter type any make as existing.
Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5/2 TR capacity inverter type as per existing make and model .
Supply only in replacement with new Brass service valve of 5/8" dia with flare unit as per sample for split type AC .
Supply only in replacement with new Brass service valve of 3/8" dia with flare unit as per sample for split type AC.
Supply only in replacement with new Brass service valve of 1/2" dia with flare unit as per sample for split type AC.
Supply only in replacement with new Brass service valve of 1/4" dia with flare unit as per sample for split type AC.
Supply only in replacement with new Brass service dead nut suitable for any type of Acs as per sample.
Supply only in replacement with new copper tubing of special annealed pressure copper of size 3/8" bore
Supply only in replacement with new copper tubing of special annealed pressure copper of size 5/8" bore complete all as specified and directed.
Supply only in replacement with new copper tubing of special annealed pressure copper of size 1/4" bore complete all as specified and directed.
Supply only in replacement with new copper tubing of special annealed pressure copper of size 1/2" bore complete all as specified and directed.
Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed.
Supply and fixing in replacement with new Hermetic sealed Reciprocating compressor as per sample complete suitable for 1.5 TR Split Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under schedule A respective item complete all as specified and directed..
Supply and fixing in replacement with new Hermetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 2 TR Split Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under schedule A complete all as specified and directed.
Supply and fixing in replacement with new Hermetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 1.5 TR Single Phase Window Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under schedule A complete all as specified and directed.
Supply and fixing in replacement with new Hermetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 2 TR Single Phase Window Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under schedule A complete all as specified and directed.
Supply and fixing in replacement with new Rotary compressor as per sample complete and suitable for 1.5 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under schedule complete all as specified and directed.
Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed and suitable for 2 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under schedule A complete all as specified and directed.
Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and directed.
Supply and fixing in replacement MCB 6 to 32 Amp Single pole 10kA 'B' curve 240V, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed.
M/S Rakesh Verma (BID ID -3318421)
Uma engineers (BID ID -3311820)
lodhi builders (BID ID -3318512)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .