Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹32.0 L+₹1.9 L (6.14%)Rejected-Finance A 2 206 SAI DWARKAMAI NIBM ROAD KONDHWA PUNE 411 048 | PUNE | MAHARASHTRA | 411048 | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹32.8 L+₹2.6 L (8.78%)Rejected-Finance FLAT NO 1 179 GANESH NAGAR S NO 10 YERAWADA PUNE 411006 | PUNE | MAHARASHTRA | 411006 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹32.8 L+₹2.7 L (8.94%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹34.9 L+₹4.8 L (15.8%)Rejected-Finance AT POST SAHAJPUR RANMALA TAL DOUND DIST PUNE 412202 | PUNE | MAHARASHTRA | 412202 | L5 | Rejected-Finance RATE HIGH |
Tender Value
₹48.6 L
EMD Value
₹97,200
Closing Date
9 Jan 2024, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 411040
8493 SPECIAL REPAIR INCLUDING REPLACEMENT OF ROOF LEAKAGE SEEPAGE TREATMENT TO BLDG NO P 42 AND PROVISION OF TOILET AND URINALS UNDER AGE BR I OF GE SOUTH PUNE
2023_MES_632270_1
8493 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
180 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹97,200
Yes
11 Mar 2024
12 Dec 2023
11 Jan 2024
12 Dec 2023
9 Jan 2024
27 Dec 2023
Amount
Demolition of cement concrete in ground floor and pavings n. exc. 15 cm thickness (below or above GL) and removal of demolished materials outside the MD land, complete all as specified and directed.
Demolition of stone slabs and tiles of any description of thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
Taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water and removal of rubbished outside the MD land, complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick / stone masonary or concrete surfaces in CM 1:6, including finishing the surfaces even and smooth with out using extra cement, complete all as specified and directed.
M&L for 10 mm thick rendering on concrete surfaces of ceiling in CM 1:4, including finishing the surfaces even and smooth with out using extra cement, complete all as specified and directed.
M&L for 15 mm thick rendering on internal surfaces of PCC block/ brick / stone masonary or concrete surfaces in CM 1:6 including finishing the surfaces even and smooth with out using extra cement, complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick / stone masonary or concrete surfaces in CM 1:4, mixed with water proofing compound, including finishing the surfaces even and smooth with out using extra cement, complete all as specified and directed. Note :- WPC shall be measured & paid separately under respective item of BOQ.
Supply only lequid proofing compound, complete all as specified and directed.
Dismanling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to MES store yard and removal of rubbished outside the MD land, complete all as specified and directed.
Taking down chowkhat or frames n. exc. 1.5 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
Taking down chowkhat or frames exc. 1.5 sqm but n. exc. 4 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in bed blocks for embedding hold fasts complete all as specified and directed.
M&L for 35mm thick IInd class hard wood, glazed and skeleton shutters, open rebated and prepare to receive glass or guage etc divided into squares with plain, chamfered or rounded, mitered and rebated sash bars any number, size of members of shutters as specifie in clause 8.24(a) of SSR Part-I 2009, complete all as specified and directed.
S&F 30mm thick flush shutters, solid core contruction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&F of stainless steel Wire cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with stainless steel stapple/ wooden beads to steel or wooden windows / door / shutters / frames etc., complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection laid to slope in bays and finishing the surfaces of concrete topping fair and even and exposed edges fair or rounding or chamfering laid in panels with and including all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) complete all as specified and as directed.
M&L for RCC 1:2:4 (Nominal Mix) type B-1 using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L for form work to soffits of suspanded flat slab such as roof slabs, floor slabs, landing, shelves or column & beams and similar work exc. 200mm thick (horizontal or sloping), finished the surfaces fair, complete all as specified and directed.
M&L TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S & F TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed.
Surface excavation in soft / loose soil n.exc. 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (Using 40mm graded stone aggregate) as in sub base of floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:6 using PCC 1:3:6 type C-1 precast cement concrete blocks, complete all as specified and directed.
M&L for coloured precast cement concrete interlocking paver block of glossy finish any shape and size confirming to IS-15658-2006, 60mm thick, M-35 grade with grey cement and no pigment laid over & including 50mm thick stone dust/grit cushioning, rammed well etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole and other purpose etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance exceeding 250 m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces exc 10 cm width or girth, including preparation of surfaces, complete al as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface of any description exc. 10 cm width or girth, including preparation of new steel surfaces, complete all as specified and directed.
M & L for preparation of old decorated surfaces of ceilings and applying two coats of white wash on ceiling, complete all as specified and directed.
M & L for preparation of new decorated surfaces of ceilings and applying three coats of white wash on ceiling, complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed for following size of pipe :- (a). 15mm dia bore.
(b). 20mm dia bore.
Supplying, fixing, jointing and testing galvanised steel tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floor complete all as specified and as directed for the following sizes:- (a) 15 mm dia bore
(b). 20mm dia bore.
S&F 15 mm bore PVC connection 450 mm long with PTMT nut and PVC washer, complete all as specified and directed.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern), white, 'P' or 'S' type, including 10 litres, PVC flushing cistern, low level, white with inlet, ball valve, float & brackets, including flush pipe, PVC tube 32mm dia & including plastic water closet seat, black, closed pattern with flat bottom, cover & M S CP or aluminium hinging device, complete all as specified and directed.
S & F in repairs vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest including 10 litres, PVC flushing cistern, low level, white with inlet, ball valve, float & brackets, including flush pipe, PVC tube 32mm dia, including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with M.S square tube, supplying & fixing in opening as per specifications, drawings , complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting, of frame made out of M.S tubes for top & bottom rails M.S frame shall be covered with heat molded plain co lour PVC ‘C’ channel having a PVC sheet strip of 20mm width struck inside with solvent cement for steel & plain co lour PVC sheets for top rail, lock rail& bottom rail on either side & or gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheet banding, and joints to gather with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
S & F 100 mm long butt hinges medium weight , cold rolled Mild steel, complete all as specified and directed.
S&F 200 mm aluminium anodized barrel tower bolts of extruded section for door shutters, complete all as specified and directed.
S&F 150 mm aluminium anodized barrel tower bolts of extruded section for door shutters, complete all as specified and directed.
S & F 250 mm long aluminium alloy , anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast, complete all as specified and directed.
S&F 150 mm size aluminium handles, cast type, anodised, complete all as specified and directed.
S&F mild steel 300 mm, ordinary rat tail pattern, spring including rollar and rollar plate , complete all as specified and directed.
S&F floor door stopper, over all length of cover plate 140 mm of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in door, complete all as specified and directed.
S&F three track sliding window with two or more shutter witth 4 mm thick tinted glass, one shutter of stainless steel wire cloth 0.36 mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing, handle lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge. (a) Bottom frame 20620 (b) Top frame & Verrtical 20621 (c) Handle (side) 20606 (d) Shutter inter lock 20724 (e) Shutter top & Bottom 20844 (f) Glazing Clip 19352
S&F ventiltors/ louvers with partially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc complete all as specified and as directed. (a) SP 20048 (b) Glazing clips 19352
M&L for framed work as in grills, gratings etc. with ends of bars shouldered and / or rivetted, or forged into spikes; framed guard bars; barred iron door, railings and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed.
S&F aluminium powder coated fancy type curtain rod 25mm bore medium grade complete all as specified & directed.
S & F aluminium powder coated brackets and PVC chromium plated stops suitable for 25mm bore curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc and match with complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
M&L for Non skid ceramic colored tiles 7 to 8mm thick, (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer as in CM 1:6 complete all as specified and as directed.
M&L for coloured Ceramic tiles 450 x 300 x 7 to 8mm thick in vertical surfaces such as skirting dado set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in cement mortar 1:4 on stone / brick/ concrete masonry surfaces including triangular fitteting in CM 1:4 on top edge, complete all as specified and as directed.
M & L for vitrified glazed ceramic tiles, coloured (light shade) 15 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqmas as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed.
All as per item No. 58 above but as on vertical surfaces like skirting / Dado, laid over and including 10mm thick rendering in cement mortar 1:4 including triangular fitteting in CM 1:4 on top edge, complete all as specified and as directed.
S&F vitreous china wash hand basin, white, 550x 400mm flat back including providing CI brackets, PVC waste pipe 32mm dia, CP brass waste coupling 32mm dia with and including 15mm bore, brass CP pillar cock long body, fancy type etc complete all as specified and directed
S&F oval shape counter top wash hand basin 580mm size with front cover over flow with and including granite counter, 32mm size PVC waste pipe & coupling, 15mm bore brass CP swan neck pillar tap, complete all as specified and directed.
S&F PVC (SWR), 75mm dia outlet floor trap, plain with grating including jointing with solvent cement, fixed to cement concrete type B1 1:2:4, complete all as specified and directed.
Cutting chases, pinning in, concrete block walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting n. exc. 10 cm girth, complete all as specified and directed.
S & F 15 mm bore half turn stop valve, CP, fancy type, cast copper alloy screwed down high pressure without or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S & F 15 mm bore half turn bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F brass chromium plated health faucet, cast copper alloy including with 1.20m long ABS pipe, complete all as speicified and directed.
S&F vitreous china urinals white half stall type ( excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals against wall in cement mortar 1:2, securing urinals to plugs with and including 60 mm long brass screws pointing around urinal back in cement complete all as specified and as directed.
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe, having minimum weight 60 gms, complete all as specified and directed.
S&F stainless steel, chromium plated toilet paper holder, fixed to wall with brass screw complete all as specified and as directed.
S&F soap dish, brass chromium plated, fixed to wall with brass screw complete all as specified and as directed.
S&F shower rose chromium plated brass fancy type 125x125 mm with or without swivel any size, including fixing to steel pipe or union, complete all as specified and directed.
S&F 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints fixed to wall / trench / under floor including with all fittings & fixtures etc complete all as specified and directed.
S&F 75 mm dia PVC SWR pipes single socketed in any length with rubber ring joints fixed to wall / trench / under floor including with all fittings & fixtures etc complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends, any radius, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends, any radius, complete all as specified and directed.
S&F PVC (SWR) branch piece, 75mm bore, single (Single Y) equal or unequal, complete all as specified & directed.
S&F PVC (SWR) branch piece, 75mm bore, duble (Single Y) equal or unequal, complete all as specified & directed.
S&F PVC (SWR) branch piece, 110mm bore, single (Single Y) equal or unequal, with access door, complete all as specified & directed.
S&F PVC (SWR), 110mm bore junction with access door, single (Single Tee), equal or unequal, complete all as specified & directed.
S&F PVC (SWR), 75mm bore junction with access door, single (Single Tee), equal or unequal, complete all as specified & directed.
S&F PVC (SWR) vent cowl 75mm bore, complete all as specified & directed.
S&F PVC (SWR) vent cowl 110mm bore, complete all as specified & directed.
S&F PVC (SWR) gully trap 125x110mm, setting and jointing with solvent cement, complete all as specified and directed.
S & F in repairs 20mm bore gun metal gate valves (Class I), with iron wheel head, screwed both ends for iron pipe, ISI marked, all as specified and directed.
S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms), complete all as specified and directed.
Supply and fix in replacement rotational moulded polyethylene water storage tanks (vertical cylindrical with closed top) double layered ISI marked including connection with existing inlet, outlets & provision of washouts, vent pipe etc complete of following capacity with and including new tank nipples of suitable size / as per existing size, complete all as specified and directed. (a) 500 litres
(b) 1000 litres
M&L for complete removal of existing treatment, preparation of surfaces and applying two coats of oil bound white or tinted on walls over a coat of wall primer complete all as specified and directed
M&L for two coats of oil emulsion distemper on new surfaces of walls inlcuding preparation of surfaces of walls, complete all as specified and directed.
M&L for applying two coats cement base paint (snowcem) on new / old decorated surfaces of walls including necessary required scaffolding and preparation of new / old surface of walls, complete all as specified and directed.
S & F pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm with and including MS hold fast - 04 Nos., MS cold rolld 100mm size butt hinges- 06 Nos., welding to existing MS frame, PCC bed block 1:2:4 type B1 for embadding hold fasts and plain cement concrete 1:3:6 type C1 (12.5mm graded stone aggregate) for filling in MS frame, complete all as specified & directed.
S & F pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 105 x 60mm with and including MS hold fast - 04 Nos., MS cold rolld 100mm size butt hinges- 03 Nos., welding to existing MS frame, PCC bed block 1:2:4 type B1 for embadding hold fasts and plain cement concrete 1:3:6 type C1 (12.5mm graded stone aggregate) for filling in MS frame, complete all as specified & directed.
M&L for mirror polished machine cut kota stone slab as in tread & steps in single piece, 20-25 mm thick including 3x3mm size two number of grooves, laid over and including cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 10mm thick screed bed in cement mortar 1:4 complete all as specified and as directed
All as per item No. 93 herein before but without grooves as on vertical surfaces such as dado / skirting etc. laid over and including 10mm thick rendering in CM (1:4) complete all as specified and directed
M&L for machine cut kota stone slab as in flooring, 20-25 mm thick laid pointed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
M & L for granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick in steps, jambs, pillars, window cill, cooking platform and flooring in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick in CM 1:6 on stone masonry surfaces, complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, shelf cooking platform, and other similar situations, complete all as specifed and directed.
S&F brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
M&L for water proofing treatment to sunken slab, walls etc. shall be carried out with and including the following provisions as specified below and as directed by Engineer-in-Charge:- (a) M&L for 15mm thick plaster/screed bed layer in cement mortar (1:3) on concrete surfaces and using extra cement mixed with including approved make of WPC @ 3% by weight of cement. (b). Preparing plastered surfaces of sunken slab, walls, etc, by brooming with broom sweeping free from dirt dust etc & provide form angle fillet of size 40mm x40mm along the junction of wall and floor by using polymer modified mortar of “Dr fixit” Pidicrete URP” or equivalent as approved. (c). Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bathseal Tape” and the gaps to be grouted with non-shrink cementitious grout of “Dr Fixit Bathseal Grout” or equivalent as approved. Nahani traps etc to be fitted securely and the gaps around it to be grouting in the same manner complete all as directed by Engr-in-Charge.
(d) Apply one coat of a Bitumen-modified polymer coating of “Dr Fixit Bathseal Plus” or equivalent on all angle fillets by brush and cover it with 1.8mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating up to 150mm above the FFL. Above FFL, another cementitious waterproofing coating of “Dr Fixit Pidifin 2K” or equivalent as approved be further applied right up to 2.1m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.
(f). After 2 to 3 days, sunken portion must be overlaid with 50 mm thick concrete screed M-15 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40mm OD UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2. (Note :- Lean concrete will be measured and paid separately) (g). Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of Engr-in-charge.
Removing of old unserviceable water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc. 500m outside defence land complete all as directed by Engr-in-Charge.
M & L for water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out by providing the following provisions etc , complete all as specified and directed by Engineer-in-Charge. (a) M&L for providing 10mm thick plaster screed bed layer in CM (1:3) on concrete surfaces by using ready mix plaster. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 Kg/sqm. (c) M&L for laying APP polymer modified approved membrane, non-woven, polyester, weighing not less than 3.5 Kg/sqm with laps & overlaps as directed & joints sealed and applied complete by torch application method and on completion of roof treatment, carrying out test by flooding water on roof for 24 hrs for leakage & seepages. If any leakage / seepages observed after water proofing test the same be rectified to the entire satisfaction of Engr-in-Charge. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 litre /sqm on the top of membrane surfaces.
M&L for PCC 1:5:10 type E-2 (Using 40mm graded brick aggregate) as in sub base of flooring of toilets, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
Taking down point wiring( light, fan, socket or power) any type complete, including fixtures and fittings such as switches, ceiling roses, pendants,regulators sockets, loght fitting etc removing materials to store for keeping in safe custody for taking on credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Taking down old unserviceable / worn out aluminium sub main of any type and size, complete all as specified and directed.
Taking down old unserviceable /worn out DB,s any type and size, complete all as specified and directed.
M & L for Point wiring with colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- Cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable Make:- Finolex/polycab/ Havell's drawn through in and including heavy duty PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, incl making good of disturbed surface and finish with two coats of white / colour washing / distempering etc to match the existing surface complete etc heavy duty ISI marked, with GI sunken boxes with earth dolly including with 3mm thick plastic laminated sheet top cover of approved make and colour including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly etc complete all as specified and directed for the following :- (a) One light/fan / exhaust fan point controlled by one, one way switch
(b) Switch socket outlet point controlled by one switch on independent boad
(C) One switch socket outlet, three pin 5 amps on the same board
(d) One light point controlled by two, two way switch
Description all as per item No.110 above but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly etc complete all as specified and directed.
Description all as per item No.110 above but using 4 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly etc complete all as specified and directed.
S&F fan regulator electronic rotary, step flush type, 120/280 volts, 50 Hz, complete all as specified and as directed.
S & F sheet metal enclosure double door suitable for distribution boards when MCB to be used having 200 Amp rated bus bar SPN 12 ways 230 V, concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including applying two coats of white / colour washing / distempering etc on disturbed surfaces to match the existing, complete all as specified and as directed.
S & F sheet metal enclosure double door suitable for distribution boards when MCB to be used having 200 Amp rated bus bar SPN 8 ways 230 V, concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including applying two coats of white / colour washing / distempering etc on disturbed surfaces to match the existing, complete all as specified and as directed.
S & F sheet metal enclosure double door suitable for distribution boards when MCB to be used having 200 Amp rated bus bar TPN 4 ways 415 V, concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including applying two coats of white / colour washing / distempering etc on disturbed surfaces to match the existing, complete all as specified and as directed.
S & F sheet metal enclosure double door suitable for distribution boards when MCB to be used having 200 Amp rated bus bar SPN 4 ways 230 V, concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including applying two coats of white / colour washing / distempering etc on disturbed surfaces to match the existing, complete all as specified and as directed.
S & F sheet metal enclosure double door suitable for distribution boards when MCB to be used having 200 Amp rated bus bar TPN, 4 ways 415 V with and including provision of MCCB, TP, 160 Amps as incomer and SP/TP MCBs as outgoing, concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including applying two coats of white / colour washing / distempering etc on disturbed surfaces to match the existing, complete all as specified and as directed.
S&F MCB SP 6-32 Amps, 10KA, 240 volts, 'C' series, complete all as specified directed.
S&F MCB SPN 32 Amps, 10KA, 240 volts, 'C' series, complete all as specified directed.
S&F MCB SPN 10-40 amps,10KA, 240V,'C' series, complete all as specified directed.
S&F MCB TPN 63 Amps,10KA, 415V, 'C' series, complete all as specified and as directed.
S&F MCB TPN 25-63 Amps,10KA, 415V, 'C' series, complete all as specified and as directed.
S&F MCB SPN 40-63 Amps,10KA, 240 volts, 'C' series, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of 4 mm dia earth wire & light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earth wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of necessary earth excavation & work and 7.50 m 15mm bore GI pipe for protection of 4mm dia GI earth wire for each earthing.
M & L for 4mm dia GI wire as in earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe, complete all as specified and directed.
Supply and fixing LED light fitting,1X20 Watt surface mounted LED high efficiency LED luminare smart bright ingress protection : IP66 with acrylic cover comprises pre-wired with high efficiency electronic driver,high trnslucent frosted diffuser gets glare free, smooth light distribution, complete all as specified and directed. Make:- Philips cat No-BN021C LED20S PSU NW GR OR equivalent cat part in Wipro / Bajaj.
S&F LED street light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment incuding with 1.50m long GI pipe, medium grade of suitable dia including with fitting and fixtures on wall complete with all accessories, complete all as specified and directed by Engr-in-charge. Make- Luker LSTE-30/ Havells ENDURA CITY LITE PLAT PLUSSL30WLED757SASYBOPC / Wipro LR02-331-XXX-57-XX
Supply, laying, testing of 1100 volts grade heavy duty, 16 sq mm 2 core under ground cable, XLPE insulated, aluminium stranded conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape, fixed on pole / wall / trenches including making cable connection with required connecting material, complete all as specified and as directed.
Supply and laying 20mm bore GI pipe, medium grade, laid in trenches including all fittings and fixtures etc complete all as specified and directed.
M&L for Cutting existing 40 to 50mm bore GI tubing for alterations or additions (Each cut measured), complete all as specified and directed.
M&L for screwing in existing 40 to 50mm bore GI tubing for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and directed.
M & L for laying of dry, clean fine sand as in cushion or filling in trenches around underground cable, in ducts, inside sub station complete all as specified and directed.
Supply and fix steel body exhaust fan, noise free, AC single phase 230/ 240 volts of size 300 mm sweep, with blades, louvers including all fixing arrangements, complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core 4 sqmm (FRLS), 1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of one single core 4 sqmm (FRLS) drawn in to and including concealed PVC non metalic rigid heavy duty PVC conduit pipe & accessories including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge. Note: (i) Two runs of 4 sqmm cable and one run of 4 sqmm cable of earth continuity conductor and one run of PVC conduit of suitable dia shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core 6 sqmm (FRLS), 1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of one single core 6 sqmm (FRLS) drawn in to and including concealed PVC non metalic rigid heavy duty PVC conduit pipe & accessories including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge. Note: (i) Two runs of 6 sqmm cable and one run of 6 sqmm cable of earth continuity conductor and one run of PVC conduit of suitable dia shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core 10 sqmm (FRLS), 1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of two single core 10 sqmm (FRLS) drawn in to and including concealed PVC non metalic rigid heavy duty PVC conduit pipe & accessories including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge. Note: (i) Four runs of 10 sqmm cable and two run of 10 sqmm cable of earth continuity conductor and one run of PVC conduit of suitable dia shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core 16 sqmm (FRLS), 1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of two single core 16 sqmm (FRLS) drawn in to and including concealed PVC non metalic rigid heavy duty PVC conduit pipe & accessories including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge. Note: (i) Four runs of 16 sqmm cable and two run of 16 sqmm cable of earth continuity conductor and one run of PVC conduit of suitable dia shall be measured as one unit length.
S & F switch piano flush button type 6 Amp single pole one way complete all as specified and as directed.
S & F switch piano flush button type 15 Amp single pole two way complete all as specified and as directed.
S & F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S & F socket outlet 2 in 1, 3/6 pin, 5 Amp and 15 Amp multipurpose flush type complete all as specified and as directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminals complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 250mm x 150mm x 40mm, complete all as specified and as directed.
S & F Lamp holder, PVC / Urea type with back plate suitable for batten fittings complete all as specified as directed
S & F in repairs socket outlet 2 in 1, 3/6 pin, 5 Amp and 15 Amp multipurpose flush type complete all as specified and as directed.
S&F LED bulk head light fitting 10 watts, die cast aluminium housing with complete assembly and PC opal diffuser suitable for indoor & outdoor applications with IP-65 protection, complete all as specified and directed.
SARATH ENTERPRISES
TULSAYA CONSTRUCTION
Gauri Associates
M/S Abhishek Builders
SUJATA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .