Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹37.1 L+₹33,282.90 (0.91%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.5 L+₹1.7 L (4.73%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹39.4 L+₹2.6 L (7.10%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹41.6 L+₹4.9 L (13.3%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹42.3 L
EMD Value
₹84,600
Closing Date
20 Dec 2023, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME SECUNDERABAD MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500 015
SPL REPAIR TO PERIMETER BOUNDARY WALL AT CTW AND PROVN OF ADDL ELECT FITMENT IN CERTAIN BLDGS IN MCEME SECUNDERABAD UNDER GE MCEME SECUNDERABAD
2023_MES_629784_1
GE/MCEME/TOK/32 OF 2023-24
Open Tender
Civil Works
Works
180 days
GE MCEME SECUNDERABAD
Class D category a(i)
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹84,600
Yes
8 Jan 2024
24 Nov 2023
23 Dec 2023
24 Nov 2023
20 Dec 2023
8 Dec 2023
Amount
Demoltion of cement Concrete of any description and in any position not otherwise specifically provided, complete all as specificed and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description and in any position not otherwise provided for, complete all as specificed and directed by Engineer-in-Charge.
DismantlING plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specificed and directed by Engineer-in-Charge.
Demolition of brick work /stone boulder of any description and in any position not othterwise specifically provided for, complete all as specificed and directed by Engineer-in-Charge.
M&L for brick work with fly ash, bricks straight or curved on plan exc 6m mean radius built in Cement Mortar 1:6, complete all as specificed and directed by Engineer-in-Charge.
M&L rendering 15mm thick on stone masonry surfaces or surface other than fair face of brick-work in cement mortar 1:6 and finishing the surface even and smooth without using extra cement complete all as specificed and directed by Engineer-in-Charge.
M&L for preparation of newely plasted surfaces of walls and applying two coats of cement base paint over and including a coat of alkali resistant paint, complete all as specificed and directed by Engineer-in-Charge.
M&L for Cement concrete type B- 0, 1:2:4 (12.5mm graded stone aggregate) for coping or chamfered on edges, complete all as specificed and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C2( using 40mm graded stone agg) as in foundation, filling and mass concrete etc. complete all as specificed and directed by Engineer-in-Charge.
M&L Rolled mild steel sections Fe 410-W (Gde E-250) Quality A as in framing for clading, glasing and the like fixed with angle cleats and connecteing plates etc complete all as specificed and directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminium zinc GI based profile pattern steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engieneer- in Charge.
Supply and Fix in repair Glavanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured) all as specified and directed by Engineer-in-Charge
Supply and fix concertina coil fencing with punched tape concertina coil 900mm dia having 50 Nos rounds per 6 metre length, up to 2.50m height of wall on angle iron Y-shaped bracket placed 2.40m to 3.00m apart and horizontal barbed wire, stud tied with G.I staples and G.I clips to retain horizontal, etc with reinforced barbed tape/spring core (2.5mm thick) wire of high tensile strength of 165kg/sqmm with tape (0.52 mm thick) and weight not less than 43.478 gm/metre, all as specified and directed by Engineer-in-Charge. Note:- Y angle iron bracket and horizontal barbed wire will be measured and paid separately.
Supply and fix concertina coil fencing with punched tape concertina coil 600mm dia having 50 Nos rounds per 6 metre length, up to 2.50m height of wall on angle iron Y-shaped bracket placed 2.40m to 3.00m apart and horizontal barbed wire, stud tied with G.I staples and G.I clips to retain horizontal, etc with reinforced barbed tape/spring core (2.5mm thick) wire of high tensile strength of 165kg/sqmm with tape (0.52 mm thick) and weight not less than 43.478 gm/metre, all as specified and directed by Engineer-in-Charge. Note:- Y angle iron bracket and horizontal barbed wire will be measured and paid separately.
M&L for preparation of old decorated surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying one coat of cement base paint , complete all as specified and directed by Engr-in-Charge. (Note : Work to be carried out from ground floor to fourth floor of bldg height)
M & L for Point wiring on concealed conduit with 1.5 Sq mm copper conductor single core PVC insulated unsheathed 1100 V grade multistranded drawn into and including rigid PVC conduit with accessories of suitable dia medium grade concealed in walls/floors and pressed steel terminal boxes MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including one running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specificed and directed by Engineer-in-Charge. (a) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
S & F Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specificed and directed by Engineer-in-Charge.
S & fixing Socket outlet 3 pin, 5A, flush type complete all as specificed and directed by Engineer-in-Charge.
M & L Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through concealed and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 32 mm dia including two run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
Taking down existing (450 Mtr) fence controlled GI/Aluminium wiring insulators, intermediate security post, End post assembly 1.3m, concealed fence configeration link bus bars made of 12SWG HT wire, solar module mounting arrangement pole with mounting structure and connected accesories complete including fixture and fittings such as cable, pipes and solar panels etc. Removing material to store for keeping in safe custody or for taking credit( Credit for above items shall be made as per Sch of Credit)
Supply and fixing MCB SP 6 to 32 Amps C curve, 240 volts for fixing on MCB DB complete all as specificed and directed by Engineer-in-Charge.
GNV Engg Services
VACON INFRASTRUCTURES
Vipin Kumar and Brother
Vara Enterprises
SAI RUPA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .