| 3 | L3₹22.7 L+₹1.9 L (9.23%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹28.5 L+₹7.8 L (37.5%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
1 Jun 2022, 6:00 pmClosed
GE South Delhi Cantt
Garrison Engineer South Delhi Cantt 110010
REPAIR/REPLACEMENT OF OLD UNSERVICEABLE WIRING AND CONNECTED FITTINGS AND FIXTURES AT MANESAR, DUNDAHERA AND KHANPUR ARMY CAMP, REPAIR/REPLACEMENT OF CEILING FANS, EXHAUST FANS AND SUMMER/WINTER APPLIANCES WITH CONNECTED ITEMS AT VRC 10 JAK LI, DGIS,
2022_MES_519890_1
GE/DS-21/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹81,000
18 Jun 2022
25 Apr 2022
3 Jun 2022
25 Apr 2022
1 Jun 2022
9 May 2022
Amount
Taking down of ceiling fan/ exhaust fan/wall mount fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and directed by Engineer-in-Charge. Note:- Rewinding will be measured and paid separately.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush, ball bearing where ever required complete all as specified and directed by Engineer-in-Charge. Note : Gun metal bush, clamp, shaft, rod, bearing shall be measured and paid separately
All as per item No 2 above but Ceiling fan 14000 mm sweep.
All as per item No 2 but here-in-before exhaust fan 450 mm sweep.
All as per item No 2 but here-in-before exhaust fan 230/300 mm sweep.
All as per item No 2 but here-in-before wall mount fan 200/300 mm sweep.
All as per item No 2 but here-in-before wall mount fan 400 mm sweep.
S&F in replacement of upper and lower Gun metal bush for ceiling fans as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement wall mount bush upto 400mm sweep of suitable size & model as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement wall mount shaft upto 400mm sweep with pin of suitable size & model as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ceiling fan Ball bearing of suitable size & model as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fan shaft with pin for ceiling fans of 1200/1400mm sweep as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement U clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Down rod of 1.5 feet height fabricated out of MS pipe 12mm dia heavy duty, duly painted with one coat of white synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Canopy of Ceiling fans of 1200/1400mm swipe heavy duty complete all as specified and directed by Engineer-in-Charge.
S&F in replacement blade (set of 3 blades) of Ceiling fans 1200/1400mm swipe heavy duty as per sample complete all as specified and as directed by Engr-in-Charge.
S&F in replacement blade of exhaust/fresh air fans of 230/300 mm swipe heavy duty as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement blade of exhaust/fresh air fans of 450 mm swipe heavy duty duly as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Exhaust fan MS Louvers upto 450 mm Size, as per sample up to fourth floor complete all as specified and directed by Engineer-in-Charge. Note:-Staircase arrangement for fixing of louvers up to fourth floor shall be arranged by the contractor without any extra cost.
S&F in replacement of single phase inducation motor AC 230V, 1300 RPM copper wounded suitable for fresh air fan 200mm sweep as per sample, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of single phase inducation motor AC 230V, 1350 RPM copper wounded suitable for fresh air fan 300mm sweep as per sample, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of single phase inducation motor AC 230V, 1500 RPM copper wounded suitable for fresh air fan 450mm sweep as per sample, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of single phase inducation motor AC 230V, 1400 RPM copper wounded suitable for wall mount fan upto 450 mm sweep as per sample, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of ceiling fan capacitor of 2.5 mfd complete all as specified and directed by Engr-in-Charge. Make : TIBCON/AE/ EPCOS/Havells
S&F in replacement of ceiling fan capacitor of 3.5 mfd complete all as specified and directed by Engr-in-Charge. Make : TIBCON/AE/ EPCOS/Havells
S&F in replacement of wall mounted fan capacitor 2/2.5 MFD upto 400 mm swip size as per sample complete all as specified and directed by Engr-in-Charge. Make : TIBCON/AE/EPCOS/Havells
S&F in replacement for fan regulator electronic, stepped type/switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engr-in-Charge.
Dismantling, collecting and transporting of desert coolers from MES store yard/user bldgs to work shop and overhauling of fan motar, oiling to vertical pump including replacement of unserviceable bolts and nuts with washers, clamps etc.complete and returning back to MES store yard/user locations complete all as specified and directed. Note: Parts except nut/bolt/washers to be replaced and be measured & paid separately under respective items.
S&F in repair submersible water lifting pump,single phase suitable for desert coolers complete all as specified and directed by Engr-in-Charge. Make : Turbo/vijay / Hindustan/Meghdoot /Sumerking.
S&F in repair fan motor of desert cooler upto 1 HP, 230 volt, 50Hz cycles as per sample complete all as specified and directed by Engr-in-Charge. Make : Summer Cool Hindustan /Havells.
S&F in repair capacitor, 4 mfd rating complete all as specified and directed by Engr-in-Charge. Make : Asian/Univarsal.
S&F in repair MS fan blade of size 300/450 mm seep suitable for desert coolers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of plug top, 5 Amps, 230 Volts, 50 Hz, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC pipe, heavy duty of 15mm bore as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in repair wood wool pad (set of 3) size 95x95 cm of as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement side Panels made with 2mm thick MS sheet as per existing size and sample for desert cooler complete all as specified and directed by Engineer-in-Charge.
S&F in repair relay assembly suitable for water cooler capacity upto 120 Ltrs complete all as specified and directed by Engineer-in-Charge. Make : Shri Ram/Usha/Voltas or Blue Star.
S&F in repair over load protector for water cooler of capacity upto 180 Ltr as per sample complete all as specified and as directed by Engr-in-Charge. Make : Shri Ram/Renutral/Microtech.
S&F in repair starting capacitor for water cooler of capacity upto 150 Ltr as per sample complete all as specified and as directed by Engr-in-Charge. Make : Usha/Taslla/Universal.
S&F in repair running capacitor for water cooler of capacity upto 150 Ltr as per sample complete all as specified and as directed by Engr-in-Charge. Make : EPCOS/Asian.
S&F Thermostatic switch for water ccoler of capaicty upto 150 Ltrs as per sample complete all as specified and directed by Engr-in-Charge. Make : Indfoss or its equivalent as sample approved by Engr-in-Charge.
S&F in repair of regulator for water coolers as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP bib tap for water coolers as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in repair float valve of 15mm brass including complete assembly for water coolers as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in repair chromium plated push cock, self closing, spring loaded type 15mm dia with water waste tray for water coolers complete all as specified and directed by Engineer-in-Charge.
S&F blower motor as per sample for water cooler, commissioning and testing complete all as specified and directed by Engineer-in-Charge.
M&L complete servicing of water cooler by cleanning of coils with caustic soda, removal of rust from sheet metal frame, cleaning of tank and checking of water connection and fixing in original position complete all as specified and directed by Engineer-in-Charge.
M&L for detecting the gas leakage, rectifying the defects vacumizing and charging fresh Gas and commissioning and testing the Water cooler of 120 Liters Capacity complete all as specified and directed by Engineer-in-Charge.
M&L for detecting the gas leakage, rectifying the defects vacumizing and charging fresh Gas and commissioning and testing the Deep Freezer of 425 Ltr capacity complete all as specified and directed by Engineer-in-Charge.
Supply, fixing & testing fan blade of motor for Water Cooler of 120 Ltrs Capacity including removing old fan blade complete all as specified and directed by Engineer-in-Charge. (As per sample of the existing water cooler blade).
S&F flexible PVC insulated 3 core 4 Sqmm with copper conductor cable suitable for indoor unit to outdoor unit for deep freezer/water cooler complete all as specified and directed by Engineer-in-Charge.
S&F PVC Pipe brass nipple 15 mm x 600 mm for Hot & Cold water with brass nuts and washers stainless steel at both ends of length not exc. 60 cms for connection of stainless steel as per sample complete all as specified and directed by Engineer-in-Charge.
Taking down carefully the old U/S Aluminium point wiring (light, fan) complete fitting (such as switches, socket, ceiling rose, fan regulators, holder etc) and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including suitable concealed PVC conduit medium grade and sunk in pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer complete with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified. (One light/fan/bell point controlled by one way switch) Note :- The Rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 and same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash complete.
All as per Srl item No. 54 above but one 3 pin socket outlet 5/6 Amps on same board.
All as per Srl item No.54 above but one socket outlet 5/6 Amps on independent board.
All as per Srl item No.54 above but one power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 1.5 sqmm.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable on new PVC conduit on surface with CI/pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required color with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and directed by Engr-in-Charge. One light /fan point controlled by one way switch
All as per Srl item No.58 above but one 3 pin socket outlet 5 amps independent board
All as per Srl item No.58 abve but one 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 1.5 sqmm as earth wire as power point.
S&F switch piano flush type 6 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of heating element of 2.0 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) or as per sample for 35/50 litre capacity geysers with collar, duly tested at required pressurecomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement of storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) or as per sample for 25 litre capacity geysers with collar, duly tested at required pressurecomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement of insulating material (Glass wool) for 25/35/50 litre capacity Geysers as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MS base plate assembly 20 SWG heavy duty suitable for 35/50 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site As per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MS base plate assembly 20 SWG heavy duty suitable for 25 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of safety plug and nut for high pressure release As per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of non return valves 15mm dia made up of brass as per sample complete all as specified and directed by Engineer-in-Charge
S&F in replacement of MS top & bottom cover for geysers of 25/35/50 ltrs capacity any make as per sample duly painted with two coats of Synthetic enamel spray paint (first quality) and write down the MES number as per existing complete all as specified and directed by Engineer-in-Charge
S&F in replacement of MS outer cover for geyser made out of MS sheet suitable for upto 50 ltrs capacity geyser vertical/horizontal type complete all as specified and directed by Engineer-in-Charge
S&F in replacement of geyser syphon assembly set complete with inlet, outlet and thermostat including rubber gasket for geyser of 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat 9/11" (ISI Marked) for 25/35/50 Litres capacity Geyser as per sample complete all as specified and directed by Engineer-in-Charge
S&F in replacement of indicator lamp (Red & Green) 230 volts suitable for Geyser as per sample complete all as specified and directed by Engineer-in-Charge
S&F socket piano, flush type 5 Amps single pole one way, complete all as specified and directed by Engr-in-Charge.
S&F switch piano, flush type 15 Amps single pole one way, complete all as specified and directed by Engr-in-Charge.
S&F socket piano, flush type 15 Amps single pole one way, complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface Bakelite 60x 25 mm two to three terminals, complete all as specified and directed by Engr-in-Charge.
S&F ceiling fan regulator electronic socket type complete all as specified and directed by Engr-in-Charge.
S&F for Batten holder with PVC body and back plate suitable for LED Bulb B-22 cap complete all as specified and directed by Engr-in-Charge.
S&F LED RETROFIT Lamp of 12 watt for fixing in batten holder point complete all as specified and directed by Engr-in-Charge.
S&F LED Integrated Batten T-5, 20 Watt, 4 Ft White, indoor decorative aluminium extruded T5 LED battern-integrated type complete with including fliexble in replacement of old unsv existing 36 Watt tube light fitting complete all as specified and directed by Engr-in-Charge.
S&F LED Integrated Batten T5 LED tube light fitting of 10 Watt - 2' white, indoor decorative aluminium extruded T5 LED battern integrated type complete with including fliexble wire in replacement of old unsv existing 36 Watt tube light fitting complete all as specified and directed by Engr-in-Charge.
S&F of LED Security light fitting 45 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt, anchor fastner washer etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 2x2 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified and directed by Engr-in-Charge.
M&L for in repair submain wiring of two runs of 6 Sqmm size for main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engr-in-Charge.
S&F in replacement of distribution board triple pole and neutral 4 way double door suitable for fixing MCCB up to 125 Amps as incomer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified and directed by Engr-in-Charge.
S&F MCCB 125 Amp 3 pole, 415 C, 36 kA in replacement old unsv isolator any type complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal enclousure for DB's where MCB's to be used Single pole and Neutral 12 way, 240 volts, double door bus bar neutral link, earth bar and din rail complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal enclousure for DB's where MCB's to be used Single pole and Neutral 08 way, 240 volts, double door bus bar neutral link,earth bar and din rail complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal enclousure for DB's where MCB's to be used Single pole and Neutral 04 way, 240 volts, double door bus bar neutral link,earth bar and din rail complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SPN 32/40 Amps 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SP 6 to 32 Amps 240 volts complete all as specified and directed by Engr-in-Charge.
M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as specified and directed by Engr-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/s Adhikari construction co.
Chaudhary Constructions
Shiv Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .