Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC NEAR OLD INDIAN OIL DEPOT JALANDHAR JAMMU BYE PASS ROAD PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.0 L+₹2.5 L (21.8%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest | |
| 3 | L3₹14.8 L+₹3.3 L (29.0%)Rejected-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC 3rd lowest | |
| 4 | L4₹15.5 L+₹4.0 L (34.9%)Rejected-AOC | L4 | Rejected-AOC 4th lowest |
| Sl No | Description | Qty | Unit | Malpotra Enterprises L4 | M/S ANSHUL ENTERPRISES L1 | M/S CANTILEVER ENGINEERS L3 | bhatia construction L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. | 1,046 | Per Point | 10 ₹10,460 | 1 ₹1,046 Lowest | 5 ₹5,230 | 35 ₹36,610 |
| 2.00 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.2mm thick and connected to common earth dolly with 1.2mm thick steel pressed steel sunken box of adequate size and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. | 30 | Per Point | 450 ₹13,500 | 550 ₹16,500 | 400 ₹12,000 Lowest | 650 ₹19,500 |
| 3.00 | All as per Ser item No 2 here-in-before but for one 5/6 Amp socket outlet point on same board controlled by one switch. | 10 | Per Point | 250 ₹2,500 | 150 ₹1,500 Lowest | 200 ₹2,000 | 390 ₹3,900 |
| 4.00 | All as per Ser item No 2 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. | 10 | Per Point | 420 ₹4,200 | 550 ₹5,500 | 400 ₹4,000 Lowest | 650 ₹6,500 |
| 5.00 | All as per Srl item No 2 here-in-before but for one 15/16 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. | 10 | Per Point | 590 ₹5,900 | 600 ₹6,000 | 500 ₹5,000 Lowest | 800 ₹8,000 |
| 6.00 | All as per Ser item No 2 here-in-before but for one light point controlled by two 2 way switch, 5/6 Amp, 240 volts. | 1 | Per Point | 510 ₹510 | 600 ₹600 | 450 ₹450 Lowest | 690 ₹690 |
| 7.00 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through exisitng PVC conduit and connected to common earth dolly with 1.2mm thick steel pressed steel sunken box of adequate size and 3mm thick plastic laminated sheet cover with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. | 68 | Per Point | 450 ₹30,600 | 500 ₹34,000 | 400 ₹27,200 Lowest | 590 ₹40,120 |
| 8.00 | All as per Ser item No 7 here-in-before but for one light point controlled by two 2 way switch, 5/6 Amp, 240 volts. | 1 | Per Point | 600 ₹600 | 600 ₹600 | 400 ₹400 Lowest | 800 ₹800 |
| 9.00 | All as per Ser item No 7 here-in-before but for one 5/6 Amp socket outlet point on same board controlled by one switch. | 20 | Per Point | 250 ₹5,000 | 100 ₹2,000 Lowest | 400 ₹8,000 | 120 ₹2,400 |
| 10.00 | All as per Ser item No 7 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. | 20 | Per Point | 500 ₹10,000 | 500 ₹10,000 | 400 ₹8,000 Lowest | 524 ₹10,480 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Jun 2026, 6:00 pmClosed
Garrison Engineer (North) Mamun
Garrison Engineer (North) Mamun Pathankot-145001
COMPREHENSIVE MAINTENANCE OF INTERNAL ELECTRIFICATION AT OFFRS ACCN UNDER AGE E/M-I OF GE (N) MAMUN
2026_MES_765858_1
GE(N)/M-06/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (North) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (North) Mamun
₹40,000
23 Jul 2026
16 May 2026
13 Jun 2026
16 May 2026
6 Jun 2026
30 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. | 1,046 | Per Point | - | - |
| 2 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.2mm thick and connected to common earth dolly with 1.2mm thick steel pressed steel sunken box of adequate size and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. | 30 | Per Point | - | - |
| 3 | All as per Ser item No 2 here-in-before but for one 5/6 Amp socket outlet point on same board controlled by one switch. | 10 | Per Point | - | - |
| 4 | All as per Ser item No 2 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. | 10 | Per Point | - | - |
| 5 | All as per Srl item No 2 here-in-before but for one 15/16 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. | 10 | Per Point | - | - |
| 6 | All as per Ser item No 2 here-in-before but for one light point controlled by two 2 way switch, 5/6 Amp, 240 volts. | 1 | Per Point | - | - |
| 7 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through exisitng PVC conduit and connected to common earth dolly with 1.2mm thick steel pressed steel sunken box of adequate size and 3mm thick plastic laminated sheet cover with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. | 68 | Per Point | - | - |
| 8 | All as per Ser item No 7 here-in-before but for one light point controlled by two 2 way switch, 5/6 Amp, 240 volts. | 1 | Per Point | - | - |
| 9 | All as per Ser item No 7 here-in-before but for one 5/6 Amp socket outlet point on same board controlled by one switch. | 20 | Per Point | - | - |
| 10 | All as per Ser item No 7 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. | 20 | Per Point | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_857735.xls
BOQ • 0.33 MB
Tender06.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .