SUPERINTENDING ENGINEER
33/11KV SUB STATION PURANIA ALIGANJ LUCKNOW
Bifurcation of existing 11 KV Bataha Feeder in to New 11 KV Gulachin feeder against Business Plan sanctioned Packages No- 114/2020-21 to avoid overloading of sector-1,11,12,13,14 Vinayak Puram, Anand puram, emanating from Vikas Nagar S/S
2021_MVVNL_562922_1
83/EUDC-X/2020-21
Open Tender
Electrical Works
Lump-sum
180 days
EDD RAHIM NAGAR LESA LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE EDD BKT LESA LUCKNOW
₹12,900
20 Mar 2021
4 Mar 2021
12 Mar 2021
4 Mar 2021
10 Mar 2021
4 Mar 2021
180 days
Amount
Loading, carriage & unloading of following materials from centre store Daliganj to work site and its stacking. Distance approx (0-50) kms.
(b) STP Pole 9/11 Mtr. long.
(c)ACSR Rabit/Dog /Racoon/weasel/ conductor
d) 11 KV XLPE Cable (3x35/70/120/150/185)sqmm
(e) 11 KV O/G panel with V.C.B. CTR 200/100 5A
(g) 11 KV 3X185 XLPE Outdoor Box
(h) 11 KV 3X185 XLPE Indoor Box
(i) 11 KV 3X185 XLPE Straight through Box
(o) MS Channel 100X50X6 mm
(p) MS Angle 75X75X6 mm
Fabrication & erection of 11 KV Exposure type double pole on 11 Mtr long STP with providing & fixing of MS top channel of size 100x50mm (2240mm long) & one no dropper channel (100X50X6) & xross bracing angle of size (65X65X6) necessary clamps,& Accessories required .
Errction of 11 KV bus-bar on 11 Mtr long ST Pole with providing & fixing of 02 Nos T-off channel, 11 KV pin insulator & single core cable with the help of accessories required.
Laying of 11 KV XLPE (3x35/70/120/150/185) sqmm double cable in pakka road manual method as per RESPO specification & direction of E/I.
proper laying of cable one by one through new trench & pulling of cable up to out going pannel in control room.
Proper reconnetion of 11 KV out going cable to CT contect & proper taping of HT & impire tap.
Ordinary earthing by MS earth Rod 2500mm long as per RESPO Schedule. Only GI wire& Earth rod shall be supplied by the department.
Digging of pit of size 3X2X 1 mtr for making straight through joint 11 KV work included filling of soil leaveling and ramming of the same (S/TH provided by department).
Installation and commissioning of New 11 KV O/G panel with V.C.B. CTR 200/100 5A including connecting with Bus Bar and O/G cable. Toping of H.T. tope and testing of complete breaker and enrizating of panel.
Hoisting of 11 KV XLPE Cable will be passed through MS pipe of required size duly clamped with pole at the bottom, middle and top of the pole.
Painting of STP Pole of two coat red oxice paint.
Earthing of pannel with MS flat of size 50X50X6 mm
Matching of 11 KV Bus bar of new 11 KV outgoing pannel with existing pannel rack with all required assosiries.
Installation root marker on root of 11 KV under ground line.
Making of proper section & isolation at existing 11 KV line for bifurcation of load.
A. A. ENGINEERING CO.
DEEPAK ENGINEERING
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .