Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC VIVEKA HOME 207 D UDANGUDI ROAD TISAYANVILLAI 627657 TIRUNELVELI | TISAYANVILLAI | TIRUNELVELI | TAMIL NADU | 627657 | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.8 L+₹1.5 L (3.41%)Rejected-Finance | L2 | Rejected-Finance being high bid value rejected | |
| 3 | L3₹47.6 L+₹2.3 L (5.07%)Rejected-Finance ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L3 | Rejected-Finance being high bid value rejected | |
| 4 | L4₹48.7 L+₹3.4 L (7.61%)Rejected-Finance CHENNAI | L4 | Rejected-Finance being high bid value rejected | |
| 5 | L5₹48.9 L+₹3.6 L (7.89%)Rejected-Finance | L5 | Rejected-Finance being high bid value rejected |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
10 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8196
2022_MES_501168_1
GE/TVL/8196
Open Tender
Miscellaneous Works
Item Rate
180 days
Vijayanarayanam and Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹90,000
Yes
24 Mar 2022
12 Jan 2022
12 Feb 2022
12 Jan 2022
10 Feb 2022
28 Jan 2022
12 Jan 2022 - 19 Jan 2022
60 days
Amount
SCHEDULE 'A' PART-I [ B/R WORKS]
Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified .
M&L plain cement concrete type D2, 1:4:8, 100mm thick in sub base of floor finished even and rough to receive top layer complete all as specified and directed.
Material & Labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Material and labour for coloured machine pressed precast concrete interlocking paver block, any shape and size of 60 mm thickness M-35 grade conforming to IS 15658-2006 with grey cement and pigment complete all as specified and as directed. Note :Colour & Pattern of interlocking paver blocks to be approved by GE.
Material and Labour for Chequered cement concrete tile 200mm x 200mm x 25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over and including cement mortar bedding 20mm thick in CM 1 : 6 complete all as specified and directed.
Material and Labour for PCC coping 1 : 2 : 4 type B-1 (using 20mm graded stone aggregate) cast in situ as in coping and weathering, slightly rounded or chamfered angles and throating etc including necessary form work complete all as specified and directed.
Supply and fix glass dividing strips 38 x 3mm thick complete all as specified and directed.
Material and Labour for 50mm thick plain cement concrete type B1, 1 : 2 : 4, (using 20mm graded aggregate) finished even and fair without using extra cement complete all as specified and directed.
Material and Labour for 50 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for Forming construction joint 30mm deep x 10mm wide and filled with sealing compound grade 'A' complete all as specified and as directed.
Demolition of brick work or stone / boulder masonry, built in cement or lime mortar including all quoints, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete.
M&L Brick work with sub class 'B' old size built in CM 1 : 6, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed.
M&L for rendering 15mm thick in two coats on brick or concrete surfaces in CM 1:4 on fair faces of brick work or concrete surfaces of wall finished even and smooth (without using extra cement) complete all as specified and as directed.
Demolition of Reincorced concrete in any position, manhole covers, drain covers, septic tank slabs etc & disposal of subbish off the premises complete all as specified and directed.
M&L for providing precast cement concrete in 1:2:4 type B-1 using 20mm graded stone aggregate as in drain cover slab, manhole cover slab etc set in CM 1:6 including necessary formwork complete all as specified and as directed.
Material and Labour for TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping ,for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Cleaning & removing all scale and dirt, from tanks of capacity exc 250 & not exc 500 ltrs from mouths of circulating pipes etc., including writing words (date of cleaning on ......)with wite paint n. exe 50mm height complete all as specified and as directed.
Cleaning & removing all scale and dirt, from tanks of capacity exc 500 & not exc 1000 ltrs from mouths of circulating pipes etc., including writing words (date of cleaning on ......)with wite paint n. exe 50mm height complete all as specified and as directed.
Cleaning & removing all scale and dirt, from tanks of capacity exc 1000 & not exc 2000 ltrs from mouths of circulating pipes etc., including writing words (date of cleaning on ......)with wite paint n. exe 50mm height complete all as specified and as directed.
Cutting / uprooting any type of trees/ plants over RCC roof / facia etc and after uprooting the area treated with spreading deweeding chemical and area making good by using PCC 1:2:4 (using 12.5mm garaded stone aggregate) and finished to match with adjoining surface etc complete all as specified and as directed.
S&F in repairs 20mm dia Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 25mm dia Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Dismantling old water storage tank and S & F new rotational moulded polyethylene water storage tanks 500 ltrs capacity, double layered ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Dismantling old water storage tank and S & F new rotational moulded polyethylene water storage tanks 1000 ltrs capacity, double layered ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Taking up or down steel tubing 20 mm bore including connections, cleaning for refixing or removal to store complete all as directed.
Taking up or down steel tubing 25 mm bore including connections, cleaning for refixing or removal to store complete all as directed.
Supplying and fixing or laying 20mm dia CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed
Supplying and fixing or laying 25mm dia CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed
Supply and Lay galvanised iron tubing medium grade 20 mm bore with all necessary fittings, cutting thread and laid in trenches/floor all as specified and as directed.
Supply and Lay galvanised iron tubing medium grade 25 mm bore with all necessary fittings, cutting thread and laid in trenches/floor all as specified and as directed.
Fixing only galvanised iron tubing medium grade 20 mm bore with all necessary fittings, cutting thread and laid in trenches/floor all as specified and as directed.
Fixing only galvanised iron tubing medium grade 25 mm bore with all necessary fittings, cutting thread and laid in trenches/floor all as specified and as directed.
Supply and fix in repairs Gun metal, globe or gate valve 20 mm dia with iron wheel head Screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fix in repairs Gun metal, globe or gate valve 25 mm dia with iron wheel head Screwed both ends for iron pipe and fixed complete all as specified and as directed.
Removal of existing road sign board stickers and clean the surface and Supply and fixing over the existing board with white colour retro reflective sticker (3M 1st quality) over the retro reflective sticker 1st quality of approved colour film (Blue /green) with letter, symbols and borders etc complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as directed.
Supply and fix framed work such as grills , grating ,etc with ends of bars shouldered and or revated for forged in to spike ,framed uard bars barred iron doors , ladders,balusters,walk ways raling framed work for water tanks similar work confirming to Fe -290 Gde E-165 complete all as specified and directed.
M&L for prepration of new steel surface of any description exc 10cm in with or girth and applying two coats of synthetic enamel paint over a coat of rex oxide primer complete all as specified and directed.
SCHEDULE 'A' PART-II [ E/M WORKS]
Supply ,lay and testing LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables: armoured multistranded heavy duty electric cable with aluminium conductor 3.5 Core 185 Sqmm laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables complete all as directed & as specified and as directed by Engineer-in-charge.
Description all as per item No 41 but 3.5 core 95 Sqmm size complete all specified and as directed.
Description all as per item No 41 but 3.5 core 70 Sqmm size complete all specified and as directed.
Description all as per item No 41 but 3.5 core 50 Sqmm size complete all specified and as directed.
Description all as per item No 41 but 3.5 core 35 Sqmm size complete all specified and as directed.
Supply and laying GI tubing Light grade of size 80 mm dia bore laid in trenches / on floors / walls/ceiling for protection of UG cable complete all as specified and as directed.
Supply and laying GI tubing Light grade of size 50 mm dia bore laid in trenches / on floors / walls/ceiling for protection of UG cable complete all as specified and as directed.
Earthing complete with GI earth plate 600mmX600mm x 6 mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts and washers of GI earthing strip protected by GI pipe i.e. light grade 40mm dia all as shown in electric plate No.3 of MES SSR Part I connected to earthing test point, testing complete including necessary earth pit PCC 1: 3: 6 chamber and 50mm thick PCC 1 : 2: 4 chamber cover and with 6mm dia mild steel re-enforcement of 10Cm C/L spacing both ways in lieu of CI cover refilling of soil ncluding taking down old complete Earthing system etc complete all as directed by Engineer-in-Charge. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth plate etc., complete
Earthing complete with copper earth plate electrode of size 60cmx60cmx3 mm thick bured directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the copper strip by means of bolts, nuts check nuts and washers of galvanized iron or steel using copper strip 25X3 mm as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40 mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 80mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs, etc, mest, charcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable earth plate complete all as specified & directed by Engr-in-Charge.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip specified and directed.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip all as specified and directed.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 400 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 350 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 250 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 200 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 160 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 100 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 36 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Plain cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in foundation etc complete all as specified and directed.
Material and Labour for PCC coping 1 : 2 : 4 type B-1 (using 20mm graded stone aggregate) as in coping etc finished even and fair without using extra cement including necessary form work complete all as specified and directed.
M&L for angle iron/MS plate including nuts,bolts,washers, welding,drilling holes for bolts in any shape or size as indicated or directed of making staging of the panel and painting with one coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint all as specified and directed.
S&F in reapairs digital multifunctional meter CT operated of range 0-200 A as required complete all as specified & as directed.
S&F LED indicating lamp suitable for LT panel complete all as specified & as directed.
S&F in repairs CT 200/5 A suitable for LT panel complete all as specified & as directed.
Supply installation, commissioning and testing of factory made out door LT distribution panel board cubical type Pedastal mounted type CPRI approved fabricated out door of MS 3.15 mm thick and angle iron 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chambere size of PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following all as specified and directed including removing the old unserviceable:- INCOMING:- (a) MCCB 4 Pole 400 Amp, 50 Hz, 415 V with rupturing capacity 50 KA- (01 Nos) OUT GOING:- (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. (01 Nos) (b) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA- (01 Nos) (c) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door LT distribution panel board cubical type pedastal type mounted CPRI approved fabricated out door of MS 3.15 mm thick and angle iron 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chambere size of PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following all as specified and directed including removing the old unserviceable :- INCOMING:- (a) MCCB 4 Pole 320 Amp, 50 Hz, 415 V with rupturing capacity 50 KA- (01 Nos) OUT GOING:- (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA-(01 Nos) (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA- (04 Nos) (c) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA- (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply and fix in repairs LT feeder pillar box with complete dismantling of burntout cable connections, bus-bars, MCCBs etc & painting to inernal/external surfaces with one coat of stnthetic enamel paint of approved grade, refixing of bus-bars, replacement of epoxy cast busbar insulators, serviceable MCCBs, all cable connection from busbar to terminals at both ends etc. including patch repair with electric welding for replacement of hinges, refixing of broken doors, replacement of locking arrangement with sliding bolts incl PCC for reconstruction of foundation/coping etc. all as specified & as directed. ( NOTE : MCCBs required for replacement & required PCC for reconstruction of foundation/coping/Angle iron will be measured & paid separately under respective items of this schedule.)
Taking down old rusted panel and Supply installation, commissioning and testing in repair of factory made out door LT distribution panel board cubical type pedestal mounted CPRI approved fabricated of size approx 1.2x1.4x0.6 Mtr, out door type made up of MS 3.15 mm thick and support angle iron 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber with colour coding sleeves of PVC insulated for connection with incoming and outgoing breakers complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer, LED indicating lamp 01 Set and LED Multifunction meter01 No providing space to accomodate the following incoming and out going MCCBs all as complete specified and directed. (a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. As I/Comer (01 No) (b) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. As O/going (01 Nos) (c) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. As O/going (02 Nos) (d) MCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA. As O/going (02 Nos) (e) Timer switch and ML-3 Contactor-01 No Note : 1. Old Serviceable MCCB will be fixed and cost deemed to be included in the unit quoted rate.2. wiring of MCCB and meters included in the unit quoted rate.3. Necessary GA drawing to be approved from accepting officer before ordering the Panel.4. Disconnection and reconnecting the cable after errection of panel shall be deemed to be included in the quoated rate.5. Required PCC for reconstruction of foundation/coping/Angle iron will be measured & paid separately under respective items of this schedule.
Taking down old rusted panel and Supply installation, commissioning and testing in repair of factory made out door LT distribution panel board cubical type pedestal mounted CPRI approved fabricated of size approx 1.2x1.4x0.6 Mtr, out door type made up of MS 3.15 mm thick and support angle iron 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber with colour coding sleeves of PVC insulated for connection with incoming and outgoing breakers complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer, LED indicating lamp 01 Set and LED Multifunction meter01 No providing space to accomodate the following MCCBs all as complete specified and directed. (a) MCCB 4 Pole 320 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. As I/Comer (01 No) (b) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. As O/going (02 Nos) (c) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. As O/going (02 Nos) (d) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. As O/going (02 Nos) (e) MCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA. As O/going (02 Nos) (f) Timer switch and ML-3 Contactor-01 No Note : 1. Old Serviceable MCCB will be fixed and cost deemed to be included in the unit quoted rate.2. wiring of MCCB and meters included in the unit quoted rate.3. Necessary GA drawing to be approved from accepting officer before ordering the Panel.4. Disconnection and reconnecting the cable after errection of panel shall be deemed to be included in the quoated rate.5. Required PCC for reconstruction of foundation/coping/Angle iron will be measured & paid separately under respective items of this schedule.
Supply and fix in repairs street light distrubution panel board with analog timer switch and with contactor ML-3 type, 40 Amps 3 pole MCB 230 volts, including taking down old UNSV items all as specified and directed
M&L plain cement concrete type D2, 1:4:8 (40mm aggregate), as in foundation complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes etc and getting out in hard/dense soil, complete all as specified
Returning, filling in incl spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all specified and as directed.
Removing excavated material to a distance n.exc 50 M and depositing where directed at a level n.exc 1.5 M above the starting point complete all specified and as directed.
M & L for spreading of approved sand for cable cushioning on top and bottom of cable as specified.for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
Supply and lay burnt bricks for cable protection of sub class 'B' standard size in trenches all as specified and directed.
PHEJAYS AGENCIES
JR ENTERPRISES
VVM CONSTRUCTIONS
AnnaiEnterprises
sri manikandan enterprises
MURUKAN BUILDERS
SUPER COOL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .